HBDV7 Series Direct Vent Gas Fireplace | CLEARANCES |
Clearances to combustibles
WARNING
Follow these instructions carefully to ensure safe installation. Failure to follow instructions exactly can create a fire hazard.
The appliance cannot be installed on a carpet, tile or other combustible material other than wood flooring. If installed on carpet or vinyl flooring, the appliance shall be installed on a metal, wood or noncombustible material panel extending full width and depth of the appliance.
Ceiling
| Combustible | Mantel |
|
| |
71” |
|
|
Minimum | 12” |
|
| Minimum |
|
NOTE: All mantel shelves, regard-
less of depth, should be a mini- mum of 12” from top of fireplace. Wall
Mantel shelf shall not exceed 12” maximum depth at 12” minimum
height from opening.
12”
12”
12”
Max.
Top of Exhaust ![]()
Louvers
Side View
Stud
Insulation
Board
Standoff
FP2581
Min. 4”
From Either
Side Wall
Figure 4 -
Clearances
FP2580
MANTEL CLEARANCES
NOTE: The combustible area above the facing must not protrude more than 3/4" from the facing. If it does, it is considered a mantel and must meet the mantel requirements listed in this manual.
WARNING | Never obstruct or modify the air inlet or |
| |
| outlet grilles (louvers). This may create a |
| fire hazard. |
|
|
|
| Combustible |
|
|
| Material Area |
|
|
| Wall |
|
FP2582 | 1" 156O” |
| |
|
| ||
| 256O” | 256O” |
|
|
| 45° | |
| 3" |
| |
Side of Fire- |
|
| |
place Opening |
| 4" |
|
| Top View |
| |
Figure 5 -
Mantel Clearances
54D8000