HBDV7 Series Direct Vent Gas Fireplace | CLEARANCES |
Clearances to combustibles
WARNING
Follow these instructions carefully to ensure safe installation. Failure to follow instructions exactly can create a fire hazard.
The appliance cannot be installed on a carpet, tile or other combustible material other than wood flooring. If installed on carpet or vinyl flooring, the appliance shall be installed on a metal, wood or noncombustible material panel extending full width and depth of the appliance.
Ceiling
| Combustible | Mantel |
|
| |
71” |
|
|
Minimum | 12” |
|
| Minimum |
|
NOTE: All mantel shelves, regard-
less of depth, should be a mini- mum of 12” from top of fireplace. Wall
Mantel shelf shall not exceed 12” maximum depth at 12” minimum
height from opening.
12”
12”
12”
Max.
Top of Exhaust
Louvers
Side View
Stud
Insulation
Board
Standoff
FP2581
Min. 4”
From Either
Side Wall
Figure 4 -
Clearances
FP2580
MANTEL CLEARANCES
NOTE: The combustible area above the facing must not protrude more than 3/4" from the facing. If it does, it is considered a mantel and must meet the mantel requirements listed in this manual.
WARNING | Never obstruct or modify the air inlet or |
| |
| outlet grilles (louvers). This may create a |
| fire hazard. |
|
|
|
| Combustible |
|
|
| Material Area |
|
|
| Wall |
|
FP2582 | 1" 156O” |
| |
|
| ||
| 256O” | 256O” |
|
|
| 45° | |
| 3" |
| |
Side of Fire- |
|
| |
place Opening |
| 4" |
|
| Top View |
|
Figure 5 -
Mantel Clearances
54D8000