Monessen Hearth HBDV400N/PSC7, HBDV300N/PV7, HBDV400N/PV7 Product Specifications, High Elevations

Page 5

PRODUCT FEATURES and GAS SPECIFICATIONS

HBDV7 Series Direct Vent Gas Fireplace

PRODUCT SPECIFICATIONS

This appliance has been certified for use with either natural or propane gas. Refer to appropriate data plates.

This appliance is not for use with solid fuels.

The appliance is approved for bedroom or bedsitting room installations.

The appliance must be installed in accordance with local codes if any. If none exist use the current installation code. ANSI Z223.1/NFPA 54 in the USA, CSA B149 in Canada.

This appliance is mobile home approved.

The appliance must be properly connected to a venting system.

The appliance is not approved for closet or recessed installations.

Hi/Lo Knob

 

Off/Pilot/On Knob

 

On/Off/RS Switch

FP2580

 

Ignitor

Optional Remote

Figure 1 -

Receiver

Blower Control

HBDV300/400 Fireplace

 

HIGH ELEVATIONS

Input ratings are shown in BTU per hour and are certified without deration for elevations up to 4,500 feet (1,370 m) above sea level.

For elevations above 4,500 feet (1,370 m) in USA, installation must be in accordance with the current ANSI Z223.1/NFPA 54 and/or local codes having juris- diction.

In Canada, please consult provincial and/or local authorities having jurisdiction for installation at eleva- tions above 4,500 feet (1,370 m).

GAS pressures

 

Natural

Propane (LP)

Inlet Minimum

4.5” w.c.

11.0” w.c.

Inlet Maximum

10.5” w.c.

13.0” w.c.

Manifold Pressure

3.5” w.c.

10.0” w.c.

Gas Specifications & ORIFICE SIZE

 

 

Max.Input

Min. Input

Orifice

Model

Fuel

BTU/h

BTU/h

Size

HBDV300NV7

Nat.

23,000

16,000

2.35 mm

HBDV300PV7

LP

23,000

18,000

1.50 mm

HBDV400NV7

Nat.

27,000

19,000

#41

HBDV400PV7

LP

26,000

20,000

1/16

HBDV300NSC7

Nat.

23,000

16,000

2.35 mm

HBDV300PSC7

LP

23,000

18,000

1.50 MM

HBDV400NSC7

Nat.

27,000

19,000

#41

HBDV400PSC7

LP

26,000

20,000

1/16

 

 

 

 

 

Before You Start

Read this homeowner manual thoroughly and follow all instructions carefully. Inspect all contents for shipping damage and immediately inform your dealer if any damage is found. Do not install any unit with damaged, incomplete, or substitute parts. Check your packing list to verify that all listed parts have been received. You should have the following:

Fireplace (Firebox and Burner System)

Rock Wool

Log Set

Items Required For Installation

Phillips Screwdriver

Framing Materials

Hammer

Wall Finishing Materials

Saw and/or saber saw

Level

Electric Drill and Bits

Tee Joint

Pliers

Measuring Tape

Square

Pipe Wrench

Caulking Material (Noncombustible)

Fireplace Surround Material (Noncombustible)

Piping Complying with Local Codes

Pipe Sealant Approved for use with Propane/LPG (Resistant to Sulfur Compounds)

54D8000

Image 5
Contents HBDV7 Series Direct Vent Gas Fireplace Massachusetts Residents Only Pre-Installation InformationCheck Gas Pressure Signature Command System Owner Important Safety InformationInstaller Never connect unit to private non Please Read the Following CarefullyKnown as wellhead gas Code ApprovalHigh Elevations Product SpecificationsHBDV300 HBDV400 Framing DimensionsFirebox framing PRE-INSTALLATION InformationFireplace Location Cold Climate InsulationMantel Clearances Clearances to combustiblesNever obstruct or modify the air inlet or Outlet grilles louvers. This may create aFinishing Material Secure Fireplace to Floor or FramingOptional TOP Vent Application Optional top vent applicationGeneral Venting Venting Installation InformationInstallation precautions General Venting Information Termination Location Canadian Installations1 US Installations2Termination Clearances USA InstallationsCanadian Installations Refer to Page 21 for requirements for snorkels How to Use the Vent GraphTwist Lock Pipes 1219 mm Vent InstallationStep Rear Wall Vent Installation Twist Lock PipeRear Wall Vent Application Top vent Sidewall Application Rear Wall Vent Installations Flex Vent PipeVent configurations apply and must be strictly adhered to + B = 17 Max Always install horizontal venting on a level plane Venting InstallationVertical Sidewall Installation Twist Lock Pipe Install the 4 flex then 7 flex to the termination Vertical Sidewall installation flex vent pipeDo not back fill around snorkel Below Grade InstallationsVertical THROUGH-THE-ROOF APPLICA- Tion Vertical THROUGH-THE-ROOF Installation Roof Flashing Check gas type Install gas piping to fireplace / burner system locationPropane/LP Fireplace InstallationNatural Gas Electrical Wiring Millivolt Check GAS Pressure and Electrical installationDo not use open flame to check for gas LeaksRemote Wall mounted Switch Electrical InstallationRemote Wall Switch Optional DC Remote SystemsNever use an open flame to check for gas leak What to do if YOU Smell GASInitial lighting Operating Instructions Millivolt Approved leak testing methodNever check for gas leak with open FlamePilot position Main burner switchLighting the burner Electrician. Main power must be off when Optional Accessory RequirementsConnecting to main electrical power supply Or performing service. All wiring shall beWall Switch Installation Junction BOX WiringCommand Center Wall Installation Nected together if a wall switch is not Being used Blotsc Signature Command Blower FK-12 Manual Blower Optional FAN Blower SystemsBlot Automatic Thermostat Blower On next Command Center Operating Instructions Signature CommandCommand Center FeaturesBattery Installation Function Operation Default Setting Key Combinations for System SettingsSelf Diagnostics Chart Command Center OperationsFUNCTIONS/OPERATION Function OperationGlass Frame Removal Brick installationGlass Removal Do not sprinkle the lava rock or ember Placement of Lava ROCK, Rock Wool and LogsPotential sooting, glass breakage and a fire HazardFinal Installation Left Front Log #6 Installing Universal Andirons Burner, Pilot and Control Compart- ment Glass Door Vent SysteMLogs Rock woolStanding Pilot Ignition Symptom Possible Cause ActionTroubleshooting Signature Command System Firebox Components Replacement PartsDescription Qty Firebox componentsStanding Pilot Millivolt Control LP to Natural Gas AccessoriesFuel Conversion Kits Natural Gas to LP Signature Command System HBDV300NSC7 HBDV300PSC7 HBDV400NSC7 HBDV400PSC7 Description Qty Replacement PartsLogs Description Model Number Vertical Venting7TBLSCTK Horizontal VentingHBDV7 Series Direct Vent Gas Fireplace HBDV7 Series Direct Vent Gas Fireplace Carbon Monoxide Detector Requirements Five Year Warranty Lifetime WarrantyBasic Warranty If Warranty Service is NeededModel EnerGuide Ratings Fireplace Efficiency % Mhsc