Monessen Hearth HBDV300N/PV7 Functions/Operation, Command Center Operations, Function Operation

Page 40

HBDV7 Series Direct Vent Gas FireplaceSIGNATURE COMMAND SYSTEM OPERATION INSTRUCTIONS

FUNCTIONS/OPERATION

Turning on the fireplace

1.Turn on the master switch and wait for a beep.

2.Press the ON button on the Command Center or turn on wall switch. Pilot will light and burner will come on High set- ting or last memory setting (See Turning Off Fireplace below). For memory feature.

Pilot Safety Lockout Function

1.If the pilot doesn’t light after sparking for 30 seconds, pilot trial lockout happens. The LED on the Command Center flashes Green once every 2 seconds, until reset.

2.If the pilot flame is lost during normal operation, the system will try three (3) times to relight after three (3) failures, flame loss lockout happens. The LED on the Command Center flashes Red-Green once every 2 seconds, until re- set.

3.Turning the master switch on the Command Center to the off position, then ON again will reset the system.

Flame Height Control

1.Press the ON button (on the Command Center) once to turn on the main burner with maximum flame height.

2.Press the OFF button to decrease flame height. The first two presses will decrease the flame height to medium and low.

3.The third press on OFF will turn off the main burner. In standing pilot configuration, the pilot will stay; in intermittent pilot configuration, the pilot will be shut off.

Turning the Fireplace Off

There are three ways to turn the fireplace off.

1.Flip the master switch to the off (“O”) position. (This will turn the entire system OFF.)

2.Press the OFF button to Medium, Low, then Off.

3.Hold the OFF button anytime for three seconds or by turning off the wall switch. These two commands of OFF are (Memory Off) the system will remember all last settings before turning off. The next time the fireplace is turned on, all settings will resume. To reset, change to the desired settings and shut off by using the Memory Off commands and the system will be reset to those new settings.

Command Center Operations:

The following functions are available on the Command Center.

Function

operation

Power Up

Flip the master switch to the ON ("_") position to power up the system

Fireplace ON

Press the ON button on the Command Center or turn on wall switch to turn the fireplace on

Fireplace OFF

Flip the master switch to the OFF ("o") position OR press the OFF button 3

 

times OR for Memory Off, hold the OFF button 3 seconds, or turn off wall switch

Flame Height Up

Press the ON button once to turn on the fireplace with maximum flame height

Flame Height Down

Press the OFF button to lower the flame height to Medium and Low

 

 

Self Diagnostics Chart:

The Command Center has a self-diagnostic LED enabling you to troubleshoot problems and potentially avoid a ser- vice call. Please refer to the charts below for indicator reference.

Fault

leD Indication

Conversion Cover Missing

One RED (1 time)

Spark Fail

Two RED (1 time)

No Sensor Signal

Three RED (1 time)

Pilot Lockout - trial

One GREEN, every 2 sec. (until manual reset)

Pilot Lockout - flame loss

One RED-GREEN, every 2 sec. (until manual reset)

Low Battery

One RED, every 10s (continuously)

No or Low Thermopile Power

Two RED, every 10s (continuously)

Learning

GREEN Flashes, every 1 sec. (for 10 sec.)

AC Power On

GREEN solid

Pressure Switch Failed (Power Vent only)

One RED every 2 sec. (until manual reset)

 

 

40

54D8000

Image 40
Contents HBDV7 Series Direct Vent Gas Fireplace Check Gas Pressure Signature Command System Pre-Installation InformationMassachusetts Residents Only Installer Important Safety InformationOwner Please Read the Following Carefully Never connect unit to private nonKnown as wellhead gas Code ApprovalProduct Specifications High ElevationsFraming Dimensions HBDV300 HBDV400PRE-INSTALLATION Information Firebox framingFireplace Location Cold Climate InsulationClearances to combustibles Mantel ClearancesNever obstruct or modify the air inlet or Outlet grilles louvers. This may create aSecure Fireplace to Floor or Framing Finishing MaterialOptional top vent application Optional TOP Vent ApplicationInstallation precautions Venting Installation InformationGeneral Venting Canadian Installations1 US Installations2 General Venting Information Termination LocationCanadian Installations USA InstallationsTermination Clearances Twist Lock Pipes How to Use the Vent GraphRefer to Page 21 for requirements for snorkels Vent Installation 1219 mmRear Wall Vent Application Rear Wall Vent Installation Twist Lock PipeStep Vent configurations apply and must be strictly adhered to Rear Wall Vent Installations Flex Vent PipeTop vent Sidewall Application + B = 17 Max Vertical Sidewall Installation Twist Lock Pipe Venting InstallationAlways install horizontal venting on a level plane Vertical Sidewall installation flex vent pipe Install the 4 flex then 7 flex to the terminationVertical THROUGH-THE-ROOF APPLICA- Tion Below Grade InstallationsDo not back fill around snorkel Vertical THROUGH-THE-ROOF Installation Roof Flashing Install gas piping to fireplace / burner system location Check gas typeNatural Gas Fireplace InstallationPropane/LP Millivolt Check GAS Pressure and Electrical installation Electrical WiringDo not use open flame to check for gas LeaksElectrical Installation Remote Wall mounted SwitchRemote Wall Switch Optional DC Remote SystemsInitial lighting What to do if YOU Smell GASNever use an open flame to check for gas leak Approved leak testing method Operating Instructions MillivoltNever check for gas leak with open FlameLighting the burner Main burner switchPilot position Optional Accessory Requirements Electrician. Main power must be off whenConnecting to main electrical power supply Or performing service. All wiring shall beCommand Center Wall Installation Junction BOX WiringWall Switch Installation Nected together if a wall switch is not Being used Blotsc Signature Command Blower Blot Automatic Thermostat Blower Optional FAN Blower SystemsFK-12 Manual Blower On next Operating Instructions Signature Command Command CenterBattery Installation FeaturesCommand Center Key Combinations for System Settings Function Operation Default SettingCommand Center Operations Self Diagnostics ChartFUNCTIONS/OPERATION Function OperationGlass Removal Brick installationGlass Frame Removal Placement of Lava ROCK, Rock Wool and Logs Do not sprinkle the lava rock or emberPotential sooting, glass breakage and a fire HazardFinal Installation Left Front Log #6 Installing Universal Andirons Burner, Pilot and Control Compart- ment Vent SysteM Glass DoorLogs Rock woolSymptom Possible Cause Action Standing Pilot IgnitionTroubleshooting Signature Command System Replacement Parts Firebox ComponentsFirebox components Description QtyStanding Pilot Millivolt Control Fuel Conversion Kits Natural Gas to LP AccessoriesLP to Natural Gas Signature Command System HBDV300NSC7 HBDV300PSC7 HBDV400NSC7 HBDV400PSC7 Logs Replacement PartsDescription Qty Vertical Venting Description Model NumberHorizontal Venting 7TBLSCTKHBDV7 Series Direct Vent Gas Fireplace HBDV7 Series Direct Vent Gas Fireplace Carbon Monoxide Detector Requirements Lifetime Warranty Five Year WarrantyBasic Warranty If Warranty Service is NeededMhsc Model EnerGuide Ratings Fireplace Efficiency %