TROUBLESHOOTING

SIGNATURE COMMAND SYSTEM

OPERATIONFAULT

 

DIAGNOSIS

 

 

ACTION

 

Using

 

 

 

 

 

 

 

 

 

Battery polarity wrong?

 

 

Re-install batteries

 

 

 

 

battery?

 

 

 

 

Make sure

 

 

 

 

 

 

 

 

Install batteries and/or plug in the AC board

Flip the master switch (rocker switch) to the ON position

After the beep

Press the ON button on the Command Center

No beep in about 8 seconds

No beep

or

no sound from the valve indicating pilot solenoid open

No sparking on the pilot

Sparking doesn’t continue

Pilot doesn’t light

Main burner doesn’t light

 

Command

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Battery voltage low?

 

 

 

 

 

Change batteries

A

Center and

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

the control

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

board are

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

connected by

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

a 2 feet or 15

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AC plug is plugged to

 

 

 

 

 

Plug the AC plug to

 

feet cable

 

 

 

 

 

 

 

 

 

AC mains?

 

 

 

 

 

 

 

 

AC mains

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The 5-pin connector on

 

 

 

 

 

Repair or replace the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

the AC board broken or

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AC Board

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

bent?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LED on the Command

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Replace the AC Board

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Center does not show

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

solid green?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Check NG/LP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Check power

 

 

 

Replace the Control

 

 

 

 

 

 

 

Check valve

 

 

 

B

conversion cap

 

 

 

 

connections

 

 

 

supply (go

 

 

 

Board or

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

through A )

 

 

 

 

 

 

and control

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Command Center

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

board

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

connections

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Sparking is happening

 

Check pilot

 

 

Check

 

 

Go through

 

 

 

 

elsewhere (under the

 

 

connections

 

 

 

 

 

grounding

 

 

 

 

B

 

 

 

 

pilot), re-install/replace

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

the pilot

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D

The Control Board is having interference from the

 

 

 

 

 

Re-install the Control

 

 

 

 

 

 

Board, move it around

 

 

 

 

 

 

 

 

surrounding metal (Ground)

 

 

 

 

 

 

 

 

or change the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Control Board

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Sparking is not in the

 

Check gas supply

 

 

 

 

 

 

 

 

Go through

C

 

 

 

 

 

 

 

path of gas flow, adjust

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

sparker position or

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

replace the pilot

 

F

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Go through E

 

 

 

 

 

 

The sensor on the pilot

 

 

 

 

 

 

Adjust sensor position

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

is not in the flame

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

or replace the pilot

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(pilot flame too small)?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

50

54D8000

Image 50
Contents HBDV7 Series Direct Vent Gas Fireplace Massachusetts Residents Only Pre-Installation InformationCheck Gas Pressure Signature Command System Owner Important Safety InformationInstaller Known as wellhead gas Please Read the Following CarefullyNever connect unit to private non Code ApprovalProduct Specifications High ElevationsFraming Dimensions HBDV300 HBDV400Fireplace Location PRE-INSTALLATION InformationFirebox framing Cold Climate InsulationNever obstruct or modify the air inlet or Clearances to combustiblesMantel Clearances Outlet grilles louvers. This may create aSecure Fireplace to Floor or Framing Finishing MaterialOptional top vent application Optional TOP Vent ApplicationGeneral Venting Venting Installation InformationInstallation precautions Canadian Installations1 US Installations2 General Venting Information Termination LocationTermination Clearances USA InstallationsCanadian Installations Refer to Page 21 for requirements for snorkels How to Use the Vent GraphTwist Lock Pipes Vent Installation 1219 mmStep Rear Wall Vent Installation Twist Lock PipeRear Wall Vent Application Top vent Sidewall Application Rear Wall Vent Installations Flex Vent PipeVent configurations apply and must be strictly adhered to + B = 17 Max Always install horizontal venting on a level plane Venting InstallationVertical Sidewall Installation Twist Lock Pipe Vertical Sidewall installation flex vent pipe Install the 4 flex then 7 flex to the terminationDo not back fill around snorkel Below Grade InstallationsVertical THROUGH-THE-ROOF APPLICA- Tion Vertical THROUGH-THE-ROOF Installation Roof Flashing Install gas piping to fireplace / burner system location Check gas typePropane/LP Fireplace InstallationNatural Gas Do not use open flame to check for gas Millivolt Check GAS Pressure and Electrical installationElectrical Wiring LeaksRemote Wall Switch Electrical InstallationRemote Wall mounted Switch Optional DC Remote SystemsNever use an open flame to check for gas leak What to do if YOU Smell GASInitial lighting Never check for gas leak with open Approved leak testing methodOperating Instructions Millivolt FlamePilot position Main burner switchLighting the burner Connecting to main electrical power supply Optional Accessory RequirementsElectrician. Main power must be off when Or performing service. All wiring shall beWall Switch Installation Junction BOX WiringCommand Center Wall Installation Nected together if a wall switch is not Being used Blotsc Signature Command Blower FK-12 Manual Blower Optional FAN Blower SystemsBlot Automatic Thermostat Blower On next Operating Instructions Signature Command Command CenterCommand Center FeaturesBattery Installation Key Combinations for System Settings Function Operation Default SettingFUNCTIONS/OPERATION Command Center OperationsSelf Diagnostics Chart Function OperationGlass Frame Removal Brick installationGlass Removal Potential sooting, glass breakage and a fire Placement of Lava ROCK, Rock Wool and LogsDo not sprinkle the lava rock or ember HazardFinal Installation Left Front Log #6 Installing Universal Andirons Burner, Pilot and Control Compart- ment Logs Vent SysteMGlass Door Rock woolSymptom Possible Cause Action Standing Pilot IgnitionTroubleshooting Signature Command System Replacement Parts Firebox ComponentsFirebox components Description QtyStanding Pilot Millivolt Control LP to Natural Gas AccessoriesFuel Conversion Kits Natural Gas to LP Signature Command System HBDV300NSC7 HBDV300PSC7 HBDV400NSC7 HBDV400PSC7 Description Qty Replacement PartsLogs Vertical Venting Description Model NumberHorizontal Venting 7TBLSCTKHBDV7 Series Direct Vent Gas Fireplace HBDV7 Series Direct Vent Gas Fireplace Carbon Monoxide Detector Requirements Basic Warranty Lifetime WarrantyFive Year Warranty If Warranty Service is NeededMhsc Model EnerGuide Ratings Fireplace Efficiency %