Monessen Hearth HBDV400N/PV7, HBDV300N/PV7, HBDV400N/PSC7 Vertical THROUGH-THE-ROOF Installation

Page 22
FP2304
Figure 37 -
Vertical Through-the-Roof Restrictor

HBDV7 Series Direct Vent Gas Fireplace

VENTING INSTALLATION

Max.Height 40’ (12.2. m)

Min. Height

 

8’ (2.4 m)

Max. 10’ (3 m)

Support Straps

Every 3’ (914 mm)

Max.Height

Max. 10’ (3 m)

 

40’ (12.2. m)

 

Min. Height 8’ (2.4 m)

 

Figure 35 -

 

Support Straps for

 

Horizontal Runs

 

FP1183a

1 + 2 + 3 + 4 = 270°

 

1

1

2

2

3

3

4

4

 

VERTICAL THROUGH-THE-ROOF INSTALLATION

NOTE: For all top vent vertical through-the-roof instal- lations, install the supplied cross-bar flue restrictor, part #69D3006 onto the top edge of the firebox flue adapter. Figure 37

1.Locate your fireplace.

2.Plumb to center of the

(4”) flue collar from ceiling above and mark position.

3.Cut opening equal to 9C\v” x 9C\v” (248 x 248 mm).

4.Proceed to plumb for addi-

tional openings through the roof. In all cases, the open- ing must provide a mini- mum of 1 inch clearance to the vent pipe, i.e., the hole

must be at least 9C\v” x 9C\v” (248 x 248 mm).

5.Place fireplace into position.

6.Place firestop(s) or Attic Insulation Shield into position and secure. Figure 38

Attic Insulation Shield (7DV1AIS)

Upper Floor

11” (279 mm)

Ceiling Installation

FP1029

Joist

Figure 36 -

FP1179

 

Maximum Elbow Usage

 

7DVCS supports offsets. Figure 39. This application

Figure 38 -

Firestop

Spacer

Nails (4)

will require that you first determine the roof pitch and

use the appropriate starter kit. (Refer to Venting Com-

ponents List)

The maximum angular variation allowed in the system

is 270°. Figure 36

For the minimum height of the vent above the highest

point of penetration through the roof refer to Page 23,

Figure 40.

Place Firestop Spacer(s) and Secure

7.Install roof support (Figure 39) and roof flashing mak- ing sure upper flange is below the shingles. Figure 41

8.Install appropriate pipe sections until the venting is above the flashing. Figure 41

9.Install storm collar and seal around the pipe.

22

54D8000

Image 22
Contents HBDV7 Series Direct Vent Gas Fireplace Check Gas Pressure Signature Command System Pre-Installation InformationMassachusetts Residents Only Installer Important Safety InformationOwner Known as wellhead gas Please Read the Following CarefullyNever connect unit to private non Code ApprovalProduct Specifications High ElevationsFraming Dimensions HBDV300 HBDV400Fireplace Location PRE-INSTALLATION InformationFirebox framing Cold Climate InsulationNever obstruct or modify the air inlet or Clearances to combustiblesMantel Clearances Outlet grilles louvers. This may create aSecure Fireplace to Floor or Framing Finishing MaterialOptional top vent application Optional TOP Vent ApplicationInstallation precautions Venting Installation InformationGeneral Venting Canadian Installations1 US Installations2 General Venting Information Termination LocationCanadian Installations USA InstallationsTermination Clearances Twist Lock Pipes How to Use the Vent GraphRefer to Page 21 for requirements for snorkels Vent Installation 1219 mmRear Wall Vent Application Rear Wall Vent Installation Twist Lock PipeStep Vent configurations apply and must be strictly adhered to Rear Wall Vent Installations Flex Vent PipeTop vent Sidewall Application + B = 17 Max Vertical Sidewall Installation Twist Lock Pipe Venting InstallationAlways install horizontal venting on a level plane Vertical Sidewall installation flex vent pipe Install the 4 flex then 7 flex to the terminationVertical THROUGH-THE-ROOF APPLICA- Tion Below Grade InstallationsDo not back fill around snorkel Vertical THROUGH-THE-ROOF Installation Roof Flashing Install gas piping to fireplace / burner system location Check gas typeNatural Gas Fireplace InstallationPropane/LP Do not use open flame to check for gas Millivolt Check GAS Pressure and Electrical installationElectrical Wiring LeaksRemote Wall Switch Electrical InstallationRemote Wall mounted Switch Optional DC Remote SystemsInitial lighting What to do if YOU Smell GASNever use an open flame to check for gas leak Never check for gas leak with open Approved leak testing methodOperating Instructions Millivolt FlameLighting the burner Main burner switchPilot position Connecting to main electrical power supply Optional Accessory RequirementsElectrician. Main power must be off when Or performing service. All wiring shall beCommand Center Wall Installation Junction BOX WiringWall Switch Installation Nected together if a wall switch is not Being used Blotsc Signature Command Blower Blot Automatic Thermostat Blower Optional FAN Blower SystemsFK-12 Manual Blower On next Operating Instructions Signature Command Command CenterBattery Installation FeaturesCommand Center Key Combinations for System Settings Function Operation Default SettingFUNCTIONS/OPERATION Command Center OperationsSelf Diagnostics Chart Function OperationGlass Removal Brick installationGlass Frame Removal Potential sooting, glass breakage and a fire Placement of Lava ROCK, Rock Wool and LogsDo not sprinkle the lava rock or ember HazardFinal Installation Left Front Log #6 Installing Universal Andirons Burner, Pilot and Control Compart- ment Logs Vent SysteMGlass Door Rock woolSymptom Possible Cause Action Standing Pilot IgnitionTroubleshooting Signature Command System Replacement Parts Firebox ComponentsFirebox components Description QtyStanding Pilot Millivolt Control Fuel Conversion Kits Natural Gas to LP AccessoriesLP to Natural Gas Signature Command System HBDV300NSC7 HBDV300PSC7 HBDV400NSC7 HBDV400PSC7 Logs Replacement PartsDescription Qty Vertical Venting Description Model NumberHorizontal Venting 7TBLSCTKHBDV7 Series Direct Vent Gas Fireplace HBDV7 Series Direct Vent Gas Fireplace Carbon Monoxide Detector Requirements Basic Warranty Lifetime WarrantyFive Year Warranty If Warranty Service is NeededMhsc Model EnerGuide Ratings Fireplace Efficiency %