Jotul GF 100 DV II, GF 200 DV II manual Installation and Operation Instructions

Page 1

Installation and Operation Instructions

Jøtul GF 100 DV II Nordic QT

Jøtul GF 200 DV II Lillehammer

GF 100 DV II Nordic QT

GF 200 DV II Lillehammer

WARNING:

IF THE INFORMATION IN THESE INSTRUCTIONS ARE NOT FOLLOWED EXACTLY, A FIRE OR EXPLO- SION MAY RESULT CAUSING PROPERTY DAMAGE,

PERSONAL INJURY OR LOSS OF LIFE.

FOR YOUR SAFETY:

DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN THE VICIN- ITY OF THIS OR ANY OTHER APPLIANCE.

INSTALLATION:

INSTALLATION AND SERVICE MUST BE PER- FORMED BY A QUALIFIED INSTALLER, SERVICE AGENCY OR LICENSED GAS SUPPLIER.

THIS PRODUCT MUST BE INSTALLED BY A LICENSED PLUMBER OR GAS-FITTER WHEN INSTALLED IN THE COMMONWEALTH OF MASSACHUSETTS.

A CARBON MONOXIDE (CO) DETECTOR SHALL BE INSTALLED IN THE SAME ROOM AS THE APPLIANCE.

WHAT TO DO IF YOU SMELL GAS:

DO NOT TRY TO LIGHT ANY APPLIANCE.

DO NOT TOUCH ANY ELECTRICAL SWITCHES.

DO NOT USE THE PHONE IN YOUR BUILDING. IMMEDIATELY CALL YOUR GAS SUPPLIER FROM A NEIGHBOR’S PHONE.

FOLLOW YOUR GAS SUPPLIER’S INSTRUCTIONS.

IF YOU CANNOT REACH YOUR GAS SUPPLIER, CALL THE FIRE DEPARTMENT.

AVERTISSEMENT:

ASSUREZ-VOUS DE BIEN SUIVRE LES INSTRUC- TIONS DANS CETTE NOTICE POUR REDUIRE AU MINIMUM LE RISQUE D’INCENDIE OU POUR EVITER TOUT DOMMAGE MATERIEL, TOUTE BLESSURE OU MORTALIT’E.

NE PAS ENTREPOSER NI UTILISER D’ESSENCE NI OU LIQUIDES INFLAMMABLES DANS LE VOISINAGE DE CET APPAREIL OU DE TOUT AUTRE APPAREIL.

L’INSTALLATION LE SERVICE DOIVENT ETRE EXECUTES PAR UN INSTALLATEUR QUALIFIE, AGENCE DE SERVICE OU LE FOURNISSEUR DE GAZ.

QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ.

NE PAS TENTER D’ALLUMER L’APPAREIL

NE TOUCHEZ A AUCUM NTERRUPTEUR.

NE PAS VOUS SERVIR DES TELEPHONES SE TROUVANT DANS LE BATIMENT OU VOUS VOUS TROUVEZ.

APPELEZ IMMEDIATEMENT VOTRE FOURNISSEUR DE GAZ CHEZ UN VOISIN. SUIVEZ LES INSTRUC- TIONS DU FOURNISSEUR.

SI VOUS NE POUVEZ REJOINDRE LE FOURNISSEUR DE GAZ, APPELEZ LE SERVICE DES INCENDIES.

1

Image 1
Contents Installation and Operation Instructions Welcome to Jøtul Table of Contents GF 100 DV II Miscellaneous Kit Contents Jøtul GF 100 DV II Nordic QT SpecificationsGF 100 DV II Accessories Input RatesGF 200 DV II Miscellaneous Kit Contents Jøtul GF 200 DV II Lillehammer SpecificationsSuggested Tools for Installation and Service Stove SetupRemove the Top Plate Remove the Glass PanelLocation Safety InformationHearth Requirements Glass FrontAlcove Installation Intake Air Restriction Venting RequirementsHorizontal Termination Vertical TerminationHorizontal RUN Vertical Vent TerminationThese installation requirements must be followed Co-linear Vent InstallationVenting Through a Fireplace Min. / Max. Horizontal Run Horizontal Vent TerminationHorizontal Termination with Vertical Rise Wall Shield InstallationMin inches, U.S. / *12 inches 30 cm can Horizontal Termination ClearanceConversion Kit Contents Mobile Home InstallationTools required Never USE AN Open Flame to Check for GAS Leaks Gas Conversion ProcedureLeak test Gas Supply ConnectionGas Pressure High Altitude AdjustmentInches water column High Altitude Orifice Chart GF 200 DV II Only Flame Appearance Air Shutter AdjustmentDerating Procedure To adjust the air shutterLog Set Installation Optional Wall Thermostat or Remote ControlRemote Control Proper pilot flame appearance System CheckGlass and Gasket Replacement MaintenanceOnly Use Replacement Kit OperationDate of Purchase Name of InstallerOptional Blower # InstallationBlower Operation Connect power cord to the nearest outletAttach the Blower to the stove Snapstat terminal. See figs.3547a 47b 47a Parts List GF 100 DV II / GF 200 DV II Firebox Assembly47b GF 100 DV II Nordic QT GF 200 DV II Lillehammer GF 100 DV II Nordic QT Cast Iron Parts ListInstall the Lower Panel Optional Antique Brick Panel Kit InstallationInstall the Logset. Refer to pg Replace the Glass FrameControl Valve Lighting InstructionsJøtul North America Jøtul AS