Jotul GF 100 DV II, GF 200 DV II manual Vertical Vent Termination, Horizontal RUN

Page 10

GF 100 DV II Nordic QT GF 200 DV II Lillehammer

Vertical Vent Termination

The Jøtul GF 100 DV II and Jøtul GF 200 DV II are ap- proved for vertical venting through a ceiling or to a roof termination following these guidelines:

„The termination should fall within the shaded area of the grid depicted in fig.7 below.

Maximum Vertical must not exceed 15 ft. (4.57 m) measured from the top of the stove.

„In no case shall any discharge opening on the termi- nation cap be less than 18” (457 mm) horizontally from the roof surface. See fig. 8.

„In addition the 90° elbow attached to the stove, a vertical vent run may utilize one 90° or two 45° elbows. Whenever possible use 45° elbows instead of a 90° elbow as they are less restrictive to exhaust gas and intake air flow.

„Steep roofs, nearby trees, and predominantly windy conditions can contribute to poor draft and/or promote down-draft occurrences. Increasing the height of the vent may alleviate these conditions.

„Use approved vent manufacturer’s Wall Straps to support an offset pipe run at three feet intervals to avoid excessive stress on the offsets.

„A firestop is required at every floor. Firestops are available from all vent manufacturers. The opening should be framed to 10" X 10" inside dimension.

„Always maintain a minimum 1" clearance from all sides of the vertical vent system.

„Remove the Recirculator Plate from the back of the Burner Skirt as shown in fig. 5. Determine which Air Intake Restrictor plates should be used by following the guidelines on page 9.

15Ft.

(457.2 cm)

RUN

10 Ft.

 

 

 

VERTICAL

(305 cm)

5 Ft.

 

 

 

(152.4 cm)

4 Ft.

(121.9 cm)

HORIZONTAL RUN

ANY VENTING WITH A VERTICAL RISE MUST TERMINATE (END) WITHIN THE SHADED AREA.

MAXIMUM ELBOWS: TWO 90° OR ONE 90° AND TWO 45°.

ALWAYS MAINTAIN THE PROPER CLEARANCES TO COMBUSTIBLES.

Figure 7. Vent Termination Diagram - any termination must fall within the shaded area dimensions.

Horizontal Overhang

18”.

 

 

 

18”.

min.

 

 

 

min.

 

Lowest Discharge

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Opening

Termination

 

 

 

 

 

 

 

 

 

 

 

Cap

 

 

 

 

 

 

 

 

 

 

 

1

8” m

in.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 8. Minimum vertical termination height and roof clearance.

10

Image 10
Contents Installation and Operation Instructions Welcome to Jøtul Table of Contents GF 100 DV II Accessories Jøtul GF 100 DV II Nordic QT SpecificationsGF 100 DV II Miscellaneous Kit Contents Input RatesJøtul GF 200 DV II Lillehammer Specifications GF 200 DV II Miscellaneous Kit ContentsRemove the Top Plate Stove SetupSuggested Tools for Installation and Service Remove the Glass PanelHearth Requirements Safety InformationLocation Glass FrontAlcove Installation Horizontal Termination Venting RequirementsIntake Air Restriction Vertical TerminationVertical Vent Termination Horizontal RUNThese installation requirements must be followed Co-linear Vent InstallationVenting Through a Fireplace Horizontal Vent Termination Min. / Max. Horizontal RunWall Shield Installation Horizontal Termination with Vertical RiseHorizontal Termination Clearance Min inches, U.S. / *12 inches 30 cm canConversion Kit Contents Mobile Home InstallationTools required Gas Conversion Procedure Never USE AN Open Flame to Check for GAS LeaksGas Supply Connection Leak testGas Pressure High Altitude AdjustmentInches water column Derating Procedure Flame Appearance Air Shutter AdjustmentHigh Altitude Orifice Chart GF 200 DV II Only To adjust the air shutterLog Set Installation Optional Wall Thermostat or Remote ControlRemote Control System Check Proper pilot flame appearanceOnly Use Replacement Kit MaintenanceGlass and Gasket Replacement OperationName of Installer Date of PurchaseInstallation Optional Blower #Attach the Blower to the stove Connect power cord to the nearest outletBlower Operation Snapstat terminal. See figs.3547a 47b 47a Parts List GF 100 DV II / GF 200 DV II Firebox Assembly47b GF 100 DV II Nordic QT GF 200 DV II Lillehammer Cast Iron Parts List GF 100 DV II Nordic QTInstall the Logset. Refer to pg Optional Antique Brick Panel Kit InstallationInstall the Lower Panel Replace the Glass FrameLighting Instructions Control ValveJøtul AS Jøtul North America