Jotul GF 100 DV II, GF 200 DV II manual Jøtul GF 100 DV II Nordic QT Specifications, Input Rates

Page 4

GF 100 DV II Nordic QT

GF 200 DV II Lillehammer

Jøtul GF 100 DV II Nordic QT Specifications

Input Rates

Natural Gas

17,000 BTU/hr. maximum input

9,900 BTU/hr. minimum input

Propane

16,000 BTU/hr. maximum input

8,700 BTU/hr. minimum input

Inlet Pressure:

MIN

MAX

Natural Gas:

5.0 WC (1.24 kPa)

7.0 WC (1.74 kPa)

Propane:

12.0 WC (2.98 kPa)

14.6 WC (3.63 kPa)

Manifold Pressure:

MIN

MAX

Natural Gas:

1.2 WC (0.29 kPa)

3.8 WC (0.94 kPa)

Propane:

2.9 WC (0.72 kPa)

11.0 WC (2.74 kPa)

Piezo Ignitor / Standing Pilot

Weight: 150 lbs.

The Jøtul GF 100 DV II Nordic QT is a Direct Vent gas heater designed as a sealed combustion, air circulating gas appliance for residential applications. This appliance is approved for installation using

6 5/8" X 4" vent pipe from the following manufacturers: Simpson Dura-Vent GS

Security Vent, Ltd. Amerivent Inc. Selkirk Metalbestos

The Jøtul GF 100 DV II Nordic QT gas stove is designed to burn NATURAL GAS or PROPANE only. It is shipped from the factory equipped to burn Natural Gas. If use with Propane is desired, the stove must first be converted for use with that gas. Use the LP Fuel Conversion Kit 155628 included with this stove See page 14 for instructions.

20 5/8”

524 mm

22 1/4”

565 mm

18 1/4”

16 3/4 ”

464

425 mm

mm

 

Flue Collar

Centerline

16 3/4”

425 mm

Leg To

Leg

14”

356 mm

GF 100 DV II Miscellaneous Kit Contents

• Fuel Conversion Kit - LP

155628

Rear Air Intake Restrictor Plate, Black -22111092 or Jøtul Iron - 22111085

Side Air Intake Restrictor Plates, (2) ....

22099192

 

or Jøtul Iron - 22099185

*

Decorative Wall Shield, Black

22092692

 

or Jøtul Iron

22092692

GF 100 DV II Accessories

 

Blower Kit

155631

Antique Brick Kit

155815

Fuel Conversion Kit - NG

155629

Wall Thermostat

750003

Remote Control

129706

• Mobile Home Floor Bracket Kit

154342

4

Image 4
Contents Installation and Operation Instructions Welcome to Jøtul Table of Contents Jøtul GF 100 DV II Nordic QT Specifications GF 100 DV II Miscellaneous Kit ContentsGF 100 DV II Accessories Input RatesJøtul GF 200 DV II Lillehammer Specifications GF 200 DV II Miscellaneous Kit ContentsStove Setup Suggested Tools for Installation and ServiceRemove the Top Plate Remove the Glass PanelSafety Information LocationHearth Requirements Glass FrontAlcove Installation Venting Requirements Intake Air RestrictionHorizontal Termination Vertical TerminationVertical Vent Termination Horizontal RUNThese installation requirements must be followed Co-linear Vent InstallationVenting Through a Fireplace Horizontal Vent Termination Min. / Max. Horizontal RunWall Shield Installation Horizontal Termination with Vertical RiseHorizontal Termination Clearance Min inches, U.S. / *12 inches 30 cm canConversion Kit Contents Mobile Home InstallationTools required Gas Conversion Procedure Never USE AN Open Flame to Check for GAS LeaksGas Supply Connection Leak testGas Pressure High Altitude AdjustmentInches water column Flame Appearance Air Shutter Adjustment High Altitude Orifice Chart GF 200 DV II OnlyDerating Procedure To adjust the air shutterLog Set Installation Optional Wall Thermostat or Remote ControlRemote Control System Check Proper pilot flame appearanceMaintenance Glass and Gasket ReplacementOnly Use Replacement Kit OperationName of Installer Date of PurchaseInstallation Optional Blower #Connect power cord to the nearest outlet Blower OperationAttach the Blower to the stove Snapstat terminal. See figs.3547a 47b 47a Parts List GF 100 DV II / GF 200 DV II Firebox Assembly47b GF 100 DV II Nordic QT GF 200 DV II Lillehammer Cast Iron Parts List GF 100 DV II Nordic QTOptional Antique Brick Panel Kit Installation Install the Lower PanelInstall the Logset. Refer to pg Replace the Glass FrameLighting Instructions Control ValveJøtul AS Jøtul North America