Jotul GF 100 DV II, GF 200 DV II manual Jøtul GF 200 DV II Lillehammer Specifications

Page 5

Jøtul GF 200 DV II Lillehammer Specifications

Input Rates

Natural Gas

20,000 BTU/hr. maximum input

11,400 BTU/hr. minimum input

Propane

18,000 BTU/hr. maximum input

8,450 BTU/hr. minimum input

Inlet Pressure:

MIN

MAX

Natural Gas:

5.0 WC (1.24 kPa)

7.0 WC (1.74 kPa)

Propane:

12.0 WC (2.98 kPa)

14.6 WC (3.63 kPa)

Manifold Pressure:

MIN

MAX

Natural Gas:

1.2 WC (0.29 kPa)

3.8 WC (0.94 kPa)

Propane:

2.9 WC (0.72 kPa)

11.0 WC (2.74 kPa)

Piezo Ignitor / Standing Pilot

Weight: 180 lbs.

The Jøtul GF 200 DV II Lillihammer is a Direct Vent gas heater designed as a sealed combustion, air circulating gas appliance for residential applications. This appliance is approved for installation using

6 5/8" X 4" vent pipe from the following manufacturers: Simpson Dura-Vent GS

Security Vent, Ltd. Amerivent Inc. Selkirk Metalbestos

The Jøtul GF 200 DV II Lillehammer gas stove is designed to burn NATURAL GAS or PROPANE only.

It is shipped from the factory equipped to burn Natural Gas. If use with Propane is desired, the stove must first be converted for use with that gas. Use the LP Fuel Conversion Kit 155626 included with this stove See page 14 for instructions.

GF 200 DV II Miscellaneous Kit Contents

Fuel Conversion Kit - LP ................................ 155626

Rear Air Intake Restrictor Plate, Black -22111092 or Jøtul Iron - 22111085

Side Air Intake Restrictor Plates, (2) .... 22099192 or Jøtul Iron - 22099185

*Decorative Wall Shield, Black ................ 22092692 or Jøtul Iron..... 22092692

GF 100 DV II Nordic QT

GF 200 DV II Lillehammer

24 3/4”

630 mm

223/4” 560 mm

 

Leg To

17 1/4”

18 1/2”

Leg

470 mm

13”

438 mm

 

330 mm

 

24 3/4”

630 mm

 

 

21 1/8”

 

 

 

537 mm

As shipped

 

18 ”

 

 

 

with 6”

 

457 mm

 

(152 mm)

 

 

 

 

 

 

Legs

Height Dimensions with Optional Legs

Plinth Kit - subtract I” (25 mm)

Long Legs - add 2 1/4” (57 mm)

GF 200 DV II Accessories

 

Fuel Conversion Kit - NG

155627

High Altitude Adjustment Kit - NG

155808

High Altitude Adjustment Kit - LP

155809

Blower Kit

155631

Antique Brick Kit

155815

Wall Thermostat

750003

Remote Control

129706

Mobile Home Floor Bracket Kit .... GF 200 DV II (6”) / 154923

 

............................................................. for Long Legs (8”) / 750304

 

.......................................................................

for Plinth Kit / 154342

Long Leg Kits

Matte Black / 154929

 

..........................................................................

Blue Black / 154930

 

.....................................................................

Forest Green / 154931

 

..................................................................................

Ivory / 154932

 

.............................................................................

Jøtul Iron / 155366

Plinth Kits

Matte Black / 350081

 

..........................................................................

Blue Black / 350082

 

....................................................................................

Ivory / 350083

 

..................................................................

Forest Green / 350084

 

.............................................................................

Jøtul Iron / 350085

5

Image 5
Contents Installation and Operation Instructions Welcome to Jøtul Table of Contents GF 100 DV II Miscellaneous Kit Contents Jøtul GF 100 DV II Nordic QT SpecificationsGF 100 DV II Accessories Input RatesGF 200 DV II Miscellaneous Kit Contents Jøtul GF 200 DV II Lillehammer SpecificationsSuggested Tools for Installation and Service Stove SetupRemove the Top Plate Remove the Glass PanelLocation Safety InformationHearth Requirements Glass FrontAlcove Installation Intake Air Restriction Venting RequirementsHorizontal Termination Vertical TerminationHorizontal RUN Vertical Vent TerminationVenting Through a Fireplace Co-linear Vent InstallationThese installation requirements must be followed Min. / Max. Horizontal Run Horizontal Vent TerminationHorizontal Termination with Vertical Rise Wall Shield InstallationMin inches, U.S. / *12 inches 30 cm can Horizontal Termination ClearanceTools required Mobile Home InstallationConversion Kit Contents Never USE AN Open Flame to Check for GAS Leaks Gas Conversion ProcedureLeak test Gas Supply ConnectionInches water column High Altitude AdjustmentGas Pressure High Altitude Orifice Chart GF 200 DV II Only Flame Appearance Air Shutter AdjustmentDerating Procedure To adjust the air shutterRemote Control Optional Wall Thermostat or Remote ControlLog Set Installation Proper pilot flame appearance System CheckGlass and Gasket Replacement MaintenanceOnly Use Replacement Kit OperationDate of Purchase Name of InstallerOptional Blower # InstallationBlower Operation Connect power cord to the nearest outletAttach the Blower to the stove Snapstat terminal. See figs.3547a 47b 47b Parts List GF 100 DV II / GF 200 DV II Firebox Assembly47a GF 100 DV II Nordic QT GF 200 DV II Lillehammer GF 100 DV II Nordic QT Cast Iron Parts ListInstall the Lower Panel Optional Antique Brick Panel Kit InstallationInstall the Logset. Refer to pg Replace the Glass FrameControl Valve Lighting InstructionsJøtul North America Jøtul AS