Pilot Assembly

LIGHTING INSTRUCTIONS

GF 100 DV II Nordic QT GF 200 DV II Lillehammer

FOR YOUR SAFETY, READ BEFORE LIGHTING.

WARNING:

IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY

RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY, OR LOSS OF LIFE.

A. This appliance has a pilot which must be lit by hand. When lighting the pilot, follow these instructions exactly.

B.BEFORE LIGHTING, smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle to the floor.

WHAT TO DO IF YOU SMELL GAS:

Extinguish any open flame.

Open windows.

Do not light any appliance.

Do not touch any electrical switches.

Do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone.

If your gas supplier cannot be reached, call the fire department.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, do not try to repair it. Call a qualified technician. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

LIGHTING INSTRUCTIONS

1.STOP! Read the safety information above.

2.Access the lower controls.

3.Turn the stove ON/OFF switch to“OFF”, or set the thermostat to lowest setting (if used).

4.Confirm that the gas supply line shut-off valve is open.

Control

 

 

Knob

PILOT

ON

 

OFF

 

 

Control Valve

5.Push in gas control knob slightly and turn clockwise

to“OFF”.

NOTE: Knob cannot be turned from“PILOT”to“OFF” unless the knob is pushed in slightly. Do not force.

6.Wait five (5) minutes to clear out any gas. If you then smell gas,STOP! Follow“B”in the safety information above on this page. If you do not smell gas, go to the

next step.

7.Push in gas control knob slightly and turn counter-

clockwise to“PILOT”.

8.Push in control knob all the way and hold in. Immediately light the pilot by triggering the spark ignitor (push the red button repeatedly) until pilot lights. Continue to hold the control knob in for about one minute after

the pilot lights. Release knob and it should spring back. The pilot should remain lit. If it goes out, repeat Steps 5 through 8.

• If knob does not return when released,

stop and immediately call your service technician or gas supplier.

• If pilot will not stay lit after several tries, turn the control knob to OFF and call your service technician or gas supplier.

9.Turn gas control knob counterclockwise to“ON”.

10.Turn the stove ON/OFF switch to“ON”,or set thermostat (if used) to desired temperature.

TO TURN OFF GAS TO THE APPLIANCE:

1.Turn ON/OFF switch to”OFF”.The pilot will remain lit for normal service.

2.For complete shutdown, turn ON/OFF switch to“OFF”.

3.Access the lower controls.

4.Depress gas control knob slightly and turn clock-

wise

to“OFF”. Do not force.

31

Image 31
Contents Installation and Operation Instructions Welcome to Jøtul Table of Contents Input Rates Jøtul GF 100 DV II Nordic QT SpecificationsGF 100 DV II Miscellaneous Kit Contents GF 100 DV II AccessoriesGF 200 DV II Miscellaneous Kit Contents Jøtul GF 200 DV II Lillehammer SpecificationsRemove the Glass Panel Stove SetupSuggested Tools for Installation and Service Remove the Top PlateGlass Front Safety InformationLocation Hearth RequirementsAlcove Installation Vertical Termination Venting RequirementsIntake Air Restriction Horizontal TerminationHorizontal RUN Vertical Vent TerminationThese installation requirements must be followed Co-linear Vent InstallationVenting Through a Fireplace Min. / Max. Horizontal Run Horizontal Vent TerminationHorizontal Termination with Vertical Rise Wall Shield InstallationMin inches, U.S. / *12 inches 30 cm can Horizontal Termination ClearanceConversion Kit Contents Mobile Home InstallationTools required Never USE AN Open Flame to Check for GAS Leaks Gas Conversion ProcedureLeak test Gas Supply ConnectionGas Pressure High Altitude AdjustmentInches water column To adjust the air shutter Flame Appearance Air Shutter AdjustmentHigh Altitude Orifice Chart GF 200 DV II Only Derating ProcedureLog Set Installation Optional Wall Thermostat or Remote ControlRemote Control Proper pilot flame appearance System CheckOperation MaintenanceGlass and Gasket Replacement Only Use Replacement KitDate of Purchase Name of InstallerOptional Blower # InstallationSnapstat terminal. See figs.35 Connect power cord to the nearest outletBlower Operation Attach the Blower to the stove47a 47b 47a Parts List GF 100 DV II / GF 200 DV II Firebox Assembly47b GF 100 DV II Nordic QT GF 200 DV II Lillehammer GF 100 DV II Nordic QT Cast Iron Parts ListReplace the Glass Frame Optional Antique Brick Panel Kit InstallationInstall the Lower Panel Install the Logset. Refer to pgControl Valve Lighting InstructionsJøtul North America Jøtul AS