GF 100 DV II Nordic QT
GF 200 DV II Lillehammer
General Information
THIS HEATER MUST BE INSTALLED AND MAINTAINED BY A QUALIFIED SERVICE AGENCY.
The installation and repair of this appliance must be done by a qualified service person. Failure to properly install and maintain this heater could result in an unsafe or hazardous installation, which may result in a fire, explosion, property damage, personal injury or loss of life.
This appliance should be inspected before use and at least annually. More frequent cleaning may be required due to excessive lint from carpeting, bedding material, etc. It is imperative that control compart- ments, burners, and circulating air passageways of the appliance be kept clean.
THIS APPLIANCE MUST NOT BE CONNECTED TO A CHIMNEY OR FLUE SERVING ANY OTHER APPLIANCE.
The installation must conform to local codes. Your local Jøtul dealer can assist you in determining what is required in your area for a safe and legal installa- tion. Some areas require a permit to install a gas burning appliance. Always consult your local building inspector, or authority having jurisdiction, to deter- mine what regulations apply in your area.
NOTE: Your local officials have final authority in determining if a proposed installation is acceptable. Any requirement that is requested by the local authority having jurisdiction, that is not specifically addressed in THIS manual, defaults to local code. In the absence of local codes, the installation require- ments must comply with the current National codes. In the U.S., these requirements are established in the National Fuel Code, ANSI Z223.1.(NFPA 54). In Canada, the codes have been established in CAN/CGA B149 Fuel Installation Code.
Installer l’appareil selon les codes ou reglements locaux, ou, en l’absence de tels reglements, selon les Codes d’installation
DO NOT OPERATE THIS STOVE IF ANY PART HAS BEEN UNDER WATER. Call a qualified service technician to inspect the heater and to replace any part of the control system and any gas control which may have been under water.
Ne pas se servir de cet appareil s’il a ete’ plonge dans l’eau, completement ou en partie. Appeler un technicien qualifie pour inspecter l’appareil et remplacer toute partie du syste’me de controle et toute commande qui ont ete plonges dans l’eau.
Stove Setup
Inspect the stove for damage and contact your dealer immediately if any is found. Check contents of the Miscellaneous Kit against the lists on p.
1.Remove the Top Plate.
Simply lift it from the stove body.
2.GF 100 DV II ONLY : Remove the Front Plate. Slide it straight up to disengage it from the Side Plates.
3.GF 200 DV II ONLY: Open the Front Doors.
Cut the two cable ties that secure the doors closed.
4.Remove the Glass Panel.
Open the two trunk latches at the top of the firebox to disengage the Glass Panel Frame. Lift the frame up and out of its channel. Set it aside, out of the way, on a soft surface.
5.Install Optional Blower if appropriate.
6.Install Vent System / Air Restriction as appropriate.
7.Install Fuel Conversion / High Altitude Adjust- ment if necessary.
8.Plumb gas line to the stove. Leak Test.
9.Install optional Brick Panels.
10.Install Log Set and Ember Stones.
11.Replace Glass Panel. Test Burner and adjust air shutter if necessary.
12.Replace Front Panel and Top Plate.
13.Install optional Remote Control or Thermostat.
Suggested Tools for
Installation and Service
•External regulator (for Propane only)
•Piping which complies with local code
•Manual
•Sediment trap - if required by code
•Tee joint
•Pipe wrench
•Pipe sealant
•10 mm open end wrench
•1/2”, 7/16” open end wrench or deep socket
• | Phillips head screwdriver | • | Safety glasses |
• | Flat head screwdriver | • | Torx T20 screwdriver |
• | 1/4” nut driver | • | Leak test solution |
• 4 mm allen wrench | • Reciprocating Saw | ||
• | Gloves | • | Power Drill |
6