Jotul GF 100 DV II, GF 200 DV II manual Stove Setup, Suggested Tools for Installation and Service

Page 6

GF 100 DV II Nordic QT

GF 200 DV II Lillehammer

General Information

„THIS HEATER MUST BE INSTALLED AND MAINTAINED BY A QUALIFIED SERVICE AGENCY.

„The installation and repair of this appliance must be done by a qualified service person. Failure to properly install and maintain this heater could result in an unsafe or hazardous installation, which may result in a fire, explosion, property damage, personal injury or loss of life.

„This appliance should be inspected before use and at least annually. More frequent cleaning may be required due to excessive lint from carpeting, bedding material, etc. It is imperative that control compart- ments, burners, and circulating air passageways of the appliance be kept clean.

„THIS APPLIANCE MUST NOT BE CONNECTED TO A CHIMNEY OR FLUE SERVING ANY OTHER APPLIANCE.

„The installation must conform to local codes. Your local Jøtul dealer can assist you in determining what is required in your area for a safe and legal installa- tion. Some areas require a permit to install a gas burning appliance. Always consult your local building inspector, or authority having jurisdiction, to deter- mine what regulations apply in your area.

„NOTE: Your local officials have final authority in determining if a proposed installation is acceptable. Any requirement that is requested by the local authority having jurisdiction, that is not specifically addressed in THIS manual, defaults to local code. In the absence of local codes, the installation require- ments must comply with the current National codes. In the U.S., these requirements are established in the National Fuel Code, ANSI Z223.1.(NFPA 54). In Canada, the codes have been established in CAN/CGA B149 Fuel Installation Code.

„Installer l’appareil selon les codes ou reglements locaux, ou, en l’absence de tels reglements, selon les Codes d’installation CAN/CGA-B149.

„DO NOT OPERATE THIS STOVE IF ANY PART HAS BEEN UNDER WATER. Call a qualified service technician to inspect the heater and to replace any part of the control system and any gas control which may have been under water.

„Ne pas se servir de cet appareil s’il a ete’ plonge dans l’eau, completement ou en partie. Appeler un technicien qualifie pour inspecter l’appareil et remplacer toute partie du syste’me de controle et toute commande qui ont ete plonges dans l’eau.

Stove Setup

Inspect the stove for damage and contact your dealer immediately if any is found. Check contents of the Miscellaneous Kit against the lists on p. 4-5. Complete the installation steps in the following order:

1.Remove the Top Plate.

Simply lift it from the stove body.

2.GF 100 DV II ONLY : Remove the Front Plate. Slide it straight up to disengage it from the Side Plates.

3.GF 200 DV II ONLY: Open the Front Doors.

Cut the two cable ties that secure the doors closed.

4.Remove the Glass Panel.

Open the two trunk latches at the top of the firebox to disengage the Glass Panel Frame. Lift the frame up and out of its channel. Set it aside, out of the way, on a soft surface.

5.Install Optional Blower if appropriate.

6.Install Vent System / Air Restriction as appropriate.

7.Install Fuel Conversion / High Altitude Adjust- ment if necessary.

8.Plumb gas line to the stove. Leak Test.

9.Install optional Brick Panels.

10.Install Log Set and Ember Stones.

11.Replace Glass Panel. Test Burner and adjust air shutter if necessary.

12.Replace Front Panel and Top Plate.

13.Install optional Remote Control or Thermostat.

Suggested Tools for

Installation and Service

External regulator (for Propane only)

Piping which complies with local code

Manual shut-off valve (T-Handle in Massachusetts)

Sediment trap - if required by code

Tee joint

Pipe wrench

Pipe sealant

10 mm open end wrench

1/2”, 7/16” open end wrench or deep socket

Phillips head screwdriver

Safety glasses

Flat head screwdriver

Torx T20 screwdriver

1/4” nut driver

Leak test solution

• 4 mm allen wrench

• Reciprocating Saw

Gloves

Power Drill

6

Image 6
Contents Installation and Operation Instructions Welcome to Jøtul Table of Contents GF 100 DV II Accessories Jøtul GF 100 DV II Nordic QT SpecificationsGF 100 DV II Miscellaneous Kit Contents Input RatesJøtul GF 200 DV II Lillehammer Specifications GF 200 DV II Miscellaneous Kit ContentsRemove the Top Plate Stove SetupSuggested Tools for Installation and Service Remove the Glass PanelHearth Requirements Safety InformationLocation Glass FrontAlcove Installation Horizontal Termination Venting RequirementsIntake Air Restriction Vertical TerminationVertical Vent Termination Horizontal RUNCo-linear Vent Installation These installation requirements must be followedVenting Through a Fireplace Horizontal Vent Termination Min. / Max. Horizontal RunWall Shield Installation Horizontal Termination with Vertical RiseHorizontal Termination Clearance Min inches, U.S. / *12 inches 30 cm canMobile Home Installation Conversion Kit ContentsTools required Gas Conversion Procedure Never USE AN Open Flame to Check for GAS LeaksGas Supply Connection Leak testHigh Altitude Adjustment Gas PressureInches water column Derating Procedure Flame Appearance Air Shutter AdjustmentHigh Altitude Orifice Chart GF 200 DV II Only To adjust the air shutterOptional Wall Thermostat or Remote Control Log Set InstallationRemote Control System Check Proper pilot flame appearanceOnly Use Replacement Kit MaintenanceGlass and Gasket Replacement OperationName of Installer Date of PurchaseInstallation Optional Blower #Attach the Blower to the stove Connect power cord to the nearest outletBlower Operation Snapstat terminal. See figs.3547a 47b Parts List GF 100 DV II / GF 200 DV II Firebox Assembly 47a47b GF 100 DV II Nordic QT GF 200 DV II Lillehammer Cast Iron Parts List GF 100 DV II Nordic QTInstall the Logset. Refer to pg Optional Antique Brick Panel Kit InstallationInstall the Lower Panel Replace the Glass FrameLighting Instructions Control ValveJøtul AS Jøtul North America