Table 4 – Opening dimensions - In. (mm)
|
|
|
|
|
| |
FURNACE |
| PLENUM OPENING | FLOOR OPENING | |||
CASING | APPLICATION |
|
|
|
| |
WIDTH |
| A | B | C | D | |
|
|
|
|
|
| |
| Upflow Applications on Combustible or Noncombustible Floor- | |||||
| ing (KGASB subbase not required) | (322) | (549) | (338) | (565) | |
| Downflow Applications on Noncombustible Flooring (KGASB | 19 | ||||
subbase not required) | (319) | (483) | (335) | (498) | ||
Downflow applications on combustible flooring (KGASB sub- | 19 | |||||
(376) | ||||||
base required) | (284) | (483) | (341) | (600) | ||
| ||||||
| Downflow Applications on Combustible Flooring with CNPV, | 19 | 20 | |||
| CNRV, CAR, or CAP Coil Assembly or KCAKC coil box | |||||
| (319) | (483) | (338) | (508) | ||
| (KGASB subbase not required) | |||||
|
|
|
|
| ||
|
|
|
|
|
| |
| Upflow Applications on Combustible or Noncombustible Floor- | 16 | ||||
| ing (KGASB subbase not required) | (406) | (549) | (422) | (565) | |
| Downflow Applications on Noncombustible Flooring (KGASB | 19 | ||||
subbase not required) | (403) | (483) | (419) | (498) | ||
Downflow applications on combustible flooring (KGASB sub- | 19 | |||||
(445) | ||||||
base required) | (384) | (483) | (425) | (600) | ||
| ||||||
| Downflow Applications on Combustible Flooring with CNPV, | 19 | 20 | |||
| CNRV, CAR, or CAP Coil Assembly or KCAKC coil box | |||||
| (394) | (483) | (419) | (508) | ||
| (KGASB subbase not required) | |||||
|
|
|
|
| ||
|
|
|
|
|
| |
| Upflow Applications on Combustible or Noncombustible Floor- | |||||
| ing (KGASB subbase not required) | (495) | (549) | (511) | (565) | |
| Downflow Applications on Noncombustible Flooring (KGASB | 19 | 20 | |||
21 | subbase not required) | (492) | (483) | (508) | (498) | |
Downflow applications on combustible flooring (KGASB sub- | 19 | |||||
(533) | ||||||
base required) | (473) | (483) | (514) | (600) | ||
| ||||||
| Downflow Applications on Combustible Flooring with CNPV, | 19 | 19 | 20 | 20 | |
| CNRV, CAR, or CAP Coil Assembly or KCAKC coil box | |||||
| (483) | (483) | (508) | (508) | ||
| (KGASB subbase not required) | |||||
|
|
|
|
| ||
| Upflow Applications on Combustible or Noncombustible Floor- | 23 | ||||
| ing (KGASB subbase not required) | (584) | (537) | (600) | (565) | |
| Downflow Applications on Noncombustible Flooring (KGASB | 19 | ||||
subbase not required) | (581) | (483) | (597) | (498) | ||
Downflow applications on Combustible flooring (KGASB sub- | 19 | |||||
(622) | ||||||
base required) | (562) | (483) | (603) | (600) | ||
| ||||||
| Downflow Applications on Combustible Flooring with CNPV, | 19 | 20 | |||
| CNRV, CAR, or CAP Coil Assembly or KCAKC coil box | |||||
| (572) | (483) | (597) | (508) | ||
| (KGASB subbase not required) | |||||
|
|
|
|
|
58CT
UPFLOW DOWNFLOW HORIZONTAL
90û |
| 90û |
YES | YES | YES |
|
120û | YES | 120û | YES | 120û | YES |
MIN |
| MIN |
| MIN |
|
NOT | NOT | NOT |
RECOMMENDED | RECOMMENDED | RECOMMENDED |
A02329
Fig. 14 - Duct Flanges
13