Table 5 - Air Delivery - CFM (With Filter)* (Cont.)
FURNACE | SPEED |
|
| EXTERNAL STATIC PRESSURE (IN. WC) |
|
| |||||||
SIZE | INLET | 0.1 | 0.2 | 0.3 | 0.4 | 0.5 | 0.6 | 0.7 | 0.8 | 0.9 | 1.0 | ||
| |||||||||||||
Bottom | High | 2090 | 2010 | 1930 | 1835 | 1710 | 1590 | 1470 | 1335 | 1025 | 835 | ||
1790 | 1755 | 1705 | 1640 | 1550 | 1465 | 1360 | 1210 | 945 | 785 | ||||
or | |||||||||||||
048135 | 1545 | 1525 | 1500 | 1450 | 1380 | 1315 | 1215 | 1005 | 855 | 670 | |||
Side(s) | |||||||||||||
| Low | 1325 | 1320 | 1295 | 1265 | 1210 | 1150 | 995 | 865 | 745 | 540 | ||
|
| ||||||||||||
| Bottom | High | 2485 | 2400 | 2310 | 2215 | 2110 | 2000 | 1880 | 1725 | 1535 | 1355 | |
| 2195 | 2150 | 2090 | 2000 | 1920 | 1825 | 1720 | 1565 | 1405 | 1255 | |||
| Only | 1880 | 1850 | 1820 | 1780 | 1715 | 1635 | 1540 | 1415 | 1290 | 1160 | ||
|
| Low | 1640 | 1635 | 1615 | 1585 | 1530 | 1465 | 1370 | 1255 | 1150 | 1040 | |
Bottom Sides | High | 2385 | 2305 | 2195 | 2085 | 1960 | 1825 | 1670 | 1465 | ||||
2180 | 2145 | 2060 | 2010 | 1945 | 1865 | 1765 | 1660 | 1515 | 1325 | ||||
or | |||||||||||||
066135 | 1880 | 1850 | 1820 | 1780 | 1715 | 1635 | 1540 | 1415 | 1290 | 1160 | |||
1 Side & Bottom | |||||||||||||
| Low | 1640 | 1635 | 1615 | 1585 | 1530 | 1465 | 1370 | 1255 | 1150 | 1040 | ||
|
| ||||||||||||
|
| High | 2320 | 2250 | 2155 | 2055 | 1970 | 1855 | 1725 | 1600 | 1450 | 1280 | |
| 1 Side Only | 2125 | 2065 | 1995 | 1910 | 1815 | 1710 | 1610 | 1490 | 1340 | 1175 | ||
| 1845 | 1825 | 1765 | 1710 | 1650 | 1570 | 1475 | 1370 | 1240 | 1100 | |||
|
| ||||||||||||
|
| Low | 1640 | 1620 | 1580 | 1540 | 1485 | 1410 | 1330 | 1220 | 1080 | 960 | |
|
| High | 2465 | 2430 | 2375 | 2305 | 2230 | 2110 | 2000 | 1865 | 1725 | 1545 | |
| Bottom Only | 2115 | 2105 | 2075 | 2030 | 1980 | 1910 | 1830 | 1725 | 1590 | 1425 | ||
| 1800 | 1790 | 1770 | 1735 | 1695 | 1640 | 1570 | 1465 | 1345 | 1225 | |||
|
| ||||||||||||
| Low | 1570 | 1565 | 1550 | 1525 | 1495 | 1445 | 1370 | 1270 | 1175 | 1070 | ||
060155 | Both Sides Or 1 | High | 2375 | 2285 | 2200 | 2105 | 1995 | 1870 | 1730 | 1570 | |||
| Side & Bottom | 2155 | 2135 | 2095 | 2040 | 1975 | 1895 | 1790 | 1685 | 1550 | 1400 | ||
| 1 Side Only | High | 2260 | 2180 | 2085 | 1975 | 1865 | 1740 | 1605 | 1455 | |||
| 2140 | 2095 | 2040 | 1975 | 1890 | 1810 | 1705 | 1595 | 1480 | 1325 | |||
|
| ||||||||||||
*A filter is required for each return | |||||||||||||
cessory filter rack. To determine airflow performance without this filter, assume an additional 0.1 in. wc available external static pressure. |
|
| |||||||||||
|
|
|
|
|
|
|
|
|
|
58CT
NOTE: For horizontal applications, the
Downflow Furnaces
Connect
Return Air Connections
!WARNING
FIRE HAZARD
Failure to follow this warning could cause personal injury, death and/or property damage.
Never connect
Downflow Furnaces
The
Upflow and Horizontal Furnaces
The
20.) Not all horizontal furnaces are approved for side return air connections. (See Fig. 20.)
GAS PIPING
!WARNING
FIRE OR EXPLOSION HAZARD
Failure to follow this warning could result in personal injury, death, and/or property damage.
Never purge a gas line into a combustion chamber. Never test for gas leaks with an open flame. Use a commercially available soap solution made specifically for the detection of leaks to check all connections.
!WARNING
FIRE OR EXPLOSION HAZARD
Failure to follow this warning could result in personal injury, death, and/or property damage.
Use proper length of pipe to avoid stress on gas control manifold and a gas leak.
!WARNING
FIRE OR EXPLOSION HAZARD
Failure to protect gas valve inlet from water and debris could result in death, personal injury and/or property damage.
Gas valve inlet and/or inlet pipe must remain capped until gas supply line is permanently installed to protect the valve from moisture and debris. Also, install a sediment trap in the gas supply piping at the inlet to the gas valve.
17