Metreau Entry Communicators
Product Specifications - MET-ECOM-D
MET-ECOM-D Specifications
Power: | • PoE powered – no local Power Supply needed |
| • IEEE 802.3af Compliant |
|
|
Front Panel Components: | • OLED Display |
| • Integrated Color Video Camera |
| • Speaker |
| • Dual Color LED Status Bar: (Yellow/ Red) can be used to provide feedback, |
| to attract attention for action, or as general indicator. |
| • Pushbutton (Doorbell) |
| • Microphone |
|
|
OLED Display: | • |
•1.6” Diagonal Display
•180° Viewing Angle
•2000:1 Contrast Ratio
•Unit stores up to 50 .bmp images
Integrated Color Video Camera: • QVGA 320x240
•Supports Motion JPEG (MJPEG) and H.263 codecs.
•Viewing Angle: 42°
Speaker: | • 8 Ohm, 2W |
| • 80dB SPL (sound pressure level at 1 meter) |
| • Meets G.711 sound standard |
|
|
Microphone: | • |
| • Full duplex communication |
| • VoIP Telephony |
|
|
Rear Panel Components: | • Camera Viewing Angle Adjustment |
| • Ethernet Port - 10/100 Ethernet with PoE. LEDs show communication |
| activity, connection status, speeds, and mode information: |
| SPD (speed) - Green LED lights On when the connection speed is 100 |
| Mbps and turns Off when the speed is 10 Mbps. |
| L/A (link/activity) - Orange LED lights On when the Ethernet cables are |
| connected and terminated correctly, and blinks when receiving Ethernet |
| data packets. |
| • ID/Reset pushbutton: Push to set the NetLinx ID (Device only) assignment |
| for the device. Push and hold for at least 10 seconds to reset to factory |
| default settings. |
| • Status LED: Green LED provides an indication of both the system status |
| and communication status with the target Master. 1 blink every 5 seconds |
| indicates there is currently active communication between the Metreau unit |
| and a target Master. |
| • 2 |
| with each input being capable of voltage sensing. Input format is software |
| selectable with interactive power sensing for IR ports. |
| • 2 Low Voltage Relays (1A contact): |
| ports with each relay being independently controlled and supporting up to |
| 2 independent external relay devices. |
|
|
Dimensions (HWD): | • 5.364” x 3.594” x 1.559” |
| • 13.62 cm x 9.13 cm x 3.96 cm |
| Note: Refer to the Mounting Specifications section on page 16 for mounting |
| dimensions. |
|
|
Weight: | 0.90 lbs (0.408 kg) |
Metreau Entry Communicators | 5 |
|
|