AMX MET-ECOM-D manual Door Chime Setup, Door Setup

Page 79

Using the NetLinx Module

Door Chime Setup page

Door Chime Setup

Name

Description

Channel

Address

 

 

Port:Code

Port:Code

 

 

 

 

Chime 1

The name of the Chime 1 sound.

1:206

 

 

 

 

 

Chime 2

The name of the Chime 2 sound.

1:207

 

 

 

 

 

Chime 3

The name of the Chime 3 sound.

1:208

 

 

 

 

 

Chime 4

The name of the Chime 4 sound.

1:209

 

 

 

 

 

Chime 5

The name of the Chime 5 sound.

1:210

 

 

 

 

 

Chime 6

The name of the Chime 6 sound.

1:211

 

 

 

 

 

Front Door

The name of doorbell #1 as it appears in other doorbell pages.

1:212

1:221

 

 

 

 

Kitchen

The name of doorbell #2 as it appears in other doorbell pages.

1:213

1:225

 

 

 

 

Back Door

The name of doorbell #3 as it appears in other doorbell pages.

1:214

1:229

 

 

 

 

Garage

The name of doorbell #4 as it appears in other doorbell pages.

1:215

1:233

 

 

 

 

Lobby

The name of doorbell #5 as it appears in other doorbell pages.

1:216

1:237

 

 

 

 

Back

Navigates to the Door Setup page. This requires a standard

 

 

 

page flip to Door Setup.

 

 

 

 

 

 

Door Setup page

Door Setup

Name

Description

Channel

Address

 

 

Port:Code

Port:Code

 

 

 

 

Disable All Door-

Toggle the all doorbells on and off.

1:37

 

bells (YES/NO)

 

 

 

 

 

 

 

Door Chime

Navigates to the Door Chime Setup page. This requires a

 

 

Setup

standard page flip to Door Chime Setup.

 

 

 

 

 

 

Back

Navigates to the Setup page. This requires a standard page

 

 

 

flip to Setup.

 

 

 

 

 

 

Metreau Entry Communicators

73

 

 

Image 79
Contents Metreau Entry Communicators AMX Limited Warranty and Disclaimer Table of Contents Using Zero Configuration Programming Creating Popup Pages Overview Metreau Entry CommunicatorsMetreau Entry Communicators Front Components Front ComponentsMET-ECOM Specifications Product Specifications MET-ECOMRear Components Dimensions MET-ECOM-D Specifications Product Specifications MET-ECOM-DMET-ECOM-D Specifications Positioning the Camera Camera Viewing Angle AdjustmentDefault Rear Panel Connectors Wiring and ConnectionsConnections Pairing Ethernet 10/100 Base-T RJ-45 Wiring ConfigurationPoE Power Over Ethernet Ethernet Pinouts and SignalsPort Wiring Specifications Input/Output I/O Port Connections and WiringRelay Port Connections and Wiring Connecting The Device via I/OInstalling the CAT5 Suppression Ferrite Ferrite Installation RequiredSystem Diagram Intercom System DiagramWiring and Connections Metreau Entry Communicators MET-ECOM / MET-ECOM-D Installation Overview Mounting and InstallationDimensions Front View Mounting SpecificationsTop View Side ViewsTypical Installation Without Expansion Clips Typical Installation Without Expansion ClipsDevice and wall box must have an Earth ground Installing the Wall Box Without the Use of Tabs Recommended Cutout For Wall Box Wall Surface Installation Using Expansion ClipsReplacement drywall clip sets must be ordered from AMX Flat Surface Installation Points Installing Into a Flat Surface Using Mounting ScrewsRemoving the Device From the Wall Included in the Kit Using the Optional Surface Mount BoxProvides mounting specifications for the CB-MET-ECOMS Surface Mount Box SpecificationsInstalling the Metreau Entry Communicator Ferrite Installation RequiredMounting and Installation Bonjour Zero-Configuration Client Using Zero ConfigurationConnecting In a Network With a Dhcp Server This case the serial number is 218001WHP2980023 Connecting In a Network Without a Dhcp ServerInternet Properties TCP/IP Properties dialog Using Zero Configuration Metreau Entry Communicators Configuration Manager Summary of Settings Page initial view Using the Configuration ManagerAccessing the Configuration Manager Command ButtonsSummary of Device Settings Summary of Device SettingsDevice Information Checking the Firmware Version Rebooting the DeviceIP Settings NetLinx SettingsConfiguration Page Network IP Settings Tab ConfigurationSetting the DNS Address Setting the IP AddressConfiguration Page Network IP Settings Tab Setting the Icsp Connection to the NetLinx Master Configuration Page NetLinx Settings TabConfiguration Page NetLinx Settings Tab Setting a New Username and Password Configuration Page User Settings TabConfiguration Page User Settings Tab Device Utilities Device UtilitiesUtility Meta Information Images Creating Display ImagesImage File Requirements File UploadSave the file as a .BMP image FIG TPDesign4 Resource Manager Creating Dynamic ImagesCreate Dynamic Image dialog Creating a New Dynamic ImageDeleting a Display Image From the Device Uploading a Display Image To The DeviceAudio/Video Audio/Video Page Audio Settings TabSetting Device Audio Audio/Video Page Audio Settings TabVideo Codec Audio/Video Page Video Settings TabAudio/Video Page Video Settings Tab Camera/Video Stream ConfigurationAudio/Video Page Display Settings Tab Setting Device VideoAudio/Video Page Display Settings Tab Setting the Display Settings On The DeviceProgramming SENDCOMMANDsTouch Panel Intercom Commands Touch Panel Intercom CommandsMOD? STREAM-GETSTREAM-PLAY STREAM-STOPRTP, Rtcp Video and Audio Streaming Commands RTP, Rtcp Video and Audio Streaming CommandsGET Gain GET VolumeSET Volume SET AudioFace Plate LED Commands Face Plate LED CommandsCamera Commands Camera CommandsGET CAM-SAT SET CAM-CSTGET CAM-CST SET CAM-SATSET DISP-BANNER LCD CommandsLCD Commands GET CAM-FLICKGET DISP-CST SET DISP-BRTGET DISP-BRT SET DISP-CSTSystem Commands CommandsSystem Commands CommandsGET DOOR-DESC SET DOOR-DESCPreparing the Master for communication via an IP Before beginning the Upgrade processUpgrading Firmware Upgrading Firmware via an IP AddressVerifying and Upgrading the device firmware via an IP Assigning Communication Settings and TCP/IP SettingsSelect the device’s firmware file from the Files section FIG Incorporating an Intercom Panel Into Your NetLinx System Using the NetLinx ModulePanel Intercom Configuration Intercom SetupSetting Intercom Auto Answer Setting the Intercom Session TimeoutDisabling All Doorbells Door SetupAssigning a Chime To a Doorbell Door Chime SetupAllowing a Panel To Be Monitored Advanced SetupNaming a panel Allowing a Panel To MonitorAnswering an incoming Intercom call Answering an Incoming Doorbell Call Someone At The DoorName Description Channel Address PortCode Advanced SetupCreating Intercom Pages Ending a Doorbell CallDoor Setup Door Chime SetupSample Intercom Intercom DemoName Description Channel Address Level PortCode Panel Directory Room Name Name of a panel Setup SetupSomeone At The Door Someone At The DoorDoor Answer Call popup Doorbell Adjustments popupDoorbell Adjustments Popup Creating Popup PagesIntercom Answer Call Popup Intercom Answer Call popupMore Time Popup More Time popupProgramming Metreau Entry Communicators It’s Your World Take Control