AMX MET-ECOM-D manual Stream-Get, Stream-Play, Stream-Stop, Mod?

Page 58

Programming

Touch Panel Intercom Commands (Cont.)

STREAM-SET (Cont.)

Example (H.263 video stream):

 

SEND_COMMAND MET1, "’STREAM-SET

 

192.168.0.3,9000,9002,video,H263,1"

 

SEND_COMMAND TP2, "’^ICS-192.168.0.4,9002,9000,2’"

 

Sets up a h.263 video stream between Metreau Entry

 

Communicators and a touch panel.

 

Note: Do not change the Audio or Video Codec settings during a call.

 

 

STREAM-GET

Syntax:

Retrieves a description of the

"’STREAM-GET, <stream type> <stream_ID>’"

stream parameter being used by

• Stream end. This terminates an stream call/connection.

the current stream.

Variable:

 

 

• STREAM_TYPE: AUDIO, VIDEO

 

• STREAM_ID: 0 -10

 

Example:

 

SEND_COMMAND MET1, "’STREAM-GET, AUDIO, 1’"

 

Returns:

 

STREAM = 1 AUDIO 234.232.444.333 5000

 

Indicates that the audio stream has been configured to use and IP

 

address of 234.232.444.333 where it uses port 5000 for the audio

 

stream.

 

 

STREAM-PLAY

Syntax:

This command notifies the Metreau

SEND_COMMAND <DEV>,"'STREAM-PLAY <stream id>'"

Entry Communicator to start

Variable:

streaming by enabling the micro-

• <stream ID> integers are from 1-20.

phone, speaker and video source

 

and then, transmitting packets and

Example:

playing received packets.

SEND_COMMAND MET1,"STREAM-PLAY 1"

 

 

 

STREAM-STOP

Syntax:

Stops transmission and receive of

SEND_COMMAND <DEV>,"'STREAM-STOP <stream id>'"

stream. This command terminates

Variable:

the data from moving in a stream

• <stream ID> integers are from 1-20.

connection.

• If <stream ID> = "ALL" will remove all streams

 

 

Example:

 

SEND_COMMAND MET1,"’STREAM-STOP 1’"

 

Stops stream 1 from running.

 

 

^MOD?

The Metreau Entry Communicator will respond with its model name

Metreau Entry Communicator

as shown in the response below. Older hardware or newer hardware

that has intercom support disabled will not respond to this command.

model name.

The Metreau Entry Communicator will respond with one of the follow-

 

 

ing strings:

 

Syntax:

 

SEND_COMMAND <DEV>,"’^MOD?’"

 

Example:

 

SEND_COMMAND MET1,"’^MOD?’"

 

Returns:

 

^MODEL-MET-2007-A

 

 

52

Metreau Entry Communicators

Image 58
Contents Metreau Entry Communicators AMX Limited Warranty and Disclaimer Table of Contents Using Zero Configuration Programming Creating Popup Pages Metreau Entry Communicators OverviewFront Components Metreau Entry Communicators Front ComponentsMET-ECOM Specifications Product Specifications MET-ECOMRear Components Dimensions Product Specifications MET-ECOM-D MET-ECOM-D SpecificationsMET-ECOM-D Specifications Camera Viewing Angle Adjustment Positioning the CameraDefault Wiring and Connections Rear Panel ConnectorsEthernet Pinouts and Signals Ethernet 10/100 Base-T RJ-45 Wiring ConfigurationPoE Power Over Ethernet Connections PairingConnecting The Device via I/O Input/Output I/O Port Connections and WiringRelay Port Connections and Wiring Port Wiring SpecificationsFerrite Installation Required Installing the CAT5 Suppression FerriteSystem Diagram System Diagram IntercomWiring and Connections Metreau Entry Communicators MET-ECOM / MET-ECOM-D Installation Overview Mounting and InstallationDimensions Mounting Specifications Front ViewSide Views Top ViewTypical Installation Without Expansion Clips Typical Installation Without Expansion ClipsDevice and wall box must have an Earth ground Installing the Wall Box Without the Use of Tabs Wall Surface Installation Using Expansion Clips Recommended Cutout For Wall BoxReplacement drywall clip sets must be ordered from AMX Installing Into a Flat Surface Using Mounting Screws Flat Surface Installation PointsRemoving the Device From the Wall Using the Optional Surface Mount Box Included in the KitSurface Mount Box Specifications Provides mounting specifications for the CB-MET-ECOMSFerrite Installation Required Installing the Metreau Entry CommunicatorMounting and Installation Bonjour Zero-Configuration Client Using Zero ConfigurationConnecting In a Network With a Dhcp Server Connecting In a Network Without a Dhcp Server This case the serial number is 218001WHP2980023Internet Properties TCP/IP Properties dialog Using Zero Configuration Metreau Entry Communicators Using the Configuration Manager Configuration Manager Summary of Settings Page initial viewCommand Buttons Accessing the Configuration ManagerSummary of Device Settings Summary of Device SettingsDevice Information NetLinx Settings Rebooting the DeviceIP Settings Checking the Firmware VersionConfiguration Configuration Page Network IP Settings TabSetting the DNS Address Setting the IP AddressConfiguration Page Network IP Settings Tab Setting the Icsp Connection to the NetLinx Master Configuration Page NetLinx Settings TabConfiguration Page NetLinx Settings Tab Setting a New Username and Password Configuration Page User Settings TabConfiguration Page User Settings Tab Device Utilities Device UtilitiesUtility Meta Information File Upload Creating Display ImagesImage File Requirements ImagesSave the file as a .BMP image FIG Creating Dynamic Images TPDesign4 Resource ManagerCreating a New Dynamic Image Create Dynamic Image dialogUploading a Display Image To The Device Deleting a Display Image From the DeviceAudio/Video Page Audio Settings Tab Audio/Video Page Audio Settings TabSetting Device Audio Audio/VideoCamera/Video Stream Configuration Audio/Video Page Video Settings TabAudio/Video Page Video Settings Tab Video CodecSetting Device Video Audio/Video Page Display Settings TabSetting the Display Settings On The Device Audio/Video Page Display Settings TabTouch Panel Intercom Commands SENDCOMMANDsTouch Panel Intercom Commands ProgrammingSTREAM-STOP STREAM-GETSTREAM-PLAY MOD?RTP, Rtcp Video and Audio Streaming Commands RTP, Rtcp Video and Audio Streaming CommandsSET Audio GET VolumeSET Volume GET GainFace Plate LED Commands Face Plate LED CommandsCamera Commands Camera CommandsSET CAM-SAT SET CAM-CSTGET CAM-CST GET CAM-SATGET CAM-FLICK LCD CommandsLCD Commands SET DISP-BANNERSET DISP-CST SET DISP-BRTGET DISP-BRT GET DISP-CSTCommands CommandsSystem Commands System CommandsSET DOOR-DESC GET DOOR-DESCUpgrading Firmware via an IP Address Before beginning the Upgrade processUpgrading Firmware Preparing the Master for communication via an IPAssigning Communication Settings and TCP/IP Settings Verifying and Upgrading the device firmware via an IPSelect the device’s firmware file from the Files section FIG Intercom Setup Using the NetLinx ModulePanel Intercom Configuration Incorporating an Intercom Panel Into Your NetLinx SystemSetting the Intercom Session Timeout Setting Intercom Auto AnswerDoor Setup Disabling All DoorbellsDoor Chime Setup Assigning a Chime To a DoorbellAdvanced Setup Allowing a Panel To Be MonitoredNaming a panel Allowing a Panel To MonitorAnswering an incoming Intercom call Someone At The Door Answering an Incoming Doorbell CallEnding a Doorbell Call Advanced SetupCreating Intercom Pages Name Description Channel Address PortCodeDoor Chime Setup Door SetupSample Intercom Intercom DemoName Description Channel Address Level PortCode Panel Directory Room Name Name of a panel Setup SetupSomeone At The Door Someone At The DoorCreating Popup Pages Doorbell Adjustments popupDoorbell Adjustments Popup Door Answer Call popupIntercom Answer Call popup Intercom Answer Call PopupMore Time popup More Time PopupProgramming Metreau Entry Communicators It’s Your World Take Control