AMX MET-ECOM-D manual RTP, Rtcp Video and Audio Streaming Commands

Page 59

Programming

Touch Panel Intercom Commands (Cont.)

^VER?

Metreau Entry Communicator version number.

The Metreau Entry Communicator will respond with its version num- ber as shown in the response below. The Metreau Entry Communica- tor will respond with one of the following strings:

Syntax:

SEND_COMMAND <DEV>,"’^VER?’"

Example:

SEND_COMMAND MET1,"’^VER?’"

Returns:

VERSION xx.xxx.xxx

RTP, RTCP Video and Audio Streaming Commands

Metreau Entry Communicators support the following RTP, RTCP Video and Audio Streaming SEND_COMMANDs on port 1.

RTP, RTCP Video and Audio Streaming Commands

GET VIDEO

Syntax:

Retrieves the configuration of the

SEND_COMMAND <DEV>,"'GET VIDEO'"

video system.

Example:

Information returned includes

SEND_COMMAND MET1,"'GET VIDEO'"

codec, resolution, and bit rate.

Returns:

Codec can be either H-263 or

VIDEO = MJPEG

MJPEG.

 

 

SET VIDEO

Syntax:

Sets the configuration of the video

SEND_COMMAND <DEV>,"'SET VIDEO <Codec>'"

system.

Variable:

Configuration includes codec,

• Codec = OFF, H263 or MJPEG

resolution, and bit rate.

Example:

Note: See the STREAM-SET

SEND_COMMAND MET1,"'SET VIDEO MJPEG'"

command for details on setting up

a H.263 video stream.

Sets the video configuration to a very high quality stream.

 

Note: Do not change the Audio or Video Codec settings during a call.

 

 

GET AUDIO

Syntax:

Gets the current configuration of

SEND_COMMAND <DEV>,"'GET AUDIO'"

the video system.

Example:

Configuration includes codec.

SEND_COMMAND MET1,"'GET AUDIO'"

 

 

Returns:

 

AUDIO = G.711ULAW

 

 

Metreau Entry Communicators

53

 

 

Image 59
Contents Metreau Entry Communicators AMX Limited Warranty and Disclaimer Table of Contents Using Zero Configuration Programming Creating Popup Pages Overview Metreau Entry CommunicatorsMetreau Entry Communicators Front Components Front ComponentsRear Components Product Specifications MET-ECOMMET-ECOM Specifications Dimensions MET-ECOM-D Specifications Product Specifications MET-ECOM-DMET-ECOM-D Specifications Positioning the Camera Camera Viewing Angle AdjustmentDefault Rear Panel Connectors Wiring and ConnectionsConnections Pairing Ethernet 10/100 Base-T RJ-45 Wiring ConfigurationPoE Power Over Ethernet Ethernet Pinouts and SignalsPort Wiring Specifications Input/Output I/O Port Connections and WiringRelay Port Connections and Wiring Connecting The Device via I/OInstalling the CAT5 Suppression Ferrite Ferrite Installation RequiredSystem Diagram Intercom System DiagramWiring and Connections Metreau Entry Communicators Dimensions Mounting and InstallationMET-ECOM / MET-ECOM-D Installation Overview Front View Mounting SpecificationsTop View Side ViewsTypical Installation Without Expansion Clips Typical Installation Without Expansion ClipsDevice and wall box must have an Earth ground Installing the Wall Box Without the Use of Tabs Recommended Cutout For Wall Box Wall Surface Installation Using Expansion ClipsReplacement drywall clip sets must be ordered from AMX Flat Surface Installation Points Installing Into a Flat Surface Using Mounting ScrewsRemoving the Device From the Wall Included in the Kit Using the Optional Surface Mount BoxProvides mounting specifications for the CB-MET-ECOMS Surface Mount Box SpecificationsInstalling the Metreau Entry Communicator Ferrite Installation RequiredMounting and Installation Connecting In a Network With a Dhcp Server Using Zero ConfigurationBonjour Zero-Configuration Client This case the serial number is 218001WHP2980023 Connecting In a Network Without a Dhcp ServerInternet Properties TCP/IP Properties dialog Using Zero Configuration Metreau Entry Communicators Configuration Manager Summary of Settings Page initial view Using the Configuration ManagerAccessing the Configuration Manager Command ButtonsDevice Information Summary of Device SettingsSummary of Device Settings Checking the Firmware Version Rebooting the DeviceIP Settings NetLinx SettingsConfiguration Page Network IP Settings Tab ConfigurationConfiguration Page Network IP Settings Tab Setting the IP AddressSetting the DNS Address Configuration Page NetLinx Settings Tab Configuration Page NetLinx Settings TabSetting the Icsp Connection to the NetLinx Master Configuration Page User Settings Tab Configuration Page User Settings TabSetting a New Username and Password Utility Meta Information Device UtilitiesDevice Utilities Images Creating Display ImagesImage File Requirements File UploadSave the file as a .BMP image FIG TPDesign4 Resource Manager Creating Dynamic ImagesCreate Dynamic Image dialog Creating a New Dynamic ImageDeleting a Display Image From the Device Uploading a Display Image To The DeviceAudio/Video Audio/Video Page Audio Settings TabSetting Device Audio Audio/Video Page Audio Settings TabVideo Codec Audio/Video Page Video Settings TabAudio/Video Page Video Settings Tab Camera/Video Stream ConfigurationAudio/Video Page Display Settings Tab Setting Device VideoAudio/Video Page Display Settings Tab Setting the Display Settings On The DeviceProgramming SENDCOMMANDsTouch Panel Intercom Commands Touch Panel Intercom CommandsMOD? STREAM-GETSTREAM-PLAY STREAM-STOPRTP, Rtcp Video and Audio Streaming Commands RTP, Rtcp Video and Audio Streaming CommandsGET Gain GET VolumeSET Volume SET AudioFace Plate LED Commands Face Plate LED CommandsCamera Commands Camera CommandsGET CAM-SAT SET CAM-CSTGET CAM-CST SET CAM-SATSET DISP-BANNER LCD CommandsLCD Commands GET CAM-FLICKGET DISP-CST SET DISP-BRTGET DISP-BRT SET DISP-CSTSystem Commands CommandsSystem Commands CommandsGET DOOR-DESC SET DOOR-DESCPreparing the Master for communication via an IP Before beginning the Upgrade processUpgrading Firmware Upgrading Firmware via an IP AddressVerifying and Upgrading the device firmware via an IP Assigning Communication Settings and TCP/IP SettingsSelect the device’s firmware file from the Files section FIG Incorporating an Intercom Panel Into Your NetLinx System Using the NetLinx ModulePanel Intercom Configuration Intercom SetupSetting Intercom Auto Answer Setting the Intercom Session TimeoutDisabling All Doorbells Door SetupAssigning a Chime To a Doorbell Door Chime SetupAllowing a Panel To Be Monitored Advanced SetupAnswering an incoming Intercom call Allowing a Panel To MonitorNaming a panel Answering an Incoming Doorbell Call Someone At The DoorName Description Channel Address PortCode Advanced SetupCreating Intercom Pages Ending a Doorbell CallDoor Setup Door Chime SetupName Description Channel Address Level PortCode Intercom DemoSample Intercom Panel Directory Room Name Name of a panel Setup SetupSomeone At The Door Someone At The DoorDoor Answer Call popup Doorbell Adjustments popupDoorbell Adjustments Popup Creating Popup PagesIntercom Answer Call Popup Intercom Answer Call popupMore Time Popup More Time popupProgramming Metreau Entry Communicators It’s Your World Take Control