AMX MET-ECOM-D Wall Surface Installation Using Expansion Clips, Recommended Cutout For Wall Box

Page 27

Mounting and Installation

Wall Surface Installation (Using Expansion Clips)

Expansion clips are mounted through the 2 holes located along the rim of the wall box (see FIG. 18). As the screw is tightened, the clip bends toward the insertion hole and into the wall. This bending creates a "grip" on the wall by either pressing onto the wall or by securing the drywall between the housing and the drywall clip. The most important thing to remember when mounting the wall box is that the outer trim must be installed flush against the mounting surface.

FIG. 18 provides recommended cutout dimensions for the wall box. It is recommended that you cutout the surface slightly smaller than what is outlined in the installation drawings so that you can make any necessary cutout adjustments.

FIG. 18 Recommended Cutout For Wall Box

Be sure to install the Cat5 Suppression Ferrite (provided) before mounting the Metreau Entry Communicator unit into the wall box. Refer to the Ferrite Installation (Required) section on page 12 for details.

1.If assembled, remove the Metreau Entry Communicator from the wall box.

2.Cut out the surface for the Wall Box using the dimensions shown in FIG. 18.

3.Run the Ethernet cable and an Earth ground wire into the wall box through the provided breakaway access points on the wall box. Leave enough slack in the wiring to accommodate any re-positioning of the unit.

Metreau Entry Communicators

21

 

 

Image 27
Contents Metreau Entry Communicators AMX Limited Warranty and Disclaimer Table of Contents Using Zero Configuration Programming Creating Popup Pages Overview Metreau Entry CommunicatorsMetreau Entry Communicators Front Components Front ComponentsProduct Specifications MET-ECOM MET-ECOM SpecificationsRear Components Dimensions MET-ECOM-D Specifications Product Specifications MET-ECOM-DMET-ECOM-D Specifications Positioning the Camera Camera Viewing Angle AdjustmentDefault Rear Panel Connectors Wiring and ConnectionsConnections Pairing Ethernet 10/100 Base-T RJ-45 Wiring ConfigurationPoE Power Over Ethernet Ethernet Pinouts and SignalsPort Wiring Specifications Input/Output I/O Port Connections and WiringRelay Port Connections and Wiring Connecting The Device via I/OInstalling the CAT5 Suppression Ferrite Ferrite Installation RequiredSystem Diagram Intercom System DiagramWiring and Connections Metreau Entry Communicators Mounting and Installation MET-ECOM / MET-ECOM-D Installation OverviewDimensions Front View Mounting SpecificationsTop View Side ViewsTypical Installation Without Expansion Clips Typical Installation Without Expansion ClipsDevice and wall box must have an Earth ground Installing the Wall Box Without the Use of Tabs Recommended Cutout For Wall Box Wall Surface Installation Using Expansion ClipsReplacement drywall clip sets must be ordered from AMX Flat Surface Installation Points Installing Into a Flat Surface Using Mounting ScrewsRemoving the Device From the Wall Included in the Kit Using the Optional Surface Mount BoxProvides mounting specifications for the CB-MET-ECOMS Surface Mount Box SpecificationsInstalling the Metreau Entry Communicator Ferrite Installation RequiredMounting and Installation Using Zero Configuration Bonjour Zero-Configuration ClientConnecting In a Network With a Dhcp Server This case the serial number is 218001WHP2980023 Connecting In a Network Without a Dhcp ServerInternet Properties TCP/IP Properties dialog Using Zero Configuration Metreau Entry Communicators Configuration Manager Summary of Settings Page initial view Using the Configuration ManagerAccessing the Configuration Manager Command ButtonsSummary of Device Settings Summary of Device SettingsDevice Information Checking the Firmware Version Rebooting the DeviceIP Settings NetLinx SettingsConfiguration Page Network IP Settings Tab ConfigurationSetting the IP Address Setting the DNS AddressConfiguration Page Network IP Settings Tab Configuration Page NetLinx Settings Tab Setting the Icsp Connection to the NetLinx MasterConfiguration Page NetLinx Settings Tab Configuration Page User Settings Tab Setting a New Username and PasswordConfiguration Page User Settings Tab Device Utilities Device UtilitiesUtility Meta Information Images Creating Display ImagesImage File Requirements File UploadSave the file as a .BMP image FIG TPDesign4 Resource Manager Creating Dynamic ImagesCreate Dynamic Image dialog Creating a New Dynamic ImageDeleting a Display Image From the Device Uploading a Display Image To The DeviceAudio/Video Audio/Video Page Audio Settings TabSetting Device Audio Audio/Video Page Audio Settings TabVideo Codec Audio/Video Page Video Settings TabAudio/Video Page Video Settings Tab Camera/Video Stream ConfigurationAudio/Video Page Display Settings Tab Setting Device VideoAudio/Video Page Display Settings Tab Setting the Display Settings On The DeviceProgramming SENDCOMMANDsTouch Panel Intercom Commands Touch Panel Intercom CommandsMOD? STREAM-GETSTREAM-PLAY STREAM-STOPRTP, Rtcp Video and Audio Streaming Commands RTP, Rtcp Video and Audio Streaming CommandsGET Gain GET VolumeSET Volume SET AudioFace Plate LED Commands Face Plate LED CommandsCamera Commands Camera CommandsGET CAM-SAT SET CAM-CSTGET CAM-CST SET CAM-SATSET DISP-BANNER LCD CommandsLCD Commands GET CAM-FLICKGET DISP-CST SET DISP-BRTGET DISP-BRT SET DISP-CSTSystem Commands CommandsSystem Commands CommandsGET DOOR-DESC SET DOOR-DESCPreparing the Master for communication via an IP Before beginning the Upgrade processUpgrading Firmware Upgrading Firmware via an IP AddressVerifying and Upgrading the device firmware via an IP Assigning Communication Settings and TCP/IP SettingsSelect the device’s firmware file from the Files section FIG Incorporating an Intercom Panel Into Your NetLinx System Using the NetLinx ModulePanel Intercom Configuration Intercom SetupSetting Intercom Auto Answer Setting the Intercom Session TimeoutDisabling All Doorbells Door SetupAssigning a Chime To a Doorbell Door Chime SetupAllowing a Panel To Be Monitored Advanced SetupAllowing a Panel To Monitor Naming a panelAnswering an incoming Intercom call Answering an Incoming Doorbell Call Someone At The DoorName Description Channel Address PortCode Advanced SetupCreating Intercom Pages Ending a Doorbell CallDoor Setup Door Chime SetupIntercom Demo Sample IntercomName Description Channel Address Level PortCode Panel Directory Room Name Name of a panel Setup SetupSomeone At The Door Someone At The DoorDoor Answer Call popup Doorbell Adjustments popupDoorbell Adjustments Popup Creating Popup PagesIntercom Answer Call Popup Intercom Answer Call popupMore Time Popup More Time popupProgramming Metreau Entry Communicators It’s Your World Take Control