AMX MET-ECOM-D manual Summary of Device Settings, Device Information

Page 41

Using the Configuration Manager

Summary of <Device> Settings Page

The Summary of Device Settings page (FIG. 31) is the initial view when the Configuration Manager is accessed.

FIG. 31 Summary of Device Settings Page

Naturally, this page can be accessed at any time via the Summary command button at the top of the web console.

Summary of Device Settings Page

Device Information

Device Type

The name of the connected device.

 

 

Firmware

The version of the firmware running on the device.

 

 

Serial #

The serial number of the device.

 

 

Location

The physical location of this device (as entered on the Device Utilities Page (Utility Meta

 

Information). See the Device Utilities Page section on page 41.

 

 

Description

A comment further describing this device (as entered on the Device Utilities Page (Utility

 

Meta Information). See the Device Utilities Page section on page 41.

 

 

Metreau Entry Communicators

35

 

 

Image 41
Contents Metreau Entry Communicators AMX Limited Warranty and Disclaimer Table of Contents Using Zero Configuration Programming Creating Popup Pages Overview Metreau Entry CommunicatorsMetreau Entry Communicators Front Components Front ComponentsRear Components Product Specifications MET-ECOMMET-ECOM Specifications Dimensions MET-ECOM-D Specifications Product Specifications MET-ECOM-DMET-ECOM-D Specifications Positioning the Camera Camera Viewing Angle AdjustmentDefault Rear Panel Connectors Wiring and ConnectionsPoE Power Over Ethernet Ethernet 10/100 Base-T RJ-45 Wiring ConfigurationEthernet Pinouts and Signals Connections PairingRelay Port Connections and Wiring Input/Output I/O Port Connections and WiringConnecting The Device via I/O Port Wiring SpecificationsInstalling the CAT5 Suppression Ferrite Ferrite Installation RequiredSystem Diagram Intercom System DiagramWiring and Connections Metreau Entry Communicators Dimensions Mounting and InstallationMET-ECOM / MET-ECOM-D Installation Overview Front View Mounting SpecificationsTop View Side ViewsTypical Installation Without Expansion Clips Typical Installation Without Expansion ClipsDevice and wall box must have an Earth ground Installing the Wall Box Without the Use of Tabs Recommended Cutout For Wall Box Wall Surface Installation Using Expansion ClipsReplacement drywall clip sets must be ordered from AMX Flat Surface Installation Points Installing Into a Flat Surface Using Mounting ScrewsRemoving the Device From the Wall Included in the Kit Using the Optional Surface Mount BoxProvides mounting specifications for the CB-MET-ECOMS Surface Mount Box SpecificationsInstalling the Metreau Entry Communicator Ferrite Installation RequiredMounting and Installation Connecting In a Network With a Dhcp Server Using Zero ConfigurationBonjour Zero-Configuration Client This case the serial number is 218001WHP2980023 Connecting In a Network Without a Dhcp ServerInternet Properties TCP/IP Properties dialog Using Zero Configuration Metreau Entry Communicators Configuration Manager Summary of Settings Page initial view Using the Configuration ManagerAccessing the Configuration Manager Command ButtonsDevice Information Summary of Device SettingsSummary of Device Settings IP Settings Rebooting the DeviceNetLinx Settings Checking the Firmware VersionConfiguration Page Network IP Settings Tab ConfigurationConfiguration Page Network IP Settings Tab Setting the IP AddressSetting the DNS Address Configuration Page NetLinx Settings Tab Configuration Page NetLinx Settings TabSetting the Icsp Connection to the NetLinx Master Configuration Page User Settings Tab Configuration Page User Settings TabSetting a New Username and Password Utility Meta Information Device UtilitiesDevice Utilities Image File Requirements Creating Display ImagesFile Upload ImagesSave the file as a .BMP image FIG TPDesign4 Resource Manager Creating Dynamic ImagesCreate Dynamic Image dialog Creating a New Dynamic ImageDeleting a Display Image From the Device Uploading a Display Image To The DeviceSetting Device Audio Audio/Video Page Audio Settings TabAudio/Video Page Audio Settings Tab Audio/VideoAudio/Video Page Video Settings Tab Audio/Video Page Video Settings TabCamera/Video Stream Configuration Video CodecAudio/Video Page Display Settings Tab Setting Device VideoAudio/Video Page Display Settings Tab Setting the Display Settings On The DeviceTouch Panel Intercom Commands SENDCOMMANDsTouch Panel Intercom Commands ProgrammingSTREAM-PLAY STREAM-GETSTREAM-STOP MOD?RTP, Rtcp Video and Audio Streaming Commands RTP, Rtcp Video and Audio Streaming CommandsSET Volume GET VolumeSET Audio GET GainFace Plate LED Commands Face Plate LED CommandsCamera Commands Camera CommandsGET CAM-CST SET CAM-CSTSET CAM-SAT GET CAM-SATLCD Commands LCD CommandsGET CAM-FLICK SET DISP-BANNERGET DISP-BRT SET DISP-BRTSET DISP-CST GET DISP-CSTSystem Commands CommandsCommands System CommandsGET DOOR-DESC SET DOOR-DESCUpgrading Firmware Before beginning the Upgrade processUpgrading Firmware via an IP Address Preparing the Master for communication via an IPVerifying and Upgrading the device firmware via an IP Assigning Communication Settings and TCP/IP SettingsSelect the device’s firmware file from the Files section FIG Panel Intercom Configuration Using the NetLinx ModuleIntercom Setup Incorporating an Intercom Panel Into Your NetLinx SystemSetting Intercom Auto Answer Setting the Intercom Session TimeoutDisabling All Doorbells Door SetupAssigning a Chime To a Doorbell Door Chime SetupAllowing a Panel To Be Monitored Advanced SetupAnswering an incoming Intercom call Allowing a Panel To MonitorNaming a panel Answering an Incoming Doorbell Call Someone At The DoorCreating Intercom Pages Advanced SetupEnding a Doorbell Call Name Description Channel Address PortCodeDoor Setup Door Chime SetupName Description Channel Address Level PortCode Intercom DemoSample Intercom Panel Directory Room Name Name of a panel Setup SetupSomeone At The Door Someone At The DoorDoorbell Adjustments Popup Doorbell Adjustments popupCreating Popup Pages Door Answer Call popupIntercom Answer Call Popup Intercom Answer Call popupMore Time Popup More Time popupProgramming Metreau Entry Communicators It’s Your World Take Control