AMX MET-ECOM-D Intercom Demo, Sample Intercom, Name Description Channel Address Level PortCode

Page 80

Using the NetLinx Module

Intercom Demo page

The module for duplex intercom capable panels includes user pages. While you can create your own intercom directory page (see the Creating Intercom Pages section on page 72), it is possible to use the panel with the page shown in FIG. 56.

1

 

 

 

 

 

 

30

 

2

 

 

 

 

 

 

 

8

13

18

23

31

 

 

 

 

3

 

 

 

 

 

 

 

9

14

19

24

 

 

4

10

15

20

25

 

 

5

11

16

21

26

 

 

 

 

 

 

 

 

 

12

17

22

27

32

 

6

 

 

 

 

 

 

7

 

28

 

 

33

 

 

 

 

 

 

 

 

29

 

 

 

FIG. 56 Sample Intercom Page

 

 

 

 

 

 

 

 

 

 

 

 

Sample Intercom Page

 

 

 

 

 

 

 

 

 

 

 

No.

Name

Description

Channel

Address

Level

 

 

 

Port:Code

Port:Code

Port:Code

 

 

 

 

 

 

 

1

Room Name

The name of the panel as it

 

 

0:265

 

 

 

appears in other intercom

 

 

 

 

 

 

directories. See Naming a

 

 

 

 

 

 

panel section on page 70.

 

 

 

 

 

 

 

 

 

 

 

2

Page All

Pages all connected intercom

1:6

 

 

 

 

 

panels.

 

 

 

 

 

 

 

 

 

 

 

3

Place Call

Initiates an intercom call to a

1:7

 

 

 

 

 

panel.

 

 

 

 

 

 

 

 

 

 

 

4

End

Ends an intercom call to a

1:8

 

 

 

 

 

panel.

 

 

 

 

 

 

 

 

 

 

 

5

Call Privacy Off

Toggles the privacy option of

1:9

 

 

 

 

 

the intercom. When enabled,

 

 

 

 

 

 

other panels cannot contact the

 

 

 

 

 

 

panel.

 

 

 

 

 

 

 

 

 

 

 

6

Door Privacy Off

Toggles the privacy option of

1:36

 

 

 

 

 

the doorbell. When enabled,

 

 

 

 

 

 

doorbells in the system cannot

 

 

 

 

 

 

contact the panel.

 

 

 

 

 

 

 

 

 

 

 

7

Monitor

Enables the panel to monitor

1:19

 

 

 

 

 

another room’s intercom panel.

 

 

 

 

 

 

 

 

 

 

 

8

Panel Directory Room Name

The name of a panel in the

1:1

 

1:1

 

 

 

intercom directory. You can call

 

 

 

 

 

 

the panel, enact privacy

 

 

 

 

 

 

against the panel and monitor

 

 

 

 

 

 

the panel.

 

 

 

 

 

 

 

 

 

 

 

74

Metreau Entry Communicators

Image 80
Contents Metreau Entry Communicators AMX Limited Warranty and Disclaimer Table of Contents Using Zero Configuration Programming Creating Popup Pages Metreau Entry Communicators OverviewFront Components Metreau Entry Communicators Front ComponentsRear Components Product Specifications MET-ECOMMET-ECOM Specifications Dimensions Product Specifications MET-ECOM-D MET-ECOM-D SpecificationsMET-ECOM-D Specifications Camera Viewing Angle Adjustment Positioning the CameraDefault Wiring and Connections Rear Panel ConnectorsEthernet 10/100 Base-T RJ-45 Wiring Configuration PoE Power Over EthernetEthernet Pinouts and Signals Connections PairingInput/Output I/O Port Connections and Wiring Relay Port Connections and WiringConnecting The Device via I/O Port Wiring SpecificationsFerrite Installation Required Installing the CAT5 Suppression FerriteSystem Diagram System Diagram IntercomWiring and Connections Metreau Entry Communicators Dimensions Mounting and InstallationMET-ECOM / MET-ECOM-D Installation Overview Mounting Specifications Front ViewSide Views Top ViewTypical Installation Without Expansion Clips Typical Installation Without Expansion ClipsDevice and wall box must have an Earth ground Installing the Wall Box Without the Use of Tabs Wall Surface Installation Using Expansion Clips Recommended Cutout For Wall BoxReplacement drywall clip sets must be ordered from AMX Installing Into a Flat Surface Using Mounting Screws Flat Surface Installation PointsRemoving the Device From the Wall Using the Optional Surface Mount Box Included in the KitSurface Mount Box Specifications Provides mounting specifications for the CB-MET-ECOMSFerrite Installation Required Installing the Metreau Entry CommunicatorMounting and Installation Connecting In a Network With a Dhcp Server Using Zero ConfigurationBonjour Zero-Configuration Client Connecting In a Network Without a Dhcp Server This case the serial number is 218001WHP2980023Internet Properties TCP/IP Properties dialog Using Zero Configuration Metreau Entry Communicators Using the Configuration Manager Configuration Manager Summary of Settings Page initial viewCommand Buttons Accessing the Configuration ManagerDevice Information Summary of Device SettingsSummary of Device Settings Rebooting the Device IP SettingsNetLinx Settings Checking the Firmware VersionConfiguration Configuration Page Network IP Settings TabConfiguration Page Network IP Settings Tab Setting the IP AddressSetting the DNS Address Configuration Page NetLinx Settings Tab Configuration Page NetLinx Settings TabSetting the Icsp Connection to the NetLinx Master Configuration Page User Settings Tab Configuration Page User Settings TabSetting a New Username and Password Utility Meta Information Device UtilitiesDevice Utilities Creating Display Images Image File RequirementsFile Upload ImagesSave the file as a .BMP image FIG Creating Dynamic Images TPDesign4 Resource ManagerCreating a New Dynamic Image Create Dynamic Image dialogUploading a Display Image To The Device Deleting a Display Image From the DeviceAudio/Video Page Audio Settings Tab Setting Device AudioAudio/Video Page Audio Settings Tab Audio/VideoAudio/Video Page Video Settings Tab Audio/Video Page Video Settings TabCamera/Video Stream Configuration Video CodecSetting Device Video Audio/Video Page Display Settings TabSetting the Display Settings On The Device Audio/Video Page Display Settings TabSENDCOMMANDs Touch Panel Intercom CommandsTouch Panel Intercom Commands ProgrammingSTREAM-GET STREAM-PLAYSTREAM-STOP MOD?RTP, Rtcp Video and Audio Streaming Commands RTP, Rtcp Video and Audio Streaming CommandsGET Volume SET VolumeSET Audio GET GainFace Plate LED Commands Face Plate LED CommandsCamera Commands Camera CommandsSET CAM-CST GET CAM-CSTSET CAM-SAT GET CAM-SATLCD Commands LCD CommandsGET CAM-FLICK SET DISP-BANNERSET DISP-BRT GET DISP-BRTSET DISP-CST GET DISP-CSTCommands System CommandsCommands System CommandsSET DOOR-DESC GET DOOR-DESCBefore beginning the Upgrade process Upgrading FirmwareUpgrading Firmware via an IP Address Preparing the Master for communication via an IPAssigning Communication Settings and TCP/IP Settings Verifying and Upgrading the device firmware via an IPSelect the device’s firmware file from the Files section FIG Using the NetLinx Module Panel Intercom ConfigurationIntercom Setup Incorporating an Intercom Panel Into Your NetLinx SystemSetting the Intercom Session Timeout Setting Intercom Auto AnswerDoor Setup Disabling All DoorbellsDoor Chime Setup Assigning a Chime To a DoorbellAdvanced Setup Allowing a Panel To Be MonitoredAnswering an incoming Intercom call Allowing a Panel To MonitorNaming a panel Someone At The Door Answering an Incoming Doorbell CallAdvanced Setup Creating Intercom PagesEnding a Doorbell Call Name Description Channel Address PortCodeDoor Chime Setup Door SetupName Description Channel Address Level PortCode Intercom DemoSample Intercom Panel Directory Room Name Name of a panel Setup SetupSomeone At The Door Someone At The DoorDoorbell Adjustments popup Doorbell Adjustments PopupCreating Popup Pages Door Answer Call popupIntercom Answer Call popup Intercom Answer Call PopupMore Time popup More Time PopupProgramming Metreau Entry Communicators It’s Your World Take Control