AMX MET-ECOM-D manual Programming, SENDCOMMANDs, Touch Panel Intercom Commands, Stream-Set

Page 57

Programming

Programming

Overview

There are a select number of SEND_COMMANDs recognized by the Metreau Entry Communicators.

SEND_COMMANDs

Below is a list of SEND_COMMANDs supported by the Metreau Entry Communicators from NetLinx masters.

To use these commands, establish a Telnet session from the PC to the NetLinx master. Additionally, you could use NetLinx Studio 2.4 or the master’s web page to send the commands.

All text is based on a Unicode index.

Touch Panel Intercom Commands

Some (not all) G4 Touch Panels feature hardware to support intercom functionality.

Only Touch Panels that support intercom may be able use intercom with the Metreau

Entry Communicators.

These commands are used to setup connections between panels that are Intercom-enabled. The "^MOD" model name command (see page 52) is used to query a panel to determine if it has intercom capability.

Touch Panel Intercom Commands

STREAM-SET

Sets the parameters for a audio or H.263 video stream.

The communication parameters must include: IP address, port used, stream type, mode and stream ID.

See the SET VIDEO command for details on specifying the H.23 codec.

Note: It is not necessary to set up a video stream for motion JPEG (MJPEG) video.

Syntax:

SEND_COMMAND <DEV>,"'STREAM-SET <dest addr>, <dest port>, <source port> <stream type>, <mode>, <stream id>'"

Variables:

<stream ID> integers are from 1-20.

<mode> Starts a call to the specified IP address and ports, where initial mode is either TALK OR LISTEN. Please note, however, that no data packets will actually flow until the intercom modify command below is received.

Example (audio stream):

SEND_COMMAND MET1, "’STREAM-SET 192.168.0.3,9000,9002,audio,TALK,1’"

SEND_COMMAND TP2, "’^ICS-192.168.0.4,9002,9000,2’"

Sets up a hands-free unicast call between Metreau Entry Communicators and a touch panel.

Metreau Entry Communicators

51

 

 

Image 57
Contents Metreau Entry Communicators AMX Limited Warranty and Disclaimer Table of Contents Using Zero Configuration Programming Creating Popup Pages Overview Metreau Entry CommunicatorsMetreau Entry Communicators Front Components Front ComponentsProduct Specifications MET-ECOM MET-ECOM SpecificationsRear Components Dimensions MET-ECOM-D Specifications Product Specifications MET-ECOM-DMET-ECOM-D Specifications Positioning the Camera Camera Viewing Angle AdjustmentDefault Rear Panel Connectors Wiring and ConnectionsPoE Power Over Ethernet Ethernet 10/100 Base-T RJ-45 Wiring ConfigurationEthernet Pinouts and Signals Connections PairingRelay Port Connections and Wiring Input/Output I/O Port Connections and WiringConnecting The Device via I/O Port Wiring SpecificationsInstalling the CAT5 Suppression Ferrite Ferrite Installation RequiredSystem Diagram Intercom System DiagramWiring and Connections Metreau Entry Communicators Mounting and Installation MET-ECOM / MET-ECOM-D Installation OverviewDimensions Front View Mounting SpecificationsTop View Side ViewsTypical Installation Without Expansion Clips Typical Installation Without Expansion ClipsDevice and wall box must have an Earth ground Installing the Wall Box Without the Use of Tabs Recommended Cutout For Wall Box Wall Surface Installation Using Expansion ClipsReplacement drywall clip sets must be ordered from AMX Flat Surface Installation Points Installing Into a Flat Surface Using Mounting ScrewsRemoving the Device From the Wall Included in the Kit Using the Optional Surface Mount BoxProvides mounting specifications for the CB-MET-ECOMS Surface Mount Box SpecificationsInstalling the Metreau Entry Communicator Ferrite Installation RequiredMounting and Installation Using Zero Configuration Bonjour Zero-Configuration ClientConnecting In a Network With a Dhcp Server This case the serial number is 218001WHP2980023 Connecting In a Network Without a Dhcp ServerInternet Properties TCP/IP Properties dialog Using Zero Configuration Metreau Entry Communicators Configuration Manager Summary of Settings Page initial view Using the Configuration ManagerAccessing the Configuration Manager Command ButtonsSummary of Device Settings Summary of Device SettingsDevice Information IP Settings Rebooting the DeviceNetLinx Settings Checking the Firmware VersionConfiguration Page Network IP Settings Tab ConfigurationSetting the IP Address Setting the DNS AddressConfiguration Page Network IP Settings Tab Configuration Page NetLinx Settings Tab Setting the Icsp Connection to the NetLinx MasterConfiguration Page NetLinx Settings Tab Configuration Page User Settings Tab Setting a New Username and PasswordConfiguration Page User Settings Tab Device Utilities Device UtilitiesUtility Meta Information Image File Requirements Creating Display ImagesFile Upload ImagesSave the file as a .BMP image FIG TPDesign4 Resource Manager Creating Dynamic ImagesCreate Dynamic Image dialog Creating a New Dynamic ImageDeleting a Display Image From the Device Uploading a Display Image To The DeviceSetting Device Audio Audio/Video Page Audio Settings TabAudio/Video Page Audio Settings Tab Audio/VideoAudio/Video Page Video Settings Tab Audio/Video Page Video Settings TabCamera/Video Stream Configuration Video CodecAudio/Video Page Display Settings Tab Setting Device VideoAudio/Video Page Display Settings Tab Setting the Display Settings On The DeviceTouch Panel Intercom Commands SENDCOMMANDsTouch Panel Intercom Commands ProgrammingSTREAM-PLAY STREAM-GETSTREAM-STOP MOD?RTP, Rtcp Video and Audio Streaming Commands RTP, Rtcp Video and Audio Streaming CommandsSET Volume GET VolumeSET Audio GET GainFace Plate LED Commands Face Plate LED CommandsCamera Commands Camera CommandsGET CAM-CST SET CAM-CSTSET CAM-SAT GET CAM-SATLCD Commands LCD CommandsGET CAM-FLICK SET DISP-BANNERGET DISP-BRT SET DISP-BRTSET DISP-CST GET DISP-CSTSystem Commands CommandsCommands System CommandsGET DOOR-DESC SET DOOR-DESCUpgrading Firmware Before beginning the Upgrade processUpgrading Firmware via an IP Address Preparing the Master for communication via an IPVerifying and Upgrading the device firmware via an IP Assigning Communication Settings and TCP/IP SettingsSelect the device’s firmware file from the Files section FIG Panel Intercom Configuration Using the NetLinx ModuleIntercom Setup Incorporating an Intercom Panel Into Your NetLinx SystemSetting Intercom Auto Answer Setting the Intercom Session TimeoutDisabling All Doorbells Door SetupAssigning a Chime To a Doorbell Door Chime SetupAllowing a Panel To Be Monitored Advanced SetupAllowing a Panel To Monitor Naming a panelAnswering an incoming Intercom call Answering an Incoming Doorbell Call Someone At The DoorCreating Intercom Pages Advanced SetupEnding a Doorbell Call Name Description Channel Address PortCodeDoor Setup Door Chime SetupIntercom Demo Sample IntercomName Description Channel Address Level PortCode Panel Directory Room Name Name of a panel Setup SetupSomeone At The Door Someone At The DoorDoorbell Adjustments Popup Doorbell Adjustments popupCreating Popup Pages Door Answer Call popupIntercom Answer Call Popup Intercom Answer Call popupMore Time Popup More Time popupProgramming Metreau Entry Communicators It’s Your World Take Control