4.0Technical Data
4.1Gold Combi 24, 28 & 33 HE A
Appliance Type |
|
|
| C13 | C33 | C53 |
|
| |||||
Appliance Category | CAT I 2H |
|
|
| |||||||||
Heat Input CH (Net) | Max | Min |
|
| |||||||||
24 model |
| kW | 20.5 | 7 |
|
| |||||||
28 model |
| kW | 24.7 | 9 |
|
| |||||||
33 model |
| kW | 28.9 | 9.7 |
|
| |||||||
|
|
|
|
|
|
|
| ||||||
Heat Input CH (Gross) | Max | Min |
|
| |||||||||
24 model | kW | 22.7 | 7.8 |
|
| ||||||||
28 model | kW | 27.4 | 10 |
|
| ||||||||
33 model | kW | 32.1 | 10.8 |
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
| |
Heat Output CH |
|
|
| ||||||||||
|
|
|
|
|
|
|
|
|
| Max | Min |
|
|
24 model |
| kW | 20 | 6.8 |
|
| |||||||
28 model |
| kW | 24 | 8.7 |
|
| |||||||
33 model |
| kW | 28 | 9.4 |
|
| |||||||
|
|
|
|
|
|
|
|
|
|
| |||
Heat Output CH (Condensing) |
|
|
| ||||||||||
|
|
|
|
|
|
|
|
|
| Max | Min |
|
|
24 model |
| kW | 21 | 7.4 |
|
| |||||||
28 model |
| kW | 25.9 | 9.5 |
|
| |||||||
33 model |
| kW | 30.3 | 10.2 |
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
| ||
| Heat Input DHW (Net) | Max |
|
|
| ||||||||
| 24 model |
| kW | 24.7 |
|
|
| ||||||
| 28 model |
| kW | 28.9 |
|
|
| ||||||
| 33 model |
| kW | 34 |
|
|
| ||||||
|
|
|
|
|
|
| |||||||
Heat Input DHW (Gross) | Max |
|
|
| |||||||||
24 model |
| kW | 27.4 |
|
|
| |||||||
28 model |
| kW | 32.1 |
|
|
| |||||||
33 model |
| kW | 37.7 |
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
| |||
| Heat Output DHW | Max |
|
|
| ||||||||
| 24 model |
| kW | 24 |
|
|
| ||||||
| 28 model |
| kW | 28 |
|
|
| ||||||
| 33 model |
| kW | 33 |
|
|
| ||||||
|
|
|
|
|
|
|
|
| |||||
|
| Max Gas Rate (Natural Gas - G20) |
|
|
| ||||||||
|
|
|
|
|
|
| (After 10 mins) |
|
|
| |||
|
| 24 model |
| m3/h | 2.61 |
|
|
| |||||
|
| 28 model |
| m3/h | 3.1 |
|
|
| |||||
|
| 33 model |
| m3/h | 3.6 |
|
|
|
Inlet Pressure (Natural Gas - G20)
mbar | 20 |
|
|
| ||
|
|
|
|
|
| |
Injector (Natural Gas - G20) |
|
|
| |||
7.5mm (24&28 model) | 12mm(33 model) | |||||
|
|
|
|
| ||
Electrical Supply |
| 230V~ 50Hz | ||||
(Appliance must be connected to an | ||||||
earthed supply) |
|
|
|
| ||
|
|
|
|
|
|
|
Power Consumption |
|
|
|
| ||
155W (24 & 28 model) | 160W (33 model) | |||||
|
|
|
|
|
|
|
Electrical Protection |
|
|
|
| ||
|
|
| IPX0D |
|
|
|
|
|
|
| |||
External Fuse Rating |
| 3A | ||||
|
|
|
|
|
|
|
Internal Fuse Rating |
| F2L |
Condensate Drain
To accept 21.5mm (3/4 in) plastic waste pipe
Flue Terminal | Diameter |
| 100mm | |||
Dimensions | Projection | 125mm | ||||
|
|
|
|
| ||
Connections |
|
| copper tails | |||
Gas Supply |
|
| - | 22mm | ||
Central Heating Flow |
|
| - | 22mm | ||
Central Heating Return | - | 22mm | ||||
Cold Water Mains Inlet | - | 15mm | ||||
DHW Flow |
|
| - | 15mm | ||
Pressure Relief Discharge | - | 15mm | ||||
|
|
|
|
|
| |
Outercase Dimensions |
|
| ||||
Casing Height |
|
|
| - 780mm | ||
Overall Height Inc Flue Elbow |
| - 965mm | ||||
Casing Width |
|
|
| - 450mm | ||
Casing Depth |
|
|
| - 345mm | ||
|
|
|
|
|
|
|
Clearances |
|
|
|
| ||
Above Casing | 200 mm Min |
| ||||
Below Casing | 150 mm Min* |
| ||||
Front | 450 mm Min (For Servicing) | |||||
Front | 5 mm Min (In Operation) | |||||
L.H. Side | 5 mm Min |
| ||||
R.H. Side | 5 mm Min (In Operation) |
*This is the MINIMUM recommended dimension. Greater clearance than this will aid installation and maintenance.
Weights (kg) |
|
|
|
| (24) | (28) | (33) |
Packaged Boiler Carton | 48.6 | 49.2 | 51 |
Installation Lift Weight | 43.6 | 44.2 | 46 |
NOx Class |
| 5 |
|
| |
Central Heating Primary Circuit |
| ||||
Pressures |
|
|
|
| |
|
|
|
|
| bar |
Safety Discharge |
|
|
| 3 | |
Max Operating |
|
|
| 2.5 | |
Min Operating |
|
|
| 0.5 | |
Recommended Operating Range | |||||
|
|
|
|
|
|
DHW Circuit |
| bar |
| ||
Pressures |
|
|
|
| |
Max Operating |
| 8 |
|
| |
Min Operating |
| 0.15 |
| ||
|
|
|
|
|
|
Flow Rates | (24) | (28) | (33) | ||
|
| l/min | l/min | l/min | |
DHW Flow Rate |
|
|
|
| |
@ 30o C Rise | 11.43 | 13.3 | 15.7 | ||
DHW Flow Rate |
|
|
|
| |
@ 35o C Rise | 9.8 | 11.5 | 13.5 | ||
Min Working |
|
|
|
| |
DHW Flow Rate | 2 | 2 |
| 2 |
IMPORTANT: Where Low Flow Taps or Fittings are intended to be used in the DHW system connected it is strongly recommended that the DHW flow rate DOES NOT fall below 2.5l/min. This will ensure reliable operation of the DHW function.
Pump |
|
|
|
Available Head | See graph below |
| |
|
| ||
Expansion Vessel | - (For Central Heating | ||
only. Integral with appliance) |
|
| |
|
| bar |
|
Min | 0.5 |
| |
|
| (24,28) | (33) |
Max Capacity of |
| litre | litre |
CH System |
| 125 | 155 |
Primary Water Content |
|
| |
of Boiler (unpressurised) | 2.5 | 2.8 |
Temperatures
C.H. Flow Temp (adjustable)
25°C to 80°C max (± 5°C)
D.H.W. Flow Temp (adjustable)
35°C to 60°C max (± 5°C) dependent upon flow rate
NOTE: All data in this section are nominal values and subject to normal production tolerances.
SEDBUK Declaration
The efficiency is 91.1% (all models)
This value is used in the UK Government’s Standard Assessment Procedure (SAP) for energy rating of dwellings. The test data from which it has been calculated has been certified by 0087.
Pump - Available Head
| 5.5 | |
| 5 | |
| 4.5 | |
| 4 | |
| 3.5 | |
| 3 | |
(wg) | 2.5 | |
| ||
Metre | 2 | |
1.5 | ||
| ||
| 1 |
0.5
0
0 | 200 | 400 | 600 | 800 | 1000 | 1200 |
10© Baxi Heating UK Ltd 2012
Flow Rate (l/h)