12 | GAS INSTRUCTIONS |
|
|
•Do not use a damaged LP cylinder. Dented or rusty LP cylinders or LP cylinders
with a damaged valve may be hazardous and should be replaced with a new one immediately.
Liquid Propane (LP) Cylinder(s)
•The joint where the hose connects to the LP cylinder must be leak tested each time the LP cylinder is reconnected. For example, test each time the LP cylinder is refi lled.
•Be sure the regulator is mounted with the small vent hole pointed downward so that it will not collect water. This vent should be free of dirt, grease, bugs etc.
•The gas connections supplied with your Weber® gas barbecue have been designed and tested to meet 100% CSA and ANSI requirements.
1
DOT 4BA240
00/06
WARNING: Replacement LP tanks must match the regulator connection supplied with this barbecue.
Liquid Propane Cylinder requirements
•Check to be sure cylinders have a D.O.T. certifi cation (1), and date tested (2) is within fi ve years. Your LP gas supplier can do this for you.
•All LP tank supply systems must include a collar to protect the cylinder valve.
•The LP cylinder must be a
•The cylinder should be constructed and marked in accordance with the
Specifi cations for LP - Gas Cylinders of the U.S. Department of Transportation (D.O.T.) or the National Standard of Canada,
In Canada
Liquid Propane Cylinder requirements
Note: Your retailer can help you match a replacement tank to your barbecue.
•The LP cylinder must be constructed and marked in accordance with the specifi cations for LP gas cylinders, T.C.
2
TANK CABINET TROUBLESHOOTING
PROBLEM | CHECK | CURE |
|
|
|
Burners do not light. | Is gas supply off? | Turn supply on. |
|
|
|
Flame is low in HIGH position. | Is fuel hose bent or kinked? | Straighten fuel hose. |
|
|
|
Burners do not light | The excess fl ow safety device, which is part of | To reset the excess flow safety device turn all burner control |
flame in the HIGH position | the barbecue to cylinder connection, may have | knobs and the cylinder valve OFF. Disconnect the regulator |
only reaches 250˚ to 300˚F in the HIGH position. | activated. | from the cylinder. Turn burner control knobs to HIGH. Wait at |
|
| least 1 minute. Turn burner control knobs OFF. Reconnect |
|
| the regulator to the cylinder. Turn cylinder valve on slowly. |
|
| Refer to “Lighting Instructions”. |
|
|
|
If problems cannot be corrected by using these methods, please contact the Customer Service Representative in your area using the contact information on our web site. Log onto www.weber.com®.
WEBER-STEPHEN PRODUCTS CO.
www.weber.com®
©2005- The following trademarks are registered in the name of
Matchless Flame, Zimbabwe; Weber, Kettle Confi guration, Kettle Silhouette . | Printed in USA. |
WWW.WEBER.COM®