Operating Instructions
Operating Instructions
Controls
The controls will look like one of the following.
FAN SPEED
•Every time you push this button, it advances the setting as follows: {High → Low → Med → High}
Cool |
| F1 LOW | 'F |
Energy |
| F2 MED |
|
| F3 HIGH |
| |
Saver |
|
|
|
Fan |
|
|
|
| Timer | TEMP |
|
|
|
|
MODE TIMER SPEED POWER
TIMER
-
•You will usually use
•If unit is running, use Timer to set number of hours until
•For your sleeping comfort, once Time is set, the Temperature setting will raise 2°F after 30 min., and once again after another 30 min.
•Push Timer button to advance setting from 1Hour → 2Hours → ...
→ 24 Hours maximum.
-START TIME
•If unit is off, use Timer to set number of hours before unit starts.
•Push Timer button to advance setting from 1Hour → 2Hours → ...
→ 24 Hours maximum.
REMOTE CONTROL SIGNAL RECEIVER
TEMPERATURE SETTING
•Use this button to automatically control the temperature of the room.
The temperature can be set within a range of 60°F to 86°F by increments of 1°F.
•The setting appears in the display.
POWER
•To turn the air conditioner ON, push this button. To turn the air conditioner OFF, push the button again.
•This button takes priority over any other button.
•When you first turn it on, the unit is in cool
mode, High fan speed, Temperature setting at 72°F.
MODE
-Push this button to shift mode of operation from COOL → ENERGY SAVER → FAN.
-COOL:
•Fan runs continually for normal cooling operation.
-ENERGY SAVER:
•The fan stops when the compressor stops cooling. Approximately every 3 minutes the fan will turn on and the unit will check the room air temperature to determine if cooling is needed.
-FAN:
•
AUTO RESTART
When power is restored after an electrical power failure, the unit will begin to run at its last setting.