User Settings & Control System Menus

User Settings & Control System Menus

Temperatures

Operating Set Point And Differential Adjustment

The Operating Set Point is adjustable from 90°F (42°C) to 180°F (82°C) for commercial and 160°F (71°C) on residential models. The factory setting is 120°F (49°C). The Differential is adjustable from 2° to 20°. The factory setting is 8°. These user settings are accessed from the Temperatures menu. These instructions explain how to adjust these settings and navigate the control system.

When the water temperature sensed by the control system from the Temperature Probe reaches the Operating Set Point the control system will end the heating cycle. A heating cycle will be activated again when the sensed water temperature drops below the Operating Set Point minus the Differential setting.

Note: Set the Operating Set Point to the lowest setting which produces an acceptable hot water supply for most efficient use. Lower Differential settings may cause excessive heating cycles (short-cycling) which can cause premature failure of components such as the Igniter. Set the Differential at the highest setting which produces an acceptable hot water supply to prevent short cycling.

Description/Action

Display

 

 

From the Desktop screen, press the Operational Button under

 

 

 

MANUFACTURER / MODEL INFORMATION

 

MENU. The "Main Menu" screen will be displayed.

 

 

 

 

 

Tank Temperature

120°F

 

Operating Set Point

120°F

 

Status: Standby

 

 

 

 

 

MENU

 

HELP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The Main Menu is where all control system menus are listed,

 

 

 

 

 

 

 

 

 

 

 

 

Main Menu

 

 

 

 

see Table 11 for a complete list and description of control

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

system menus. Use the Up and Down Buttons to view all

 

Temperatures

 

 

 

 

 

 

 

 

 

 

control system menus from the Main Menu.

 

 

 

 

 

 

 

 

 

 

Heater Status

 

 

 

 

 

 

 

 

 

 

 

 

With Temperatures menu selected (highlighted in black) in

 

Display Settings

 

 

 

 

the Main Menu screen, press the Operational Button under

 

Heater Information

 

 

 

 

“SELECT” to enter the Temperatures menu.

 

 

 

 

 

If the Temperatures menu is not selected use the Up and Down

 

Current Fault

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Buttons to select this menu item.

 

 

 

 

 

 

 

 

 

 

 

SELECT

 

BACK

HELP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

With the Operating Set Point selected in the Temperatures

Temperatures

 

menu, press the Operational Button underneath “CHANGE” to

 

Operating Set Point

 

120°F

activate the adjustment mode for this menu item.

 

If Operating Set Point is not selected use the Up and Down

Differential

 

8°F

Tank Temperature

 

120°F

Buttons to select this menu item.

Tank Probe Offset

 

0°F

 

 

Note: Higher Temperature settings increase wear and

 

 

 

operating costs. Set the Operating Set Point to the lowest

 

 

 

setting which produces an acceptable hot water supply. This

 

 

 

will always provide the most energy efficient operation and

CHANGE

BACK

HELP

longer life.

 

 

 

With the adjustment mode for the Operating Set Point activated

Temperatures

 

the selection bar will change from a black fill to a black outline.

 

Operating Set Point

 

140°F

Use the Up and Down Buttons to change the current setting.

 

Differential

 

8°F

Press the Operational Button under "UPDATE" to save the

Tank Temperature

 

120°F

Tank Probe Offset

 

0°F

new setting. Press the Operational Button under "CANCEL" to

 

 

 

 

discard changes and return to the previously saved setting.

 

 

 

Note: Use this same procedure to change the Differential

 

 

 

setting and other adjustable user settings in the control system

UPDATE

 

CANCEL

menus.

 

 

 

 

40

Image 40
Contents For Your Safety whenever maintenance adjustment or service is requiredRESIDENTIAL GAS WATER HEATERS Instruction Manualtable of contents APPROVALS safe installation, use and serviceDANGER general safety information PrecautionsImproper installation, use and service may result in property damage Explosion Hazardgeneral safety information General Safety Information Fire or Explosion HazardBreathing Hazard - Carbon Monoxide Gas Electrical Shock HazardPreparing For The Installation introductionAbbreviations Used Qualificationsfeatures and components REPLACEMENT PARTS AND DELIMING PRODUCTSGet To Know Your Water Heater - Gas Models Control Assemblyinstallation consideration Rough In DimensionsTable 1 - Rough-In-Dimensions Table 2 - Capacity, Gas and Electrical CharacteristicsProperty Damage Hazard Locating The Water HeaterInsulation Blankets Combustion Air and VentilationUnconfined Space Confined Space Fresh Air Openings For Confined SpacesOutdoor Air Through Two Openings Outdoor Air Through One OpeningOutdoor Air Through Two Horizontal Ducts Air From Other Indoor Spacesinstalling the new water heater Power SupplyChemical Vapor Corrosion Water PipingMixing Valves Dishwashing MachinesSpace Heating and Potable Water System Time to Produce 2nd & 3rdThermal Expansion Closed Water SystemsT & P Valve and Pipe Insulation if supplied Water Damage Hazard Explosion HazardTemperature-Pressure Relief Valve T&P Valve Discharge Pipe RequirementsGas Piping Supply Gas RegulatorCondensate Piping SEDIMENT TRAPSHigh Altitude Installations Filling the Water HeaterVenting If using 2” inch vent pipeIf using 3” inch vent pipe VENT PIPE TERMINATIONINSTALLATION OF VENT SYSTEM VENT TERMINAL INSTALLATION, SIDEWALLInstallation Requirements - Commonwealth of Massachusetts Installation of Carbon Monoxide DetectorsCommonwealth of Massachusetts Approved Carbon Monoxide DetectorsTermination Clearances Sidewall Power Vent POWER VENTTermination Clearances Sidewall Direct Vent Installation Sequence SEQUENCE OF INSTALLATIONS, FIGURE 15AVent Termination - Figure 15A DIRECT VENT terminal installation Figure 15BVERTICAL VENT TERMINAL INSTALLATION Flat Roof InstallationConcentric vent installation SAFETY CONSIDERATIONSINSTALLATION PROCEDURE 1 ROOF TERMINATION, see Figure Table 6 - KIT COMPONENTSPROCEDURE 2 SIDE WALL TERMINATION, see Figure CONCENTRIC TERMINATION FLAT ROOF CLEARANCEFigure 23A MULTI-CONCENTRIC VENT TERMINATIONS direct vent diagram Vent Pipe Preparation RECOMMENDED BRUSH* SIZE FOR PRIMER AND CEMENT APPLICATIONS1. INITIAL PREPARATION 2. SELECTION OF MATERIALSD. Inspection, cleaning, priming STEP E F. Joint assemblySTEP F G. Cleanup and joint movement B. DeburringControls and Switches BLOWER PROVER SWITCHBLOCKED EXHAUST SWITCH BLOCKED INTAKE SWITCHPower Vent Wiring Schematic - Figure WIRE TO GROUND CHECK INDICATES ZERO VOLTAGETHIS WATER HEATER IS POLARITY SENSITVE BEFORE APPLYING ELECTRICITY TO THIS HEATER BE CERTAIN THAT SUPPLY NEUTRALFOR YOUR SAFETY READ BEFORE LIGHTING OPERATING INSTRUCTIONSTO TURN OFF GAS TO APPLIANCE WARNING TURN OFF ALL ELECTRIC POWER BEFORE SERVICINGtemperature regulation HI LIMIT SWITCH ECOTime to Produce 2nd & 3rd Degreeadjust user settings control system operationOperating Set Point 120FDescription IconStatus Icons State MenuOperating States Control System MenusUser Settings & Control System Menus MENUHELP Main Menu140F Heater StatusDisplay Settings Heater InformationTemperature Units Backlight DelayFault History Fault OccurrenceRestore Factory Defaults Blocked ExhaustService Contact Information Show Contact InformationChange Contact Name Current Contact Infofor your information Start Up ConditionsOperational Conditions SMOKE/ODORperiodic maintenance Venting System InspectionAnode Rod Inspection Temperature-Pressure Relief Valve OperationService Draining and FlushingBurn harzard Hot water discharge Keep hands clear of drain valve dischargemaintenance Temperature-Pressure Relief Valve Testleakage checkpoints troubleshooting Installation ChecklistWater Heater Location VentingSequence Of Operation Flow Chart YESNOOperational Problems Fault and Alert ConditionsBurn Hazard Replacement PartsResetting Control System Lock Outs Electrical Shock HazardDiagnostic Checks AC Reversed Ignition FailureLow Igniter Current Blocked ExhaustBlower Prover Failure Blower Prover OpenBlocked Air Intake Energy Cut Out ECOPage Page Page LIMITED RESIDENTIAL GAS WARRANTY SERVICE AND LABOR RESPONSIBILITYCLAIM PROCEDURE CONDITIONS AND EXCEPTIONSPO Box 1597, 500 Princeton Road Johnson City, TN American Water Heater Product Service and SupportCopyright 2011 American Water Heaters. All rights reserved