American Water Heater VG6250T100 installation consideration, Rough In Dimensions, A

Page 9
installation consideration

installation consideration

Rough In Dimensions

FIGURE 1A.

Table 1 – Rough-In-Dimensions

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Units

 

 

A

 

B

 

C

 

 

D

 

 

E

 

F

 

 

G

 

 

H

I

 

 

 

 

 

 

Inches

 

66.75

 

49.25

 

22.00

 

15.75

 

3.00

 

8.00

 

8.00

 

62.00

 

65.00

 

 

 

 

 

 

cm

 

169.5

 

125.09

 

55.88

 

40.00

 

7.62

 

20.32

 

20.32

 

157.48

 

165.1

 

 

 

 

 

 

Top/Side Inlet and Outlet: 3/4” NPT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Gas Inlet: 1/2” NPT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table 2 – Capacity, Gas and Electrical Characteristics

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Approximate Capacity

 

 

Manifold Pressure

 

Electrical Characteristics

 

 

 

 

 

 

 

 

 

 

U.S. Gals.

 

Liters

 

Gas Type

 

“WC

 

kPA

 

Volts/Hz

 

Amperes

 

 

 

 

 

 

 

 

 

 

50

 

 

 

189

 

 

 

Nat./LP

 

 

0”

 

 

0”

 

120/60

 

 

 

<5

 

 

 

 

 

 

 

 

 

 

All models - Maximum Supply Pressure: 14 inches W.C. (3.48kPa)

 

 

 

 

 

 

 

 

 

 

 

 

 

Minimum Supply Pressure for Natural Gas: 3.50” (.87kPa)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Minimum Supply Pressure for Propane Gas: 8.00” (1.99kPa)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Minimum pressure must be maintained under both load and no load (dynamic and static) conditions.

 

 

 

Table 3 – Recovery Capacities - U.S. Gallons/Hr. and Liters/Hr. at Temperature Rise Indicated

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Input

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Recovery Capacities

 

 

 

 

 

 

Rating

 

Rating

 

Temp.

F

 

30

 

 

40

 

50

 

60

 

70

 

 

80

 

90

100

110

120

130

140

(Btu/hr)

 

(kW)

 

Rise

 

C

 

17

 

 

22

 

28

 

33

 

 

39

 

 

44

 

50

56

61

67

72

78

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100,000

 

29.3

 

 

 

GPH

 

 

387

 

 

291

 

233

 

194

 

166

 

145

 

129

116

106

97

90

83

 

 

 

 

LPH

 

 

1465

 

1102

 

882

 

734

 

 

628

 

549

 

488

439

401

367

341

314

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Recovery capacity based on 96% thermal efficiency

9

Image 9
Contents whenever maintenance adjustment or service is required For Your SafetyRESIDENTIAL GAS WATER HEATERS Instruction Manualtable of contents safe installation, use and service APPROVALSDANGER Precautions general safety informationImproper installation, use and service may result in property damage Explosion Hazardgeneral safety information Fire or Explosion Hazard General Safety InformationBreathing Hazard - Carbon Monoxide Gas Electrical Shock Hazardintroduction Preparing For The InstallationAbbreviations Used QualificationsREPLACEMENT PARTS AND DELIMING PRODUCTS features and componentsGet To Know Your Water Heater - Gas Models Control AssemblyRough In Dimensions installation considerationTable 1 - Rough-In-Dimensions Table 2 - Capacity, Gas and Electrical CharacteristicsLocating The Water Heater Property Damage HazardCombustion Air and Ventilation Insulation BlanketsUnconfined Space Fresh Air Openings For Confined Spaces Confined SpaceOutdoor Air Through Two Openings Outdoor Air Through One OpeningAir From Other Indoor Spaces Outdoor Air Through Two Horizontal DuctsPower Supply installing the new water heaterChemical Vapor Corrosion Water PipingDishwashing Machines Mixing ValvesSpace Heating and Potable Water System Time to Produce 2nd & 3rdClosed Water Systems Thermal ExpansionT & P Valve and Pipe Insulation if supplied Explosion Hazard Water Damage HazardTemperature-Pressure Relief Valve T&P Valve Discharge Pipe RequirementsSupply Gas Regulator Gas PipingCondensate Piping SEDIMENT TRAPSFilling the Water Heater High Altitude InstallationsIf using 2” inch vent pipe VentingIf using 3” inch vent pipe VENT PIPE TERMINATIONVENT TERMINAL INSTALLATION, SIDEWALL INSTALLATION OF VENT SYSTEMInstallation of Carbon Monoxide Detectors Installation Requirements - Commonwealth of MassachusettsCommonwealth of Massachusetts Approved Carbon Monoxide DetectorsPOWER VENT Termination Clearances Sidewall Power VentTermination Clearances Sidewall Direct Vent SEQUENCE OF INSTALLATIONS, FIGURE 15A Installation SequenceVent Termination - Figure 15A DIRECT VENT terminal installation Figure 15BFlat Roof Installation VERTICAL VENT TERMINAL INSTALLATIONSAFETY CONSIDERATIONS Concentric vent installationINSTALLATION PROCEDURE 1 ROOF TERMINATION, see Figure Table 6 - KIT COMPONENTSCONCENTRIC TERMINATION FLAT ROOF CLEARANCE PROCEDURE 2 SIDE WALL TERMINATION, see FigureFigure 23A MULTI-CONCENTRIC VENT TERMINATIONS direct vent diagram RECOMMENDED BRUSH* SIZE FOR PRIMER AND CEMENT APPLICATIONS Vent Pipe Preparation1. INITIAL PREPARATION 2. SELECTION OF MATERIALSSTEP E F. Joint assembly D. Inspection, cleaning, primingSTEP F G. Cleanup and joint movement B. DeburringBLOWER PROVER SWITCH Controls and SwitchesBLOCKED EXHAUST SWITCH BLOCKED INTAKE SWITCHWIRE TO GROUND CHECK INDICATES ZERO VOLTAGE Power Vent Wiring Schematic - FigureTHIS WATER HEATER IS POLARITY SENSITVE BEFORE APPLYING ELECTRICITY TO THIS HEATER BE CERTAIN THAT SUPPLY NEUTRALOPERATING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTINGTO TURN OFF GAS TO APPLIANCE WARNING TURN OFF ALL ELECTRIC POWER BEFORE SERVICINGHI LIMIT SWITCH ECO temperature regulationTime to Produce 2nd & 3rd Degreecontrol system operation adjust user settingsOperating Set Point 120FIcon DescriptionStatus Icons Menu StateOperating States Control System MenusMENU User Settings & Control System MenusHELP Main MenuHeater Status 140FHeater Information Display SettingsTemperature Units Backlight DelayFault Occurrence Fault HistoryRestore Factory Defaults Blocked ExhaustShow Contact Information Service Contact InformationChange Contact Name Current Contact InfoStart Up Conditions for your informationOperational Conditions SMOKE/ODORVenting System Inspection periodic maintenanceAnode Rod Inspection Temperature-Pressure Relief Valve OperationDraining and Flushing ServiceBurn harzard Hot water discharge Keep hands clear of drain valve dischargeTemperature-Pressure Relief Valve Test maintenanceleakage checkpoints Installation Checklist troubleshootingWater Heater Location VentingYESNO Sequence Of Operation Flow ChartFault and Alert Conditions Operational ProblemsBurn Hazard Replacement PartsElectrical Shock Hazard Resetting Control System Lock OutsDiagnostic Checks Ignition Failure AC ReversedLow Igniter Current Blocked ExhaustBlower Prover Open Blower Prover FailureBlocked Air Intake Energy Cut Out ECOPage Page Page SERVICE AND LABOR RESPONSIBILITY LIMITED RESIDENTIAL GAS WARRANTYCLAIM PROCEDURE CONDITIONS AND EXCEPTIONSAmerican Water Heater Product Service and Support PO Box 1597, 500 Princeton Road Johnson City, TNCopyright 2011 American Water Heaters. All rights reserved