Setup - Modbus communication parameters

Quick Installation Guide

March 2013

 

 

12.The Basic Configuration with the Radar Master Wizard is now finished. Proceed with the Device Specific Setup to see which additional configuration is needed. You may be required to calibrate Vapor Compensation, to set up Probe End Projection, or to perform a Trim Near Zone depending on type of the device, application, and functions available.

For further information, see the Rosemount 5300 Series Reference Manual (Document No. 00809-0100-4530).

Step 1: Run Wizard

Step 2: Device specific setup

Step 3: Restart the device

Step 4: View live values from the device

Step 5: Make a complete backup of the device

For Signal Quality Metrics information and further configuration, see the Rosemount 5300 Series Reference Manual (Document No. 00809-0100-4530).

Setup - Modbus communication parameters

For transmitters with the Modbus option, do the following to configure the communication parameters:

1. In the Setup menu select General. The following window appears.

2.Choose the Communication tab.

3.Click Modbus Setup.

4. Enter the desired Modbus communication settings.

20

Image 20
Contents 00825-0100-4530,Rev EC March Quick Installation GuideSuperior Performance Guided Wave Radar Level and Interface TransmitterProbes with non-conductingsurfaces About this guideQuick Installation Guide Contents MarchSwitch HART revision mode Step 1: Confirm system readinessConfirm HART revision capability Confirm correct Device DriverStep 2 Mount the transmitter head/probe Tank connection with flangeThreaded tank connection Tri-Clamptank connectionBracket mounting, on pipe Step 2 continuedBracket mounting, on wall Remote housing Step 2 continuedStep 3 Connect the wiring GroundingTo connect the transmitter Terminal blockNon-intrinsicallysafe power supply Intrinsically safe power supplyHART communication Step 3 continuedTransient protection terminal block Quick Installation GuidePower PowerLoad limitations Quick Installation GuideNon-HazardousInstallations InstallationsIntrinsically safe power supply Step 3 continued FOUNDATION fieldbusNon-intrinsicallysafe power supply RS-485with Modbus communication Power Consumption 0.5 W with HART address =Quick Installation Guide Step 3 continuedStep 4 Configure Installing the Rosemount Radar Master softwareRun Wizard 1Only for HART communicationFOUNDATION fieldbus parameters FOUNDATION fieldbus parameters FOUNDATION fieldbus parameters Setup - Modbus communication parameters 3.Click Modbus SetupConfiguration Safety Instrumented Systems 4-20mA onlyInstallation Alarm and saturation levels Table 3. Alarm levels and operation valuesDamping Write protectionProof test Operation and maintenanceSite acceptance Specifications InspectionReferences Visual inspectionSafety Instrumented Systems SIS Product certificationsEU conformity North-AmericancertificationsCanadian Standards Association CSA approvals Quick Installation GuideDual seal maintenance I5, IE1 Intrinsically safe and FISCO modelEuropean certifications ATEX approvalsMarch Special conditions for safe useBrazilian certifications INMETRO approvalsQuick Installation Guide Special conditions for safe useChinese certifications MarchI21 Intrinsically safe IB1 FISCO modelJapanese certifications Quick Installation GuideIC1 FOUNDATION fieldbus FISCO model N3 Type nIECEx certifications IECEx approvalsMarch Special conditions for safe useOther certifications Overfill protectionQuick Installation Guide Suitability for intended useEC Declaration of Conformity Figure 1. EC Declaration of Conformity - pageQuick Installation Guide MarchMarch Figure 2. EC Declaration of Conformity - pageQuick Installation Guide March Figure 3. EC Declaration of Conformity - pageQuick Installation Guide Quick Installation Guide 00825-0100-453000825-0100-4530,Rev EC March Emerson Process Management Rosemount Measurement