Emerson 00825-0100-4530 Rev EC European certifications, ATEX approvals, March, E11 Flameproof

Page 27
European certifications

March 2013

Quick Installation Guide

European certifications

ATEX approvals

Special conditions for safe use (X)

The intrinsically safe circuits do not withstand the 500 V AC test as specified in IEC 60079-11 clause 6.4.12.

Impact and friction hazards need to be considered according to EN 60079-0 clause 8.1.2 when the transmitter and part of antennas exposed to the exterior atmosphere of the tank is made with light metal alloys and of category II 1G EPL Ga.

The Ex ia version of model 5300 FISCO field device may be supplied by an [Ex ib] FISCO power supply when the power supply is certified with three separate safety current limiting devices and voltage limitation which meets the requirements for type Ex ia.

E11 Flameproof:

Nemko 04ATEX1073X

ATEX approvals II 1/2 G T4

II 1D T79 °C2

Ex ia/db ia IIC T4 Ga/Gb (-40 °C < Ta < +70 °C3)

Ex ta IIIC T79 °C2 (-40 °C < Ta < +70 °C3)

Um = 250 V

Approval valid for HART, FOUNDATION fieldbus, and Modbus options.

I1, IA1 Intrinsically safe and FISCO model:

Nemko 04ATEX1073X Special conditions for safe use (X) II 1 G T4 or

E11 Flameproof: II 1/2 G T4 II 1 D T79 °C2

Ex ia IIC T4 (-50 °C < Ta < +70 °C3)

Ex ia/ib IIC T4 Ga/Gb (-50 °C < Ta < +60 °C) Ex ta IIIC T79 °C2 (-50 °C < Ta < +70 °C3)

4-20 mA/HART model: Ui = 30 Vdc, Ii = 130 mA, Pi = 1.0 W, Ci = 7.26 nF, Li = 0 H.

FOUNDATION fieldbus model: Ui = 30 Vdc, Ii = 300 mA, Pi = 1.5 W, Ci = 4.95 nF, Li = 0 H.

FISCO model: Ui = 17.5 Vdc, Ii = 380 mA, Pi = 5.32 W, Ci = 4.95 nF, Li < 1 μH.

Installation Drawing: 9240 030-938

Approval valid for HART, FOUNDATION fieldbus, and FISCO options.

N11 Type n:

I1, IA1 Intrinsically safe and FISCO model: II 3G Ex nAnL IIC T4 Gc (-50 °C < Ta < +70 °C3)

N11 Type n: II 3G Ex nL IIC T4 Gc (-50 °C < Ta < +70 °C3) Nemko 10ATEX1072

4-20 mA/HART model: Un = 42.4 V

FOUNDATION fieldbus model: Un = 32 V

Approval valid for HART and FOUNDATION fieldbus options.

1)Ordering information code for Product Certifications, see the Rosemount 5300 Series Product Data Sheet (Document No. 00813-0100-4530) or the Rosemount 5300 Series Reference Manual

(Document No. 00809-0100-4530).

2)+69 °C with FOUNDATION fieldbus or FISCO option.

3)+60 °C with FOUNDATION fieldbus or FISCO option.

27

Image 27
Contents Level and Interface Transmitter 00825-0100-4530,Rev EC MarchQuick Installation Guide Superior Performance Guided Wave RadarAbout this guide Quick Installation GuideProbes with non-conductingsurfaces March ContentsConfirm correct Device Driver Switch HART revision modeStep 1: Confirm system readiness Confirm HART revision capabilityTri-Clamptank connection Step 2 Mount the transmitter head/probeTank connection with flange Threaded tank connectionStep 2 continued Bracket mounting, on wallBracket mounting, on pipe Step 2 continued Remote housingGrounding Step 3 Connect the wiringTerminal block To connect the transmitterStep 3 continued Non-intrinsicallysafe power supplyIntrinsically safe power supply HART communicationPower Transient protection terminal blockQuick Installation Guide PowerInstallations Load limitationsQuick Installation Guide Non-HazardousInstallationsStep 3 continued FOUNDATION fieldbus Non-intrinsicallysafe power supplyIntrinsically safe power supply Step 3 continued RS-485with Modbus communicationPower Consumption 0.5 W with HART address = Quick Installation GuideInstalling the Rosemount Radar Master software Step 4 Configure1Only for HART communication Run WizardFOUNDATION fieldbus parameters FOUNDATION fieldbus parameters FOUNDATION fieldbus parameters 3.Click Modbus Setup Setup - Modbus communication parametersSafety Instrumented Systems 4-20mA only InstallationConfiguration Write protection Alarm and saturation levelsTable 3. Alarm levels and operation values DampingOperation and maintenance Site acceptanceProof test Visual inspection SpecificationsInspection ReferencesNorth-Americancertifications Safety Instrumented Systems SISProduct certifications EU conformityI5, IE1 Intrinsically safe and FISCO model Canadian Standards Association CSA approvalsQuick Installation Guide Dual seal maintenanceSpecial conditions for safe use European certificationsATEX approvals MarchSpecial conditions for safe use Brazilian certificationsINMETRO approvals Quick Installation GuideIB1 FISCO model Chinese certificationsMarch I21 Intrinsically safeN3 Type n Japanese certificationsQuick Installation Guide IC1 FOUNDATION fieldbus FISCO modelSpecial conditions for safe use IECEx certificationsIECEx approvals MarchSuitability for intended use Other certificationsOverfill protection Quick Installation GuideMarch EC Declaration of ConformityFigure 1. EC Declaration of Conformity - page Quick Installation GuideFigure 2. EC Declaration of Conformity - page Quick Installation GuideMarch Figure 3. EC Declaration of Conformity - page Quick Installation GuideMarch Emerson Process Management Rosemount Measurement Quick Installation Guide00825-0100-4530 00825-0100-4530,Rev EC March