Emerson 00825-0100-4530 Rev EC manual Run Wizard, 1Only for HART communication

Page 16
Image 16
Contents 00825-0100-4530,Rev EC March Quick Installation GuideSuperior Performance Guided Wave Radar Level and Interface TransmitterQuick Installation Guide About this guideProbes with non-conductingsurfaces Contents MarchSwitch HART revision mode Step 1: Confirm system readinessConfirm HART revision capability Confirm correct Device DriverStep 2 Mount the transmitter head/probe Tank connection with flangeThreaded tank connection Tri-Clamptank connectionBracket mounting, on wall Step 2 continuedBracket mounting, on pipe Remote housing Step 2 continuedStep 3 Connect the wiring GroundingTo connect the transmitter Terminal blockNon-intrinsicallysafe power supply Intrinsically safe power supplyHART communication Step 3 continuedTransient protection terminal block Quick Installation GuidePower PowerLoad limitations Quick Installation GuideNon-HazardousInstallations InstallationsNon-intrinsicallysafe power supply Step 3 continued FOUNDATION fieldbusIntrinsically safe power supply RS-485with Modbus communication Power Consumption 0.5 W with HART address =Quick Installation Guide Step 3 continuedStep 4 Configure Installing the Rosemount Radar Master softwareRun Wizard 1Only for HART communicationFOUNDATION fieldbus parameters FOUNDATION fieldbus parameters FOUNDATION fieldbus parameters Setup - Modbus communication parameters 3.Click Modbus SetupInstallation Safety Instrumented Systems 4-20mA onlyConfiguration Alarm and saturation levels Table 3. Alarm levels and operation valuesDamping Write protectionSite acceptance Operation and maintenanceProof test Specifications InspectionReferences Visual inspectionSafety Instrumented Systems SIS Product certificationsEU conformity North-AmericancertificationsCanadian Standards Association CSA approvals Quick Installation GuideDual seal maintenance I5, IE1 Intrinsically safe and FISCO modelEuropean certifications ATEX approvalsMarch Special conditions for safe useBrazilian certifications INMETRO approvalsQuick Installation Guide Special conditions for safe useChinese certifications MarchI21 Intrinsically safe IB1 FISCO modelJapanese certifications Quick Installation GuideIC1 FOUNDATION fieldbus FISCO model N3 Type nIECEx certifications IECEx approvalsMarch Special conditions for safe useOther certifications Overfill protectionQuick Installation Guide Suitability for intended useEC Declaration of Conformity Figure 1. EC Declaration of Conformity - pageQuick Installation Guide MarchQuick Installation Guide Figure 2. EC Declaration of Conformity - pageMarch Quick Installation Guide Figure 3. EC Declaration of Conformity - pageMarch Quick Installation Guide 00825-0100-453000825-0100-4530,Rev EC March Emerson Process Management Rosemount Measurement