Hoshizaki KM-901MWH, KM-901MAH, KM-901MRH/3 service manual Contents

Page 3

IMPORTANT

This manual should be read carefully before the icemaker is serviced or maintenance operations are performed. Only qualified service technicians should install, service, and maintain the icemaker. Read the warnings contained in this booklet carefully as they give important information regarding safety. Please retain this booklet for any further reference that may be necessary.

 

CONTENTS

 

Important Safety Information

6

I. Specifications

7

A. Icemaker

7

1a.

KM-901MAH (air-cooled) Auxiliary Code T-0, U-0

7

1b.

KM-901MAH (air-cooled) Auxiliary Code U-1 and Later

8

2a.

KM-901MWH (water-cooled) Auxiliary Code T-0, U-0

9

2b.

KM-901MWH (water-cooled) Auxiliary Code U-1 and Later

10

3a.

KM-901MRH (remote air-cooled) Auxiliary Code T-0, U-0

11

3b.

KM-901MRH (remote air-cooled) Auxiliary Code U-1 and Later

12

4a.

KM-901MRH3 (remote air-cooled) Auxiliary Code T-0, U-0

13

4b.

KM-901MRH (remote air-cooled) Auxiliary Code U-1 and Later

14

B. Condenser Unit

15

1. URC-9F

15

II. General Information

17

A. Construction

17

1. KM-901MAH (air-cooled)

17

2. KM-901MWH (water-cooled)

18

3. KM-901MRH/3 (remote air-cooled)

19

B. Sequence of Operation

20

1. Sequence Cycles and Shutdown

20

 

a) "E" Control Board: Auxiliary Code T-0, U-0

20

 

b) "G" Control Board: Auxiliary Code U-1 and Later

21

2. Sequence Flow Chart

24

 

a) "E" Control Board: Auxiliary Code T-0, U-0

24

 

b) "G" Control Board: Auxiliary Code U-1 and Later

25

C. Control Board

26

1. Control Board Layout

27

2. Features

29

 

a) Maximum Water Supply Period - 6 minutes

29

 

b) Harvest Backup Timer and Freeze Timer

29

 

c) High Temperature Safety

29

 

d) Low Water Safety

29

 

e) High Voltage and Low Voltage Cut-outs

29

 

f) LED Lights and Audible Alarm Safeties

30

Image 3
Contents KM-901MAH KM-901MWH Hoshizaki AMERICA, INC Contents Page Page Unit Important Safety InformationSerious injury Indicates important information about the use and care1a. KM-901MAH air-cooled Auxiliary Code T-0, U-0 Specifications Icemaker1b. KM-901MAH air-cooled Auxiliary Code U-1 and Later Water Cooled Condenser 2a. KM-901MWH water-cooled Auxiliary Code T-0, U-02b. KM-901MWH water-cooled Auxiliary Code U-1 and Later 3a. KM-901MRH remote air-cooled Auxiliary Code T-0, U-0 3b. KM-901MRH remote air-cooled Auxiliary Code U-1 and Later 4a. KM-901MRH3 remote air-cooled Auxiliary Code T-0, U-0 4b. KM-901MRH remote air-cooled Auxiliary Code U-1 and Later Condenser Unit Model URC-9F SpecificationsKM-901MAH air-cooled II. General Information ConstructionKM-901MWH water-cooled KM-901MRH/3 remote air-cooled Sequence of Operation Sequence Cycles and ShutdownControl Board Auxiliary Code T-0, U-0 Control Board Auxiliary Code U-1 and Later ShutdownOFF Cycle at Shutdown Mechanical Bin Control Activation Bin Full Control Board Sequence Flow ChartSequence Flow Chart CycleFill Cycle Control Board Auxiliary Code U-1Later Minute Harvest Cycle Freeze Cycle Pump-Out CycleControl Board Control Board Control Board LayoutPart Number 2A3792-01 Maximum Water Supply Period 6 minutes Harvest Backup Timer and Freeze TimerHigh Temperature Safety Low Water SafetyEnergized Time LEDs are On Components Min Max Avg LED Lights and Audible Alarm SafetiesNo. of Beeps Type of Alarm Every 3 sec Sequence StepControl Board Auxiliary Code U-1 and Later S4 Dip Switch S4 Dip Switch No Controls and AdjustmentsDefault Dip Switch Settings Harvest Timer S4 dip switch 1Pump-Out Timer S4 dip switch 3 Pump-Out Frequency Control S4 dip switch 5S4 Dip Switch Setting Time seconds Inlet Control Board S4 Dip Switch Setting Pump Motor Time seconds Bin Control Selector/Harvest Pump Timer S4 dip switchFactory Use S4 dip switch Control Board S4 Dip Switch Setting Bin ControlS4 Dip Switch Setting Time Minutes Freeze Timer S4 dip switch 9Float Switch Control S5 dip switch 1 G Control Board Refill Counter S5 dip switch 2 through 5 G Control BoardThermistor Float SwitchControl Switch Bin ControlWater Pump Switch Discharge Line Wiring Diagrams ModelCooled-AirWater-Cooled Model PressureHigh* SwitchKM-901MAH air-cooled and KM-901MWH water-cooled PressureSwitch KM-901MRH remote air-cooledHigh KM-901MRH3 remote air-cooled Cooled-AirModel High* Pressure Switch Cooled-WaterModelHigh Pressure Switch SwitchPressure Performance Data 1570 912835 1480KM-901MRH remote air-cooled KM-901MRH3 remote air-cooled Diagnostic Procedure IV. Service DiagnosisPage OFF Shutdown Thermostatic Bin Control Auxiliary Code T-0, U-0 Control Board CheckControl Correct LED Board Lighting Sequence Bin Control CheckMechanical Bin Control Check Mechanical Bin Control Cleaning Float Switch Check Float Switch Check and CleaningFloat Switch Cleaning Thermistor Check Diagnostic Charts Problem Possible Cause RemedyNo Ice Production Problem Possible Cause Remedy Problem Possible Cause Remedy Evaporator is Frozen Up Problem Possible Cause Remedy Low Ice Production Abnormal Ice Other Removal and Replacement of Components Service for Refrigerant LinesRefrigerant Recovery Evacuation and Recharge R-404A BrazingRemoval and Replacement of Compressor Removal and Replacement of Expansion Valve Page Removal and Replacement of Evaporator Removal and Replacement of Air-Cooled Condenser Removal and Replacement of Water-Cooled Condenser Removal and Replacement of Remote Air-Cooled Condenser Page Adjustment of Water Regulating Valve water-cooled model Removal and Replacement of Thermistor Removal and Replacement of Inlet Water Valve Removal and Replacement of Pump Motor Removal and Replacement of Control Board Cleaning and Sanitizing Instructions VI. Cleaning and MaintenanceCleaning Procedure Sanitizing Procedure Following Cleaning Procedure Preparing the Icemaker for Long Storage MaintenanceDrain the water tank