Hoshizaki KM-901MAH, KM-901MWH, KM-901MRH/3 service manual

Page 4

3. Controls and Adjustments

32

a) Default Dip Switch Settings

32

b) Harvest Timer (S4 dip switch 1 & 2)

32

c) Pump-Out Timer (S4 dip switch 3 & 4)

33

d) Pump-Out Frequency Control (S4 dip switch 5 & 6)

33

e) Bin Control Selector/Harvest Pump Timer (S4 dip switch 7)

34

f) Factory Use (S4 dip switch 8)

34

g) Freeze Timer (S4 dip switch 9 & 10)

35

h) Float Switch Control (S5 dip switch 1): "G" Control Board

35

i) Refill Counter (S5 dip switch 2 through 5): "G" Control Board

35

D. Bin Control

36

1. Thermostatic Bin Control: Auxiliary Code T-0, U-0

36

2. Mechanical Bin Control: Auxiliary Code U-1 and Later

36

E. Float Switch

36

F. Thermistor

36

G. Control Switch

36

III. Technical Information

37

A. Water Circuit and Refrigeration Circuit

37

1. KM-901MAH (air-cooled)

37

2. KM-901MWH (water-cooled)

38

3. KM-901MRH/3 (remote air-cooled)

39

B. Wiring Diagrams

40

1. Thermostatic Bin Control: Auxiliary Code T-0, U-0

40

a) KM-901MAH (air-cooled) and KM-901MWH (water-cooled)

40

b) KM-901MRH (remote air-cooled)

41

c) KM-901MRH3 (remote air-cooled)

42

2. Mechanical Bin Control: Auxiliary Code U-1 and Later

43

a) KM-901MAH (air-cooled) and KM-901MWH (water-cooled)

43

b) KM-901MRH (remote air-cooled)

44

c) KM-901MRH3 (remote air-cooled)

45

C. Performance Data

46

1. KM-901MAH (air-cooled)

46

2. KM-901MWH (water-cooled)

47

3. KM-901MRH (remote air-cooled)

48

4. KM-901MRH3 (remote air-cooled)

49

IV. Service Diagnosis

50

A. Diagnostic Procedure

50

B. Control Board Check

53

C. Bin Control Check

54

1. Thermostatic Bin Control Check: Auxiliary Code T-0, U-0

54

2. Mechanical Bin Control Check and Cleaning: Auxiliary Code U-1 and Later

55

a) Mechanical Bin Control Check

55

b) Mechanical Bin Control Cleaning

56

D. Float Switch Check and Cleaning

57

1. Float Switch Check

57

2. Float Switch Cleaning

58

E. Thermistor Check

59

F. Diagnostic Charts

60

Image 4
Contents KM-901MAH KM-901MWH Hoshizaki AMERICA, INC Contents Page Page Important Safety Information Serious injuryIndicates important information about the use and care UnitSpecifications Icemaker 1a. KM-901MAH air-cooled Auxiliary Code T-0, U-01b. KM-901MAH air-cooled Auxiliary Code U-1 and Later 2a. KM-901MWH water-cooled Auxiliary Code T-0, U-0 Water Cooled Condenser2b. KM-901MWH water-cooled Auxiliary Code U-1 and Later 3a. KM-901MRH remote air-cooled Auxiliary Code T-0, U-0 3b. KM-901MRH remote air-cooled Auxiliary Code U-1 and Later 4a. KM-901MRH3 remote air-cooled Auxiliary Code T-0, U-0 4b. KM-901MRH remote air-cooled Auxiliary Code U-1 and Later Condenser Unit Specifications Model URC-9FII. General Information Construction KM-901MAH air-cooledKM-901MWH water-cooled KM-901MRH/3 remote air-cooled Sequence Cycles and Shutdown Sequence of OperationControl Board Auxiliary Code T-0, U-0 Shutdown Control Board Auxiliary Code U-1 and LaterOFF Cycle at Shutdown Mechanical Bin Control Activation Control Board Sequence Flow Chart Sequence Flow ChartCycle Bin FullControl Board Auxiliary Code U-1 LaterMinute Harvest Cycle Freeze Cycle Pump-Out Cycle Fill CycleControl Board Control Board Layout Control BoardPart Number 2A3792-01 Harvest Backup Timer and Freeze Timer High Temperature SafetyLow Water Safety Maximum Water Supply Period 6 minutesLED Lights and Audible Alarm Safeties No. of Beeps Type of Alarm Every 3 secSequence Step Energized Time LEDs are On Components Min Max AvgControl Board Auxiliary Code U-1 and Later Controls and Adjustments Default Dip Switch SettingsHarvest Timer S4 dip switch 1 S4 Dip Switch S4 Dip Switch NoPump-Out Frequency Control S4 dip switch 5 Pump-Out Timer S4 dip switch 3S4 Dip Switch Setting Time seconds Inlet Bin Control Selector/Harvest Pump Timer S4 dip switch Factory Use S4 dip switchControl Board S4 Dip Switch Setting Bin Control Control Board S4 Dip Switch Setting Pump Motor Time secondsFreeze Timer S4 dip switch 9 Float Switch Control S5 dip switch 1 G Control BoardRefill Counter S5 dip switch 2 through 5 G Control Board S4 Dip Switch Setting Time MinutesFloat Switch Control SwitchBin Control ThermistorWater Pump Switch Discharge Line ModelCooled-AirWater-Cooled Model PressureHigh* Switch Wiring DiagramsKM-901MAH air-cooled and KM-901MWH water-cooled KM-901MRH remote air-cooled PressureSwitchHigh KM-901MRH3 remote air-cooled Switch Cooled-WaterModel Cooled-AirModel High* PressureHigh Pressure Switch SwitchPressure Performance Data 912 8351480 1570KM-901MRH remote air-cooled KM-901MRH3 remote air-cooled IV. Service Diagnosis Diagnostic ProcedurePage OFF Control Board Check Shutdown Thermostatic Bin Control Auxiliary Code T-0, U-0Bin Control Check Control Correct LED Board Lighting SequenceMechanical Bin Control Check Mechanical Bin Control Cleaning Float Switch Check and Cleaning Float Switch CheckFloat Switch Cleaning Thermistor Check Problem Possible Cause Remedy Diagnostic ChartsNo Ice Production Problem Possible Cause Remedy Problem Possible Cause Remedy Evaporator is Frozen Up Problem Possible Cause Remedy Low Ice Production Abnormal Ice Other Service for Refrigerant Lines Removal and Replacement of ComponentsRefrigerant Recovery Brazing Evacuation and Recharge R-404ARemoval and Replacement of Compressor Removal and Replacement of Expansion Valve Page Removal and Replacement of Evaporator Removal and Replacement of Air-Cooled Condenser Removal and Replacement of Water-Cooled Condenser Removal and Replacement of Remote Air-Cooled Condenser Page Adjustment of Water Regulating Valve water-cooled model Removal and Replacement of Thermistor Removal and Replacement of Inlet Water Valve Removal and Replacement of Pump Motor Removal and Replacement of Control Board VI. Cleaning and Maintenance Cleaning and Sanitizing InstructionsCleaning Procedure Sanitizing Procedure Following Cleaning Procedure Maintenance Preparing the Icemaker for Long StorageDrain the water tank