3. KM-901MRH (remote air-cooled)
APPROXIMATE ICE | AMBIENT TEMP. |
|
| WATER TEMP. (ºF/ºC) |
|
| ||||||
PRODUCTION PER 24 HR. | (ºF/ºC) |
| 50/10 |
|
| 70/21 |
|
| 90/32 | |||
|
|
|
| 70/21 | 889 | 403 |
| 859 | 389 |
| 803 | 364 |
|
|
|
| 80/27 | 866 | 393 |
| 818 | 371 |
| 755 | 343 |
|
|
|
| 90/32 | 859 | 389 |
| 785 | 356 |
| 724 | 328 |
lbs./day |
| kg./day | 100/38 | 843 | 382 |
| 771 | 350 |
| 668 | 303 | |
|
|
|
|
|
|
|
|
|
|
|
| |
APPROXIMATE ELECTRIC | 70/21 |
| 1590 |
|
| 1643 |
|
| 1664 | |||
CONSUMPTION | 80/27 |
| 1630 |
|
| 1712 |
|
| 1705 | |||
|
|
|
| 90/32 |
| 1643 |
|
| 1770 |
|
| 1775 |
watts |
|
|
| 100/38 |
| 1630 |
|
| 1771 |
|
| 1780 |
APPROXIMATE WATER | 70/21 | 246 | 0.93 |
| 219 | 0.83 |
| 194 | 0.74 | |||
CONSUMPTION PER 24 HR. | 80/27 | 225 | 0.85 |
| 182 | 0.69 |
| 165 | 0.63 | |||
|
|
|
| 90/32 | 219 | 0.83 |
| 152 | 0.57 |
| 131 | 0.50 |
gal./day |
| m3/day | 100/38 | 182 | 0.69 |
| 147 | 0.56 |
| 112 | 0.42 | |
FREEZING CYCLE TIME | 70/21 |
| 18 |
|
| 20 |
|
| 21 | |||
|
|
|
| 80/27 |
| 19 |
|
| 21 |
|
| 23 |
|
|
|
| 90/32 |
| 20 |
|
| 22 |
|
| 24 |
min. |
|
|
| 100/38 |
| 20 |
|
| 23 |
|
| 26 |
HARVEST CYCLE TIME | 70/21 |
| 4.3 |
|
| 3.9 |
|
| 3.6 | |||
|
|
|
| 80/27 |
| 4.0 |
|
| 3.4 |
|
| 3.2 |
|
|
|
| 90/32 |
| 3.9 |
|
| 2.9 |
|
| 2.7 |
min. |
|
|
| 100/38 |
| 3.4 |
|
| 2.8 |
|
| 2.4 |
HEAD PRESSURE | 70/21 | 208 | 14.6 |
| 229 | 16.1 |
| 252 | 17.7 | |||
|
|
|
| 80/27 | 224 | 15.7 |
| 256 | 18.0 |
| 277 | 19.5 |
|
|
|
| 90/32 | 229 | 16.1 |
| 279 | 19.6 |
| 301 | 21.2 |
PSIG | kg/cm2G | 100/38 | 232 | 16.3 |
| 284 | 20.0 |
| 322 | 22.6 | ||
SUCTION PRESSURE | 70/21 | 35 | 2.5 |
| 37 | 2.6 |
| 41 | 2.9 | |||
|
|
|
| 80/27 | 37 | 2.6 |
| 40 | 2.8 |
| 45 | 3.1 |
|
|
|
| 90/32 | 37 | 2.6 |
| 43 | 3.0 |
| 47 | 3.3 |
PSIG | kg/cm2G | 100/38 | 38 | 2.7 |
| 44 | 3.1 |
| 51 | 3.6 |
TOTAL HEAT OF REJECTION FROM CONDENSER | 14,000 | BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)] |
TOTAL HEAT OF REJECTION FROM COMPRESSOR | 2,200 | BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)] |
CONDENSER VOLUME | 121 | CU. IN |
Note:
1.Pressure data is recorded at 5 minutes into freeze cycle. The data not in bold should be used for reference only.
2.We reserve the right to make changes in specifications and design without prior notice.
48