Hoshizaki KM-901MWH, KM-901MAH, KM-901MRH/3 service manual KM-901MRH remote air-cooled

Page 48

3. KM-901MRH (remote air-cooled)

APPROXIMATE ICE

AMBIENT TEMP.

 

 

WATER TEMP. (ºF/ºC)

 

 

PRODUCTION PER 24 HR.

(ºF/ºC)

 

50/10

 

 

70/21

 

 

90/32

 

 

 

 

70/21

889

403

 

859

389

 

803

364

 

 

 

 

80/27

866

393

 

818

371

 

755

343

 

 

 

 

90/32

859

389

 

785

356

 

724

328

lbs./day

 

kg./day

100/38

843

382

 

771

350

 

668

303

 

 

 

 

 

 

 

 

 

 

 

 

APPROXIMATE ELECTRIC

70/21

 

1590

 

 

1643

 

 

1664

CONSUMPTION

80/27

 

1630

 

 

1712

 

 

1705

 

 

 

 

90/32

 

1643

 

 

1770

 

 

1775

watts

 

 

 

100/38

 

1630

 

 

1771

 

 

1780

APPROXIMATE WATER

70/21

246

0.93

 

219

0.83

 

194

0.74

CONSUMPTION PER 24 HR.

80/27

225

0.85

 

182

0.69

 

165

0.63

 

 

 

 

90/32

219

0.83

 

152

0.57

 

131

0.50

gal./day

 

m3/day

100/38

182

0.69

 

147

0.56

 

112

0.42

FREEZING CYCLE TIME

70/21

 

18

 

 

20

 

 

21

 

 

 

 

80/27

 

19

 

 

21

 

 

23

 

 

 

 

90/32

 

20

 

 

22

 

 

24

min.

 

 

 

100/38

 

20

 

 

23

 

 

26

HARVEST CYCLE TIME

70/21

 

4.3

 

 

3.9

 

 

3.6

 

 

 

 

80/27

 

4.0

 

 

3.4

 

 

3.2

 

 

 

 

90/32

 

3.9

 

 

2.9

 

 

2.7

min.

 

 

 

100/38

 

3.4

 

 

2.8

 

 

2.4

HEAD PRESSURE

70/21

208

14.6

 

229

16.1

 

252

17.7

 

 

 

 

80/27

224

15.7

 

256

18.0

 

277

19.5

 

 

 

 

90/32

229

16.1

 

279

19.6

 

301

21.2

PSIG

kg/cm2G

100/38

232

16.3

 

284

20.0

 

322

22.6

SUCTION PRESSURE

70/21

35

2.5

 

37

2.6

 

41

2.9

 

 

 

 

80/27

37

2.6

 

40

2.8

 

45

3.1

 

 

 

 

90/32

37

2.6

 

43

3.0

 

47

3.3

PSIG

kg/cm2G

100/38

38

2.7

 

44

3.1

 

51

3.6

TOTAL HEAT OF REJECTION FROM CONDENSER

14,000

BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]

TOTAL HEAT OF REJECTION FROM COMPRESSOR

2,200

BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]

CONDENSER VOLUME

121

CU. IN (URC-9F)

Note:

1.Pressure data is recorded at 5 minutes into freeze cycle. The data not in bold should be used for reference only.

2.We reserve the right to make changes in specifications and design without prior notice.

48

Image 48
Contents KM-901MAH KM-901MWH Hoshizaki AMERICA, INC Contents Page Page Important Safety Information Serious injuryIndicates important information about the use and care UnitSpecifications Icemaker 1a. KM-901MAH air-cooled Auxiliary Code T-0, U-01b. KM-901MAH air-cooled Auxiliary Code U-1 and Later 2a. KM-901MWH water-cooled Auxiliary Code T-0, U-0 Water Cooled Condenser2b. KM-901MWH water-cooled Auxiliary Code U-1 and Later 3a. KM-901MRH remote air-cooled Auxiliary Code T-0, U-0 3b. KM-901MRH remote air-cooled Auxiliary Code U-1 and Later 4a. KM-901MRH3 remote air-cooled Auxiliary Code T-0, U-0 4b. KM-901MRH remote air-cooled Auxiliary Code U-1 and Later Condenser Unit Specifications Model URC-9FII. General Information Construction KM-901MAH air-cooledKM-901MWH water-cooled KM-901MRH/3 remote air-cooled Sequence of Operation Sequence Cycles and ShutdownControl Board Auxiliary Code T-0, U-0 Shutdown Control Board Auxiliary Code U-1 and LaterOFF Cycle at Shutdown Mechanical Bin Control Activation Control Board Sequence Flow Chart Sequence Flow ChartCycle Bin FullControl Board Auxiliary Code U-1 LaterMinute Harvest Cycle Freeze Cycle Pump-Out Cycle Fill CycleControl Board Control Board Layout Control BoardPart Number 2A3792-01 Harvest Backup Timer and Freeze Timer High Temperature SafetyLow Water Safety Maximum Water Supply Period 6 minutesLED Lights and Audible Alarm Safeties No. of Beeps Type of Alarm Every 3 secSequence Step Energized Time LEDs are On Components Min Max AvgControl Board Auxiliary Code U-1 and Later Controls and Adjustments Default Dip Switch SettingsHarvest Timer S4 dip switch 1 S4 Dip Switch S4 Dip Switch NoPump-Out Timer S4 dip switch 3 Pump-Out Frequency Control S4 dip switch 5S4 Dip Switch Setting Time seconds Inlet Bin Control Selector/Harvest Pump Timer S4 dip switch Factory Use S4 dip switchControl Board S4 Dip Switch Setting Bin Control Control Board S4 Dip Switch Setting Pump Motor Time secondsFreeze Timer S4 dip switch 9 Float Switch Control S5 dip switch 1 G Control BoardRefill Counter S5 dip switch 2 through 5 G Control Board S4 Dip Switch Setting Time MinutesFloat Switch Control SwitchBin Control ThermistorWater Pump Switch Discharge Line Wiring Diagrams ModelCooled-AirWater-Cooled Model PressureHigh* SwitchKM-901MAH air-cooled and KM-901MWH water-cooled PressureSwitch KM-901MRH remote air-cooledHigh KM-901MRH3 remote air-cooled Switch Cooled-WaterModel Cooled-AirModel High* PressureHigh Pressure Switch SwitchPressure Performance Data 912 8351480 1570KM-901MRH remote air-cooled KM-901MRH3 remote air-cooled IV. Service Diagnosis Diagnostic ProcedurePage OFF Control Board Check Shutdown Thermostatic Bin Control Auxiliary Code T-0, U-0Bin Control Check Control Correct LED Board Lighting SequenceMechanical Bin Control Check Mechanical Bin Control Cleaning Float Switch Check and Cleaning Float Switch CheckFloat Switch Cleaning Thermistor Check Diagnostic Charts Problem Possible Cause RemedyNo Ice Production Problem Possible Cause Remedy Problem Possible Cause Remedy Evaporator is Frozen Up Problem Possible Cause Remedy Low Ice Production Abnormal Ice Other Removal and Replacement of Components Service for Refrigerant LinesRefrigerant Recovery Brazing Evacuation and Recharge R-404ARemoval and Replacement of Compressor Removal and Replacement of Expansion Valve Page Removal and Replacement of Evaporator Removal and Replacement of Air-Cooled Condenser Removal and Replacement of Water-Cooled Condenser Removal and Replacement of Remote Air-Cooled Condenser Page Adjustment of Water Regulating Valve water-cooled model Removal and Replacement of Thermistor Removal and Replacement of Inlet Water Valve Removal and Replacement of Pump Motor Removal and Replacement of Control Board VI. Cleaning and Maintenance Cleaning and Sanitizing InstructionsCleaning Procedure Sanitizing Procedure Following Cleaning Procedure Maintenance Preparing the Icemaker for Long StorageDrain the water tank