Problem | Possible Cause |
| Remedy | |
|
|
|
| |
[3] Compressor will | a) Magnetic Contactor | 1. Bad contacts. | 1. Check for continuity and | |
not start or stops |
|
| replace. | |
operating. |
| 2. Coil winding open. | 2. Replace. | |
|
| |||
|
|
|
| |
| b) Start Capacitor or Run | 1. Defective. | 1. Replace. | |
| Capacitor |
|
| |
|
|
|
| |
| c) Internal Overload | 1. Loose terminal. | 1. Tighten or replace. | |
| Protector Open (check |
|
| |
| 2. Voltage. | 2. Check and correct. | ||
| 1 through 3 to the right | |||
| and d through f below) | 3. Dirty condenser. | 3. Clean. | |
|
|
|
| |
| d) Starter | 1. Bad contacts. | 1. Check and replace. | |
|
| 2. Coil winding open. | 2. Replace. | |
| e) Compressor | 1. Power supply not | 1. Refer to nameplate and | |
|
| within specifications. | correct. | |
|
|
|
| |
|
| 2. Wiring to compressor. | 2. Check for loose connection | |
|
|
| or open, and replace. | |
|
|
|
| |
|
| 3. Defective. | 3. Replace. | |
|
|
|
| |
|
| 4. Protector tripped. | 4. Reduce temperature. | |
| f) Control Board | 1. No power to contactor. | 1. See "IV.B. Control Board | |
|
|
| Check." | |
|
|
|
| |
[4] Water continues to | a) Water Pressure | 1. Too high. | 1. Reduce. | |
be supplied in freeze |
|
|
| |
b) Inlet Water Valve | 1. Diaphragm does not | 1. Check for water leaks with | ||
cycle. |
| close. | icemaker off. | |
|
| |||
|
|
|
| |
| c) Control Board | 1. Defective. | 1. See "IV.B. Control Board | |
|
|
| Check." | |
[5] Pump motor will not | a) Pump Motor | 1. Motor winding open. | 1. Replace. | |
start. |
|
|
| |
| 2. Bearing worn out. | 2. Replace. | ||
|
| |||
|
|
|
| |
|
| 3. Wiring to pump motor. | 3. Check for loose connection | |
|
|
| or open, and replace. | |
|
|
|
| |
|
| 4. Defective capacitor. | 4. Replace. | |
|
| 5. Defective or bound | 5. Replace and clean. | |
|
| impeller. |
| |
|
|
|
| |
|
| 6. Mechanical seal worn | 6. Check and replace. | |
|
| out. |
| |
|
|
|
| |
| b) Control Board | 1. Defective. | 1. See "IV.B. Control Board | |
|
|
| Check." | |
|
|
|
| |
| c) Control Switch | 1. Bad contacts. | 1. Replace. | |
[6] Freeze cycle time is | a) | 1. Leaking by. | 1. Clean or replace. | |
too short. |
|
|
| |
b) Float Switch | 1. Dirty or erratic | 1. Clean or replace. See "IV. | ||
| ||||
|
| operation. | D. Float Switch Check and | |
|
|
| Cleaning." | |
|
|
|
| |
| c) Control Board | 1. Defective. | 1. See "IV.B. Control Board | |
|
|
| Check." | |
|
|
|
| |
| d) Water System | 1. Water leaks. | 1. Check connections for | |
|
|
| water leaks and repair. |
62