Hoshizaki KM-901MAH, KM-901MRH/3 2b. KM-901MWH water-cooled Auxiliary Code U-1 and Later

Page 10

2b. KM-901MWH (water-cooled) Auxiliary Code U-1 and Later

AC SUPPLY VOLTAGE

208-230/60/1 (3 wire with netrual for 115V)

 

AMPERAGE

8.7A ( 5 Min. Freeze AT 104°F / WT 80°F)

 

MINIMUM CIRCUIT AMPACITY

15 A

 

 

 

MAXIMUM FUSE SIZE

15 A

 

 

 

APPROXIMATE ICE PRODUCTION

Ambient

WATER TEMP. (°F)

PER 24 HR.

Temp.(°F)

50

70

90

lbs./day ( kg/day )

70

*912 (414)

889 (403)

849 (385)

Reference without *marks

80

895 (406)

860 (390)

815 (370)

 

90

889 (403)

*835 (379)

791 (359)

SHAPE OF ICE

100

878 (398)

825 (374)

751 (341)

Crescent Cube

 

 

 

ICE PRODUCTION PER CYCLE

13.4 lbs. (6.1 kg) 720pcs.

 

 

APPROXIMATE STORAGE CAPACITY

N/A

 

 

 

ELECTRIC & WATER CONSUMPTION

90/70°F

 

70/50°F

 

ELECTRIC W (kWH/100 lbs.)

1570(4.5)

 

1480(3.9)

 

WATER gal./24HR (gal./100 lbs.)

182(21.8)

 

245(26.9)

 

WATER COOLED CONDENSER

1162(139)

 

631(69)

 

gal./24HR (gal./100 lbs.)

 

 

 

 

EXTERIOR DIMENSIONS (WxDxH)

30" x 27-3/8" x 37-7/16" (762 x 695 x 950 mm)

 

EXTERIOR FINISH

Stainless Steel, Galvanized Steel (Rear)

 

WEIGHT

Net 189 lbs. (86 kg), Shipping

249 lbs. (113 kg)

CONNECTIONS - ELECTRIC

Permanent - Connection

 

 

- WATER SUPPLY

Inlet

1/2" FPT

Cond. Inlet

1/2" FPT

- DRAIN

Outlet

3/4" FPT

Cond. Outlet

3/8" FPT

 

 

3/8" OD Tube

 

 

CUBE CONTROL SYSTEM

Float Switch

 

 

 

HARVESTING CONTROL SYSTEM

Hot Gas and Water, Thermistor and Timer

 

ICE MAKING WATER CONTROL

Timer Controlled. Overflow Pipe

 

COOLING WATER CONTROL

Pressure Regulator

 

 

BIN CONTROL SYSTEM

Mechanical Switch

 

 

COMPRESSOR

Hermetic, Model CS12K6E-PFV-237

 

CONDENSER

Water-cooled, Tube in tube type

 

EVAPORATOR

Vertical type, Stainless Steel and Copper

 

REFRIGERANT CONTROL

Thermostatic Expansion Valve

 

 

REFRIGERANT CHARGE

R404A, 1 lb. 15.4 oz. (890g)

 

 

DESIGN PRESSURE

High 427PSIG, Low 230PSIG

 

 

P.C. BOARD CIRCUIT PROTECTION

High Voltage Cut-out ( Internal )

 

COMPRESSOR PROTECTION

Auto-reset Overload Protector ( Internal )

 

REFRIGERANT CIRCUIT PROTECTION

Auto-reset High Pressure Control Switch

 

LOW WATER PROTECTION

Float Switch

 

 

 

ACCESSORIES -SUPPLIED

N/A

 

 

 

-REQUIRED

Ice Storage Bin

 

 

 

OPERATING CONDITIONS

VOLTAGE RANGE

 

187 - 253 V

 

AMBIENT TEMP.

 

45 -100° F

 

WATER SUPPLY TEMP.

 

45 - 90° F

 

WATER SUPPLY PRESSURE

 

10 - 113 PSIG

Note: We reserve the right to make changes in specifications and design without prior notice.

10

Image 10
Contents KM-901MAH KM-901MWH Hoshizaki AMERICA, INC Contents Page Page Indicates important information about the use and care Important Safety InformationSerious injury UnitSpecifications Icemaker 1a. KM-901MAH air-cooled Auxiliary Code T-0, U-01b. KM-901MAH air-cooled Auxiliary Code U-1 and Later 2a. KM-901MWH water-cooled Auxiliary Code T-0, U-0 Water Cooled Condenser2b. KM-901MWH water-cooled Auxiliary Code U-1 and Later 3a. KM-901MRH remote air-cooled Auxiliary Code T-0, U-0 3b. KM-901MRH remote air-cooled Auxiliary Code U-1 and Later 4a. KM-901MRH3 remote air-cooled Auxiliary Code T-0, U-0 4b. KM-901MRH remote air-cooled Auxiliary Code U-1 and Later Condenser Unit Specifications Model URC-9FII. General Information Construction KM-901MAH air-cooledKM-901MWH water-cooled KM-901MRH/3 remote air-cooled Sequence Cycles and Shutdown Sequence of OperationControl Board Auxiliary Code T-0, U-0 Shutdown Control Board Auxiliary Code U-1 and LaterOFF Cycle at Shutdown Mechanical Bin Control Activation Cycle Control Board Sequence Flow ChartSequence Flow Chart Bin FullMinute Harvest Cycle Freeze Cycle Pump-Out Cycle Control Board Auxiliary Code U-1Later Fill CycleControl Board Control Board Layout Control BoardPart Number 2A3792-01 Low Water Safety Harvest Backup Timer and Freeze TimerHigh Temperature Safety Maximum Water Supply Period 6 minutesSequence Step LED Lights and Audible Alarm SafetiesNo. of Beeps Type of Alarm Every 3 sec Energized Time LEDs are On Components Min Max AvgControl Board Auxiliary Code U-1 and Later Harvest Timer S4 dip switch 1 Controls and AdjustmentsDefault Dip Switch Settings S4 Dip Switch S4 Dip Switch NoPump-Out Frequency Control S4 dip switch 5 Pump-Out Timer S4 dip switch 3S4 Dip Switch Setting Time seconds Inlet Control Board S4 Dip Switch Setting Bin Control Bin Control Selector/Harvest Pump Timer S4 dip switchFactory Use S4 dip switch Control Board S4 Dip Switch Setting Pump Motor Time secondsRefill Counter S5 dip switch 2 through 5 G Control Board Freeze Timer S4 dip switch 9Float Switch Control S5 dip switch 1 G Control Board S4 Dip Switch Setting Time MinutesBin Control Float SwitchControl Switch ThermistorWater Pump Switch Discharge Line ModelCooled-AirWater-Cooled Model PressureHigh* Switch Wiring DiagramsKM-901MAH air-cooled and KM-901MWH water-cooled KM-901MRH remote air-cooled PressureSwitchHigh KM-901MRH3 remote air-cooled Switch Cooled-WaterModel Cooled-AirModel High* PressureHigh Pressure Switch SwitchPressure Performance Data 1480 912835 1570KM-901MRH remote air-cooled KM-901MRH3 remote air-cooled IV. Service Diagnosis Diagnostic ProcedurePage OFF Control Board Check Shutdown Thermostatic Bin Control Auxiliary Code T-0, U-0Bin Control Check Control Correct LED Board Lighting SequenceMechanical Bin Control Check Mechanical Bin Control Cleaning Float Switch Check and Cleaning Float Switch CheckFloat Switch Cleaning Thermistor Check Problem Possible Cause Remedy Diagnostic ChartsNo Ice Production Problem Possible Cause Remedy Problem Possible Cause Remedy Evaporator is Frozen Up Problem Possible Cause Remedy Low Ice Production Abnormal Ice Other Service for Refrigerant Lines Removal and Replacement of ComponentsRefrigerant Recovery Brazing Evacuation and Recharge R-404ARemoval and Replacement of Compressor Removal and Replacement of Expansion Valve Page Removal and Replacement of Evaporator Removal and Replacement of Air-Cooled Condenser Removal and Replacement of Water-Cooled Condenser Removal and Replacement of Remote Air-Cooled Condenser Page Adjustment of Water Regulating Valve water-cooled model Removal and Replacement of Thermistor Removal and Replacement of Inlet Water Valve Removal and Replacement of Pump Motor Removal and Replacement of Control Board VI. Cleaning and Maintenance Cleaning and Sanitizing InstructionsCleaning Procedure Sanitizing Procedure Following Cleaning Procedure Maintenance Preparing the Icemaker for Long StorageDrain the water tank