Hoshizaki KM-901MWH, KM-901MAH 3b. KM-901MRH remote air-cooled Auxiliary Code U-1 and Later

Page 12

3b. KM-901MRH (remote air-cooled) Auxiliary Code U-1 and Later

AC SUPPLY VOLTAGE

208-230/60/1 (3 wire with netrual for 115V)

 

AMPERAGE

11.6A ( 5 Min. Freeze AT 104°F / WT 80°F)

 

MINIMUM CIRCUIT AMPACITY

20 A

 

 

 

 

 

MAXIMUM FUSE SIZE

20 A

 

 

 

 

 

APPROXIMATE ICE PRODUCTION

Ambient

WATER TEMP. (°F)

 

PER 24 HR.

Temp.(°F)

50

 

70

 

90

lbs./day ( kg/day )

70

*889 (403)

 

859 (389)

 

803 (364)

Reference without *marks

80

866 (393)

 

818 (371)

 

755 (343)

 

90

859 (389)

 

*785 (356)

 

724 (328)

SHAPE OF ICE

100

843 (382)

 

771 (350)

 

668 (303)

Crescent Cube

 

 

 

 

 

ICE PRODUCTION PER CYCLE

13.5 lbs. (6.1 kg) 720pcs.

 

 

 

APPROXIMATE STORAGE CAPACITY

N/A

 

 

 

 

 

ELECTRIC & WATER CONSUMPTION

90/70°F

 

 

70/50°F

 

ELECTRIC W (kWH/100 lbs.)

1770(5.4)

 

 

1590(4.3)

 

 

WATER gal./24HR (gal./100 lbs.)

152(19.3)

 

 

246(27.7)

 

 

EXTERIOR DIMENSIONS (WxDxH)

30" x 27-3/8" x 37-7/16" (762 x 695 x 950 mm)

 

EXTERIOR FINISH

Stainless Steel, Galvanized Steel (Rear)

 

WEIGHT

Net 189 lbs. (86 kg), Shipping

249 lbs. (113 kg)

 

CONNECTIONS - ELECTRIC

Permanent - Connection

 

 

 

- WATER SUPPLY

Inlet

1/2" FPT

 

 

 

- DRAIN

Outlet

3/4" FPT

 

 

 

 

 

3/8" OD Tube

 

 

 

CUBE CONTROL SYSTEM

Float Switch

 

 

 

 

 

HARVESTING CONTROL SYSTEM

Hot Gas and Water, Thermistor and Timer

 

ICE MAKING WATER CONTROL

Timer Controlled. Overflow Pipe

 

COOLING WATER CONTROL

N/A

 

 

 

 

 

BIN CONTROL SYSTEM

Mechanical Switch

 

 

 

COMPRESSOR

Hermetic, Model CS12K6E-PFV-279

 

CONDENSER

Air-Cooled Remote, Condenser Unit URC-9F

 

EVAPORATOR

Vertical type, Stainless Steel and Copper

 

REFRIGERANT CONTROL

Thermostatic Expansion Valve

 

 

 

 

Condensing Pressure Regulator on URC-9F

 

REFRIGERANT CHARGE

R404A, 9 lbs. 4 oz. (4200g)

 

 

 

 

(Icemaker 5 lbs. 5 oz. Cond. Unit 3 lbs. 15 oz.)

 

DESIGN PRESSURE

High 467PSIG, Low 230PSIG

 

 

 

P.C. BOARD CIRCUIT PROTECTION

High Voltage Cut-out ( Internal )

 

 

 

COMPRESSOR PROTECTION

Auto-reset Overload Protector ( Internal )

 

REFRIGERANT CIRCUIT PROTECTION

Auto-reset High Pressure Control Switch

 

LOW WATER PROTECTION

Float Switch

 

 

 

 

 

ACCESSORIES -SUPPLIED

N/A

 

 

 

 

 

-REQUIRED

Ice Storage Bin, Remote Condenser Unit

 

OPERATING CONDITIONS

VOLTAGE RANGE

 

 

187 - 253 V

 

AMBIENT TEMP.

 

 

45 -100° F

 

WATER SUPPLY TEMP.

 

 

45 - 90° F

 

WATER SUPPLY PRESSURE

 

10 - 113 PSIG

Note: We reserve the right to make changes in specifications and design without prior notice.

12

Image 12
Contents KM-901MAH KM-901MWH Hoshizaki AMERICA, INC Contents Page Page Important Safety Information Serious injuryIndicates important information about the use and care UnitSpecifications Icemaker 1a. KM-901MAH air-cooled Auxiliary Code T-0, U-01b. KM-901MAH air-cooled Auxiliary Code U-1 and Later 2a. KM-901MWH water-cooled Auxiliary Code T-0, U-0 Water Cooled Condenser2b. KM-901MWH water-cooled Auxiliary Code U-1 and Later 3a. KM-901MRH remote air-cooled Auxiliary Code T-0, U-0 3b. KM-901MRH remote air-cooled Auxiliary Code U-1 and Later 4a. KM-901MRH3 remote air-cooled Auxiliary Code T-0, U-0 4b. KM-901MRH remote air-cooled Auxiliary Code U-1 and Later Condenser Unit Specifications Model URC-9FII. General Information Construction KM-901MAH air-cooledKM-901MWH water-cooled KM-901MRH/3 remote air-cooled Sequence of Operation Sequence Cycles and ShutdownControl Board Auxiliary Code T-0, U-0 Shutdown Control Board Auxiliary Code U-1 and LaterOFF Cycle at Shutdown Mechanical Bin Control Activation Control Board Sequence Flow Chart Sequence Flow ChartCycle Bin FullControl Board Auxiliary Code U-1 LaterMinute Harvest Cycle Freeze Cycle Pump-Out Cycle Fill CycleControl Board Control Board Layout Control BoardPart Number 2A3792-01 Harvest Backup Timer and Freeze Timer High Temperature SafetyLow Water Safety Maximum Water Supply Period 6 minutesLED Lights and Audible Alarm Safeties No. of Beeps Type of Alarm Every 3 secSequence Step Energized Time LEDs are On Components Min Max AvgControl Board Auxiliary Code U-1 and Later Controls and Adjustments Default Dip Switch SettingsHarvest Timer S4 dip switch 1 S4 Dip Switch S4 Dip Switch NoPump-Out Timer S4 dip switch 3 Pump-Out Frequency Control S4 dip switch 5S4 Dip Switch Setting Time seconds Inlet Bin Control Selector/Harvest Pump Timer S4 dip switch Factory Use S4 dip switchControl Board S4 Dip Switch Setting Bin Control Control Board S4 Dip Switch Setting Pump Motor Time secondsFreeze Timer S4 dip switch 9 Float Switch Control S5 dip switch 1 G Control BoardRefill Counter S5 dip switch 2 through 5 G Control Board S4 Dip Switch Setting Time MinutesFloat Switch Control SwitchBin Control ThermistorWater Pump Switch Discharge Line Wiring Diagrams ModelCooled-AirWater-Cooled Model PressureHigh* SwitchKM-901MAH air-cooled and KM-901MWH water-cooled PressureSwitch KM-901MRH remote air-cooledHigh KM-901MRH3 remote air-cooled Switch Cooled-WaterModel Cooled-AirModel High* PressureHigh Pressure Switch SwitchPressure Performance Data 912 8351480 1570KM-901MRH remote air-cooled KM-901MRH3 remote air-cooled IV. Service Diagnosis Diagnostic ProcedurePage OFF Control Board Check Shutdown Thermostatic Bin Control Auxiliary Code T-0, U-0Bin Control Check Control Correct LED Board Lighting SequenceMechanical Bin Control Check Mechanical Bin Control Cleaning Float Switch Check and Cleaning Float Switch CheckFloat Switch Cleaning Thermistor Check Diagnostic Charts Problem Possible Cause RemedyNo Ice Production Problem Possible Cause Remedy Problem Possible Cause Remedy Evaporator is Frozen Up Problem Possible Cause Remedy Low Ice Production Abnormal Ice Other Removal and Replacement of Components Service for Refrigerant LinesRefrigerant Recovery Brazing Evacuation and Recharge R-404ARemoval and Replacement of Compressor Removal and Replacement of Expansion Valve Page Removal and Replacement of Evaporator Removal and Replacement of Air-Cooled Condenser Removal and Replacement of Water-Cooled Condenser Removal and Replacement of Remote Air-Cooled Condenser Page Adjustment of Water Regulating Valve water-cooled model Removal and Replacement of Thermistor Removal and Replacement of Inlet Water Valve Removal and Replacement of Pump Motor Removal and Replacement of Control Board VI. Cleaning and Maintenance Cleaning and Sanitizing InstructionsCleaning Procedure Sanitizing Procedure Following Cleaning Procedure Maintenance Preparing the Icemaker for Long StorageDrain the water tank