C. Performance Data
1. KM-901MAH (air-cooled)
APPROXIMATE ICE | AMBIENT TEMP. |
|
|
| WATER TEMP. (ºF/ºC) |
|
| ||||||
PRODUCTION PER 24 HR. | (ºF/ºC) |
| 50/10 |
|
|
| 70/21 |
|
| 90/32 | |||
|
|
|
| 70/21 |
| 874 | 396 |
| 832 | 378 |
| 785 | 356 |
|
|
|
| 80/27 |
| 842 | 382 |
| 778 | 353 |
| 736 | 334 |
|
|
|
| 90/32 |
| 832 | 378 |
| 732 | 332 |
| 687 | 312 |
lbs./day |
| kg./day | 100/38 |
| 826 | 375 |
| 721 | 327 |
| 646 | 293 | |
|
|
|
|
|
|
|
|
|
|
|
|
| |
APPROXIMATE ELECTRIC | 70/21 |
| 1600 |
|
|
| 1632 |
|
| 1658 | |||
CONSUMPTION | 80/27 |
| 1625 |
|
|
| 1675 |
|
| 1691 | |||
|
|
|
| 90/32 |
| 1632 |
|
|
| 1710 |
|
| 1731 |
watts |
|
|
| 100/38 |
| 1631 |
|
|
| 1715 |
|
| 1750 |
APPROXIMATE WATER | 70/21 |
| 240 | 0.91 |
| 212 | 0.80 |
| 187 | 0.71 | |||
CONSUMPTION PER 24 HR. | 80/27 |
| 219 | 0.83 |
| 175 | 0.66 |
| 158 | 0.60 | |||
|
| m3/day | 90/32 |
| 212 | 0.80 |
| 143 | 0.54 |
| 123 | 0.46 | |
gal./day |
| 100/38 |
| 175 | 0.66 |
| 139 | 0.52 |
| 103 | 0.39 | ||
FREEZING CYCLE TIME | 70/21 |
| 19 |
|
|
| 20 |
|
| 22 | |||
|
|
|
| 80/27 |
| 20 |
|
|
| 22 |
|
| 24 |
|
|
|
| 90/32 |
| 20 |
|
|
| 24 |
|
| 26 |
min. |
|
|
| 100/38 |
| 21 |
|
|
| 24 |
|
| 27 |
HARVEST CYCLE TIME | 70/21 |
| 4.3 |
|
|
| 3.9 |
|
| 3.6 | |||
|
|
|
| 80/27 |
| 4.0 |
|
|
| 3.3 |
|
| 3.1 |
|
|
|
| 90/32 |
| 3.9 |
|
|
| 2.8 |
|
| 2.6 |
min. |
|
|
| 100/38 |
| 3.3 |
|
|
| 2.7 |
|
| 2.4 |
HEAD PRESSURE | 70/21 |
| 219 | 15.4 |
| 238 | 16.7 |
| 261 | 18.3 | |||
|
|
|
| 80/27 |
| 234 | 16.4 |
| 263 | 18.5 |
| 284 | 20.0 |
|
|
|
| 90/32 |
| 238 | 16.7 |
| 284 | 20.0 |
| 306 | 21.5 |
PSIG | kg/cm2G | 100/38 |
| 242 | 17.0 |
| 289 | 20.3 |
| 327 | 23.0 | ||
SUCTION PRESSURE | 70/21 |
| 35 | 2.5 |
| 37 | 2.6 |
| 41 | 2.9 | |||
|
|
|
| 80/27 |
| 36 | 2.6 |
| 39 | 2.7 |
| 44 | 3.1 |
|
|
|
| 90/32 |
| 37 | 2.6 |
| 41 | 2.9 |
| 46 | 3.2 |
PSIG | kg/cm2G | 100/38 |
| 38 | 2.7 |
| 42 | 3.0 |
| 50 | 3.5 | ||
TOTAL HEAT OF REJECTION FROM CONDENSER |
| 15,400 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)] |
Note:
1.Pressure data is recorded at 5 minutes into freeze cycle. The data not in bold should be used for reference only.
2.We reserve the right to make changes in specifications and design without prior notice.
46