Hoshizaki KM-901MAH, KM-901MWH, KM-901MRH/3 service manual Performance Data

Page 46

C. Performance Data

1. KM-901MAH (air-cooled)

APPROXIMATE ICE

AMBIENT TEMP.

 

 

 

WATER TEMP. (ºF/ºC)

 

 

PRODUCTION PER 24 HR.

(ºF/ºC)

 

50/10

 

 

 

70/21

 

 

90/32

 

 

 

 

70/21

 

874

396

 

832

378

 

785

356

 

 

 

 

80/27

 

842

382

 

778

353

 

736

334

 

 

 

 

90/32

 

832

378

 

732

332

 

687

312

lbs./day

 

kg./day

100/38

 

826

375

 

721

327

 

646

293

 

 

 

 

 

 

 

 

 

 

 

 

 

APPROXIMATE ELECTRIC

70/21

 

1600

 

 

 

1632

 

 

1658

CONSUMPTION

80/27

 

1625

 

 

 

1675

 

 

1691

 

 

 

 

90/32

 

1632

 

 

 

1710

 

 

1731

watts

 

 

 

100/38

 

1631

 

 

 

1715

 

 

1750

APPROXIMATE WATER

70/21

 

240

0.91

 

212

0.80

 

187

0.71

CONSUMPTION PER 24 HR.

80/27

 

219

0.83

 

175

0.66

 

158

0.60

 

 

m3/day

90/32

 

212

0.80

 

143

0.54

 

123

0.46

gal./day

 

100/38

 

175

0.66

 

139

0.52

 

103

0.39

FREEZING CYCLE TIME

70/21

 

19

 

 

 

20

 

 

22

 

 

 

 

80/27

 

20

 

 

 

22

 

 

24

 

 

 

 

90/32

 

20

 

 

 

24

 

 

26

min.

 

 

 

100/38

 

21

 

 

 

24

 

 

27

HARVEST CYCLE TIME

70/21

 

4.3

 

 

 

3.9

 

 

3.6

 

 

 

 

80/27

 

4.0

 

 

 

3.3

 

 

3.1

 

 

 

 

90/32

 

3.9

 

 

 

2.8

 

 

2.6

min.

 

 

 

100/38

 

3.3

 

 

 

2.7

 

 

2.4

HEAD PRESSURE

70/21

 

219

15.4

 

238

16.7

 

261

18.3

 

 

 

 

80/27

 

234

16.4

 

263

18.5

 

284

20.0

 

 

 

 

90/32

 

238

16.7

 

284

20.0

 

306

21.5

PSIG

kg/cm2G

100/38

 

242

17.0

 

289

20.3

 

327

23.0

SUCTION PRESSURE

70/21

 

35

2.5

 

37

2.6

 

41

2.9

 

 

 

 

80/27

 

36

2.6

 

39

2.7

 

44

3.1

 

 

 

 

90/32

 

37

2.6

 

41

2.9

 

46

3.2

PSIG

kg/cm2G

100/38

 

38

2.7

 

42

3.0

 

50

3.5

TOTAL HEAT OF REJECTION FROM CONDENSER

 

15,400 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]

Note:

1.Pressure data is recorded at 5 minutes into freeze cycle. The data not in bold should be used for reference only.

2.We reserve the right to make changes in specifications and design without prior notice.

46

Image 46
Contents KM-901MAH KM-901MWH Hoshizaki AMERICA, INC Contents Page Page Indicates important information about the use and care Important Safety InformationSerious injury UnitSpecifications Icemaker 1a. KM-901MAH air-cooled Auxiliary Code T-0, U-01b. KM-901MAH air-cooled Auxiliary Code U-1 and Later 2a. KM-901MWH water-cooled Auxiliary Code T-0, U-0 Water Cooled Condenser2b. KM-901MWH water-cooled Auxiliary Code U-1 and Later 3a. KM-901MRH remote air-cooled Auxiliary Code T-0, U-0 3b. KM-901MRH remote air-cooled Auxiliary Code U-1 and Later 4a. KM-901MRH3 remote air-cooled Auxiliary Code T-0, U-0 4b. KM-901MRH remote air-cooled Auxiliary Code U-1 and Later Condenser Unit Specifications Model URC-9FII. General Information Construction KM-901MAH air-cooledKM-901MWH water-cooled KM-901MRH/3 remote air-cooled Sequence Cycles and Shutdown Sequence of OperationControl Board Auxiliary Code T-0, U-0 Shutdown Control Board Auxiliary Code U-1 and LaterOFF Cycle at Shutdown Mechanical Bin Control Activation Cycle Control Board Sequence Flow ChartSequence Flow Chart Bin FullMinute Harvest Cycle Freeze Cycle Pump-Out Cycle Control Board Auxiliary Code U-1Later Fill CycleControl Board Control Board Layout Control BoardPart Number 2A3792-01 Low Water Safety Harvest Backup Timer and Freeze TimerHigh Temperature Safety Maximum Water Supply Period 6 minutesSequence Step LED Lights and Audible Alarm SafetiesNo. of Beeps Type of Alarm Every 3 sec Energized Time LEDs are On Components Min Max AvgControl Board Auxiliary Code U-1 and Later Harvest Timer S4 dip switch 1 Controls and AdjustmentsDefault Dip Switch Settings S4 Dip Switch S4 Dip Switch NoPump-Out Frequency Control S4 dip switch 5 Pump-Out Timer S4 dip switch 3S4 Dip Switch Setting Time seconds Inlet Control Board S4 Dip Switch Setting Bin Control Bin Control Selector/Harvest Pump Timer S4 dip switchFactory Use S4 dip switch Control Board S4 Dip Switch Setting Pump Motor Time secondsRefill Counter S5 dip switch 2 through 5 G Control Board Freeze Timer S4 dip switch 9Float Switch Control S5 dip switch 1 G Control Board S4 Dip Switch Setting Time MinutesBin Control Float SwitchControl Switch ThermistorWater Pump Switch Discharge Line ModelCooled-AirWater-Cooled Model PressureHigh* Switch Wiring DiagramsKM-901MAH air-cooled and KM-901MWH water-cooled KM-901MRH remote air-cooled PressureSwitchHigh KM-901MRH3 remote air-cooled Switch Cooled-WaterModel Cooled-AirModel High* PressureHigh Pressure Switch SwitchPressure Performance Data 1480 912835 1570KM-901MRH remote air-cooled KM-901MRH3 remote air-cooled IV. Service Diagnosis Diagnostic ProcedurePage OFF Control Board Check Shutdown Thermostatic Bin Control Auxiliary Code T-0, U-0Bin Control Check Control Correct LED Board Lighting SequenceMechanical Bin Control Check Mechanical Bin Control Cleaning Float Switch Check and Cleaning Float Switch CheckFloat Switch Cleaning Thermistor Check Problem Possible Cause Remedy Diagnostic ChartsNo Ice Production Problem Possible Cause Remedy Problem Possible Cause Remedy Evaporator is Frozen Up Problem Possible Cause Remedy Low Ice Production Abnormal Ice Other Service for Refrigerant Lines Removal and Replacement of ComponentsRefrigerant Recovery Brazing Evacuation and Recharge R-404ARemoval and Replacement of Compressor Removal and Replacement of Expansion Valve Page Removal and Replacement of Evaporator Removal and Replacement of Air-Cooled Condenser Removal and Replacement of Water-Cooled Condenser Removal and Replacement of Remote Air-Cooled Condenser Page Adjustment of Water Regulating Valve water-cooled model Removal and Replacement of Thermistor Removal and Replacement of Inlet Water Valve Removal and Replacement of Pump Motor Removal and Replacement of Control Board VI. Cleaning and Maintenance Cleaning and Sanitizing InstructionsCleaning Procedure Sanitizing Procedure Following Cleaning Procedure Maintenance Preparing the Icemaker for Long StorageDrain the water tank