Hoshizaki KM-901MWH, KM-901MAH, KM-901MRH/3 service manual Removal and Replacement of Pump Motor

Page 81

12)Replace the front panel in its correct position.

13)Turn on the power supply.

O. Removal and Replacement of Pump Motor

1)Turn off the power supply.

2)Remove the front panel.

3)Remove the base cover, then disconnect one end of the pump tubing to drain the water tank. See Fig. 6. After the water tank has drained, reconnect the pump tubing.

5)Disconnect the pump suction and discharge hoses.

6)Remove the closed end connectors from the pump motor leads.

7)Remove the screw attaching the pump motor assembly to the base, then remove the pump motor assembly.

8)Remove the screw attaching the pump motor to the pump motor bracket.

9)Remove the screws attaching the pump housing to the pump motor. Remove the housing and check the impeller.

10)If the impeller is defective, install a new impeller.

11)Install the new motor or new parts, and replace the removed parts in the reverse order of which they were removed. Be sure to reattach the green ground wire.

12)Turn on the power supply and check for leaks.

13)Replace the base cover in its correct position.

14)Replace the front panel in its correct position.

Disconnect This

End of Pump

Tubing to Drain

Water Tank

Fig. 6

Base Cover

81

Image 81
Contents KM-901MAH KM-901MWH Hoshizaki AMERICA, INC Contents Page Page Serious injury Important Safety InformationIndicates important information about the use and care Unit1a. KM-901MAH air-cooled Auxiliary Code T-0, U-0 Specifications Icemaker1b. KM-901MAH air-cooled Auxiliary Code U-1 and Later Water Cooled Condenser 2a. KM-901MWH water-cooled Auxiliary Code T-0, U-02b. KM-901MWH water-cooled Auxiliary Code U-1 and Later 3a. KM-901MRH remote air-cooled Auxiliary Code T-0, U-0 3b. KM-901MRH remote air-cooled Auxiliary Code U-1 and Later 4a. KM-901MRH3 remote air-cooled Auxiliary Code T-0, U-0 4b. KM-901MRH remote air-cooled Auxiliary Code U-1 and Later Condenser Unit Model URC-9F SpecificationsKM-901MAH air-cooled II. General Information ConstructionKM-901MWH water-cooled KM-901MRH/3 remote air-cooled Sequence of Operation Sequence Cycles and ShutdownControl Board Auxiliary Code T-0, U-0 Control Board Auxiliary Code U-1 and Later ShutdownOFF Cycle at Shutdown Mechanical Bin Control Activation Sequence Flow Chart Control Board Sequence Flow ChartCycle Bin FullLater Control Board Auxiliary Code U-1Minute Harvest Cycle Freeze Cycle Pump-Out Cycle Fill CycleControl Board Control Board Control Board LayoutPart Number 2A3792-01 High Temperature Safety Harvest Backup Timer and Freeze TimerLow Water Safety Maximum Water Supply Period 6 minutesNo. of Beeps Type of Alarm Every 3 sec LED Lights and Audible Alarm SafetiesSequence Step Energized Time LEDs are On Components Min Max AvgControl Board Auxiliary Code U-1 and Later Default Dip Switch Settings Controls and AdjustmentsHarvest Timer S4 dip switch 1 S4 Dip Switch S4 Dip Switch NoPump-Out Timer S4 dip switch 3 Pump-Out Frequency Control S4 dip switch 5S4 Dip Switch Setting Time seconds Inlet Factory Use S4 dip switch Bin Control Selector/Harvest Pump Timer S4 dip switchControl Board S4 Dip Switch Setting Bin Control Control Board S4 Dip Switch Setting Pump Motor Time secondsFloat Switch Control S5 dip switch 1 G Control Board Freeze Timer S4 dip switch 9Refill Counter S5 dip switch 2 through 5 G Control Board S4 Dip Switch Setting Time MinutesControl Switch Float SwitchBin Control ThermistorWater Pump Switch Discharge Line Wiring Diagrams ModelCooled-AirWater-Cooled Model PressureHigh* SwitchKM-901MAH air-cooled and KM-901MWH water-cooled PressureSwitch KM-901MRH remote air-cooledHigh KM-901MRH3 remote air-cooled Cooled-AirModel High* Pressure Switch Cooled-WaterModelHigh Pressure Switch SwitchPressure Performance Data 835 9121480 1570KM-901MRH remote air-cooled KM-901MRH3 remote air-cooled Diagnostic Procedure IV. Service DiagnosisPage OFF Shutdown Thermostatic Bin Control Auxiliary Code T-0, U-0 Control Board CheckControl Correct LED Board Lighting Sequence Bin Control CheckMechanical Bin Control Check Mechanical Bin Control Cleaning Float Switch Check Float Switch Check and CleaningFloat Switch Cleaning Thermistor Check Diagnostic Charts Problem Possible Cause RemedyNo Ice Production Problem Possible Cause Remedy Problem Possible Cause Remedy Evaporator is Frozen Up Problem Possible Cause Remedy Low Ice Production Abnormal Ice Other Removal and Replacement of Components Service for Refrigerant LinesRefrigerant Recovery Evacuation and Recharge R-404A BrazingRemoval and Replacement of Compressor Removal and Replacement of Expansion Valve Page Removal and Replacement of Evaporator Removal and Replacement of Air-Cooled Condenser Removal and Replacement of Water-Cooled Condenser Removal and Replacement of Remote Air-Cooled Condenser Page Adjustment of Water Regulating Valve water-cooled model Removal and Replacement of Thermistor Removal and Replacement of Inlet Water Valve Removal and Replacement of Pump Motor Removal and Replacement of Control Board Cleaning and Sanitizing Instructions VI. Cleaning and MaintenanceCleaning Procedure Sanitizing Procedure Following Cleaning Procedure Preparing the Icemaker for Long Storage MaintenanceDrain the water tank