F. Diagnostic Charts
1. No Ice Production
Problem | Possible Cause |
| Remedy |
[1] The icemaker will not | a) Power Supply | 1. Off, blown fuse, or | 1. Turn on, replace, or reset. |
start. |
| tripped breaker. |
|
|
|
|
|
|
| 2. Loose connection. | 2. Tighten. |
|
|
|
|
|
| 3. Bad contacts. | 3. Check for continuity and |
|
|
| replace. |
|
|
|
|
|
| 4. Not within | 4. Refer to nameplate and |
|
| specifications. | correct. |
| b) Transformer (115V | 1. Voltage tap switch | 1. Verify incoming voltage, |
| primary) (3 phase only) | does not match | move switch to proper |
|
| incoming voltage. | setting. |
|
|
|
|
|
| 2. Coil winding open or | 2. Replace. |
|
| shorted. |
|
|
|
|
|
| c) Water Supply | 1. Water supply off or | 1. Check and get |
|
| pressure too low. | recommended pressure. |
|
|
|
|
| d) Thermostatic Bin | 1. Tripped with bin filled | 1. Remove ice. |
| Control | with ice. |
|
|
| 2. Ambient temperature | 2. Increase ambient |
|
| too cool. | temperature. |
|
|
|
|
|
| 3. Set too warm. | 3. See "IV.C.1. Thermostatic |
|
|
| Bin Control Check." |
|
|
|
|
|
| 4. Bulb out of position. | 4. Place in position. |
|
|
|
|
|
| 5. Bad contacts. | 5. Check for continuity and |
|
|
| replace. |
| e) Fuse (Control Box) | 1. Blown. | 1. Check for short circuit and |
|
|
| replace. |
| f) Control Switch | 1. "OFF" or "WASH" | 1. Move to "ICE" position. |
|
| position. |
|
|
|
|
|
|
| 2. Bad contacts. | 2. Check for continuity and |
|
|
| replace. |
|
|
|
|
| g) High Pressure Control | 1. Bad contacts. | 1. Check for continuity and |
|
|
| replace. |
|
|
|
|
|
| 2. Dirty air filter or | 2. Clean. |
|
| condenser. |
|
|
| 3. Ambient or condenser | 3. Reduce temperature. |
|
| water temperature too |
|
|
| warm. |
|
|
|
|
|
|
| 4. Refrigerant | 4. Recover, evacuate, and |
|
| overcharged. | recharge. |
|
|
|
|
|
| 5. Fan not operating | 5. See chart 1.[7]. |
|
| (except |
|
|
| model). |
|
|
|
|
|
|
| 6. Refrigerant lines or | 6. Recover, repair, replace |
|
| components restricted. | drier, evacuate and |
|
|
| recharge. |
|
| 7. Condenser water | 7. Check and get |
|
| pressure too low or off | recommended pressure. |
|
|
| |
|
|
|
|
60