Hoshizaki KM-901MWH Diagnostic Charts, No Ice Production, Problem Possible Cause Remedy

Page 60

F. Diagnostic Charts

1. No Ice Production

Problem

Possible Cause

 

Remedy

[1] The icemaker will not

a) Power Supply

1. Off, blown fuse, or

1. Turn on, replace, or reset.

start.

 

tripped breaker.

 

 

 

 

 

 

 

2. Loose connection.

2. Tighten.

 

 

 

 

 

 

3. Bad contacts.

3. Check for continuity and

 

 

 

replace.

 

 

 

 

 

 

4. Not within

4. Refer to nameplate and

 

 

specifications.

correct.

 

b) Transformer (115V

1. Voltage tap switch

1. Verify incoming voltage,

 

primary) (3 phase only)

does not match

move switch to proper

 

 

incoming voltage.

setting.

 

 

 

 

 

 

2. Coil winding open or

2. Replace.

 

 

shorted.

 

 

 

 

 

 

c) Water Supply

1. Water supply off or

1. Check and get

 

 

pressure too low.

recommended pressure.

 

 

 

 

 

d) Thermostatic Bin

1. Tripped with bin filled

1. Remove ice.

 

Control

with ice.

 

 

 

2. Ambient temperature

2. Increase ambient

 

 

too cool.

temperature.

 

 

 

 

 

 

3. Set too warm.

3. See "IV.C.1. Thermostatic

 

 

 

Bin Control Check."

 

 

 

 

 

 

4. Bulb out of position.

4. Place in position.

 

 

 

 

 

 

5. Bad contacts.

5. Check for continuity and

 

 

 

replace.

 

e) Fuse (Control Box)

1. Blown.

1. Check for short circuit and

 

 

 

replace.

 

f) Control Switch

1. "OFF" or "WASH"

1. Move to "ICE" position.

 

 

position.

 

 

 

 

 

 

 

2. Bad contacts.

2. Check for continuity and

 

 

 

replace.

 

 

 

 

 

g) High Pressure Control

1. Bad contacts.

1. Check for continuity and

 

 

 

replace.

 

 

 

 

 

 

2. Dirty air filter or

2. Clean.

 

 

condenser.

 

 

 

3. Ambient or condenser

3. Reduce temperature.

 

 

water temperature too

 

 

 

warm.

 

 

 

 

 

 

 

4. Refrigerant

4. Recover, evacuate, and

 

 

overcharged.

recharge.

 

 

 

 

 

 

5. Fan not operating

5. See chart 1.[7].

 

 

(except water-cooled

 

 

 

model).

 

 

 

 

 

 

 

6. Refrigerant lines or

6. Recover, repair, replace

 

 

components restricted.

drier, evacuate and

 

 

 

recharge.

 

 

7. Condenser water

7. Check and get

 

 

pressure too low or off

recommended pressure.

 

 

(water-cooled model).

 

 

 

 

 

60

Image 60
Contents KM-901MAH KM-901MWH Hoshizaki AMERICA, INC Contents Page Page Important Safety Information Serious injuryIndicates important information about the use and care UnitSpecifications Icemaker 1a. KM-901MAH air-cooled Auxiliary Code T-0, U-01b. KM-901MAH air-cooled Auxiliary Code U-1 and Later 2a. KM-901MWH water-cooled Auxiliary Code T-0, U-0 Water Cooled Condenser2b. KM-901MWH water-cooled Auxiliary Code U-1 and Later 3a. KM-901MRH remote air-cooled Auxiliary Code T-0, U-0 3b. KM-901MRH remote air-cooled Auxiliary Code U-1 and Later 4a. KM-901MRH3 remote air-cooled Auxiliary Code T-0, U-0 4b. KM-901MRH remote air-cooled Auxiliary Code U-1 and Later Condenser Unit Specifications Model URC-9FII. General Information Construction KM-901MAH air-cooledKM-901MWH water-cooled KM-901MRH/3 remote air-cooled Sequence of Operation Sequence Cycles and ShutdownControl Board Auxiliary Code T-0, U-0 Shutdown Control Board Auxiliary Code U-1 and LaterOFF Cycle at Shutdown Mechanical Bin Control Activation Control Board Sequence Flow Chart Sequence Flow ChartCycle Bin FullControl Board Auxiliary Code U-1 LaterMinute Harvest Cycle Freeze Cycle Pump-Out Cycle Fill CycleControl Board Control Board Layout Control BoardPart Number 2A3792-01 Harvest Backup Timer and Freeze Timer High Temperature SafetyLow Water Safety Maximum Water Supply Period 6 minutesLED Lights and Audible Alarm Safeties No. of Beeps Type of Alarm Every 3 secSequence Step Energized Time LEDs are On Components Min Max AvgControl Board Auxiliary Code U-1 and Later Controls and Adjustments Default Dip Switch SettingsHarvest Timer S4 dip switch 1 S4 Dip Switch S4 Dip Switch NoPump-Out Timer S4 dip switch 3 Pump-Out Frequency Control S4 dip switch 5S4 Dip Switch Setting Time seconds Inlet Bin Control Selector/Harvest Pump Timer S4 dip switch Factory Use S4 dip switchControl Board S4 Dip Switch Setting Bin Control Control Board S4 Dip Switch Setting Pump Motor Time secondsFreeze Timer S4 dip switch 9 Float Switch Control S5 dip switch 1 G Control BoardRefill Counter S5 dip switch 2 through 5 G Control Board S4 Dip Switch Setting Time MinutesFloat Switch Control SwitchBin Control ThermistorWater Pump Switch Discharge Line Wiring Diagrams ModelCooled-AirWater-Cooled Model PressureHigh* SwitchKM-901MAH air-cooled and KM-901MWH water-cooled PressureSwitch KM-901MRH remote air-cooledHigh KM-901MRH3 remote air-cooled Switch Cooled-WaterModel Cooled-AirModel High* PressureHigh Pressure Switch SwitchPressure Performance Data 912 8351480 1570KM-901MRH remote air-cooled KM-901MRH3 remote air-cooled IV. Service Diagnosis Diagnostic ProcedurePage OFF Control Board Check Shutdown Thermostatic Bin Control Auxiliary Code T-0, U-0Bin Control Check Control Correct LED Board Lighting SequenceMechanical Bin Control Check Mechanical Bin Control Cleaning Float Switch Check and Cleaning Float Switch CheckFloat Switch Cleaning Thermistor Check Diagnostic Charts Problem Possible Cause RemedyNo Ice Production Problem Possible Cause Remedy Problem Possible Cause Remedy Evaporator is Frozen Up Problem Possible Cause Remedy Low Ice Production Abnormal Ice Other Removal and Replacement of Components Service for Refrigerant LinesRefrigerant Recovery Brazing Evacuation and Recharge R-404ARemoval and Replacement of Compressor Removal and Replacement of Expansion Valve Page Removal and Replacement of Evaporator Removal and Replacement of Air-Cooled Condenser Removal and Replacement of Water-Cooled Condenser Removal and Replacement of Remote Air-Cooled Condenser Page Adjustment of Water Regulating Valve water-cooled model Removal and Replacement of Thermistor Removal and Replacement of Inlet Water Valve Removal and Replacement of Pump Motor Removal and Replacement of Control Board VI. Cleaning and Maintenance Cleaning and Sanitizing InstructionsCleaning Procedure Sanitizing Procedure Following Cleaning Procedure Maintenance Preparing the Icemaker for Long StorageDrain the water tank