Hoshizaki KM-901MWH Pump-Out Timer S4 dip switch 3, Pump-Out Frequency Control S4 dip switch 5

Page 33

c)Pump-Out Timer (S4 dip switch 3 & 4)

When a pump-out is called for, the pump motor de-energizes after the preceding freeze cycle. The pump motor energizes 2 seconds later in the reverse direction, taking water from the bottom of the tank and forcing pressure against the check valve seat allowing water to go through the check valve and down the drain. At the same time, water flows through the small tube to power flush the float switch. The pump motor drains the water tank for the time determined by the pump-out timer. The pumpout timer also acts in place of the harvest timer during cycles with a pump-out. The pump-out timer is factory set, and generally no adjustment is required. However, where water quality is bad and the icemaker needs a longer pump-out time, the pump-out timer can be adjusted. The pumpout timer control can be set to pump-out for 10 or 20 seconds.

S4 Dip Switch Setting

Time (seconds)

Inlet

Water

 

 

 

 

 

 

 

 

No. 3

No. 4

T1

T2

Valve

OFF

OFF

10

150

Closed

 

 

 

 

 

ON

OFF

10

180

Closed

 

 

 

 

 

OFF

ON

10

120

Open

 

 

 

 

 

ON

ON

20

180

Closed

T1: Time to drain the water tank

T2: Harvest timer at pump-out

d)Pump-Out Frequency Control (S4 dip switch 5 & 6)

The pump-out frequency control is factory set to drain the water tank every 10 cycles, and generally no adjustment is required. However, where water quality is bad and the icemaker needs a pump-out more often, the pump-out frequency can be adjusted. The pump-out frequency control can be set to have a pump-out occur every cycle, or every 2, 5, or 10 cycles.

Timing of the first pump-out is dependent on the control board. "E" control board first pumpout is after the first freeze cycle. "G" control board first pump-out is dependent on S4 dip switch 5 & 6. See the table below.

"E" & "G" Control Board Settings

1st Pump-Out

S4 Dip Switch Setting

Pump-Out

"E" Control Board

"G" Control Board

No. 5

No. 6

Frequency

 

 

 

 

 

 

 

OFF

OFF

Every cycle

After 1st freeze cycle

After 2nd freeze cycle

 

 

 

 

 

ON

OFF

Every 2 cycles

 

After 3rd freeze cycle

OFF

ON

Every 5 cycles

 

After 6th freeze cycle

 

 

 

 

 

ON

ON

Every 10 cycles

 

After 11th freeze cycle

 

 

 

 

 

33

Image 33
Contents KM-901MAH KM-901MWH Hoshizaki AMERICA, INC Contents Page Page Serious injury Important Safety InformationIndicates important information about the use and care Unit1a. KM-901MAH air-cooled Auxiliary Code T-0, U-0 Specifications Icemaker1b. KM-901MAH air-cooled Auxiliary Code U-1 and Later Water Cooled Condenser 2a. KM-901MWH water-cooled Auxiliary Code T-0, U-02b. KM-901MWH water-cooled Auxiliary Code U-1 and Later 3a. KM-901MRH remote air-cooled Auxiliary Code T-0, U-0 3b. KM-901MRH remote air-cooled Auxiliary Code U-1 and Later 4a. KM-901MRH3 remote air-cooled Auxiliary Code T-0, U-0 4b. KM-901MRH remote air-cooled Auxiliary Code U-1 and Later Condenser Unit Model URC-9F SpecificationsKM-901MAH air-cooled II. General Information ConstructionKM-901MWH water-cooled KM-901MRH/3 remote air-cooled Sequence of Operation Sequence Cycles and ShutdownControl Board Auxiliary Code T-0, U-0 Control Board Auxiliary Code U-1 and Later ShutdownOFF Cycle at Shutdown Mechanical Bin Control Activation Sequence Flow Chart Control Board Sequence Flow ChartCycle Bin FullLater Control Board Auxiliary Code U-1Minute Harvest Cycle Freeze Cycle Pump-Out Cycle Fill CycleControl Board Control Board Control Board LayoutPart Number 2A3792-01 High Temperature Safety Harvest Backup Timer and Freeze TimerLow Water Safety Maximum Water Supply Period 6 minutesNo. of Beeps Type of Alarm Every 3 sec LED Lights and Audible Alarm SafetiesSequence Step Energized Time LEDs are On Components Min Max AvgControl Board Auxiliary Code U-1 and Later Default Dip Switch Settings Controls and AdjustmentsHarvest Timer S4 dip switch 1 S4 Dip Switch S4 Dip Switch NoPump-Out Timer S4 dip switch 3 Pump-Out Frequency Control S4 dip switch 5S4 Dip Switch Setting Time seconds Inlet Factory Use S4 dip switch Bin Control Selector/Harvest Pump Timer S4 dip switchControl Board S4 Dip Switch Setting Bin Control Control Board S4 Dip Switch Setting Pump Motor Time secondsFloat Switch Control S5 dip switch 1 G Control Board Freeze Timer S4 dip switch 9Refill Counter S5 dip switch 2 through 5 G Control Board S4 Dip Switch Setting Time MinutesControl Switch Float SwitchBin Control ThermistorWater Pump Switch Discharge Line Wiring Diagrams ModelCooled-AirWater-Cooled Model PressureHigh* SwitchKM-901MAH air-cooled and KM-901MWH water-cooled PressureSwitch KM-901MRH remote air-cooledHigh KM-901MRH3 remote air-cooled Cooled-AirModel High* Pressure Switch Cooled-WaterModelHigh Pressure Switch SwitchPressure Performance Data 835 9121480 1570KM-901MRH remote air-cooled KM-901MRH3 remote air-cooled Diagnostic Procedure IV. Service DiagnosisPage OFF Shutdown Thermostatic Bin Control Auxiliary Code T-0, U-0 Control Board CheckControl Correct LED Board Lighting Sequence Bin Control CheckMechanical Bin Control Check Mechanical Bin Control Cleaning Float Switch Check Float Switch Check and CleaningFloat Switch Cleaning Thermistor Check Diagnostic Charts Problem Possible Cause RemedyNo Ice Production Problem Possible Cause Remedy Problem Possible Cause Remedy Evaporator is Frozen Up Problem Possible Cause Remedy Low Ice Production Abnormal Ice Other Removal and Replacement of Components Service for Refrigerant LinesRefrigerant Recovery Evacuation and Recharge R-404A BrazingRemoval and Replacement of Compressor Removal and Replacement of Expansion Valve Page Removal and Replacement of Evaporator Removal and Replacement of Air-Cooled Condenser Removal and Replacement of Water-Cooled Condenser Removal and Replacement of Remote Air-Cooled Condenser Page Adjustment of Water Regulating Valve water-cooled model Removal and Replacement of Thermistor Removal and Replacement of Inlet Water Valve Removal and Replacement of Pump Motor Removal and Replacement of Control Board Cleaning and Sanitizing Instructions VI. Cleaning and MaintenanceCleaning Procedure Sanitizing Procedure Following Cleaning Procedure Preparing the Icemaker for Long Storage MaintenanceDrain the water tank