Hoshizaki KM-901MAH, KM-901MWH, KM-901MRH/3 service manual KM-901MRH3 remote air-cooled

Page 49

4. KM-901MRH3 (remote air-cooled)

APPROXIMATE ICE

AMBIENT TEMP.

 

 

WATER TEMP. (ºF/ºC)

 

 

PRODUCTION PER 24 HR.

(ºF/ºC)

 

50/10

 

 

70/21

 

 

90/32

 

 

 

 

70/21

899

408

 

874

397

 

817

371

 

 

 

 

80/27

880

399

 

842

382

 

772

350

 

 

 

 

90/32

874

397

 

815

370

 

749

340

lbs./day

 

kg./day

100/38

855

388

 

800

363

 

689

313

 

 

 

 

 

 

 

 

 

 

 

 

APPROXIMATE ELECTRIC

70/21

 

1670

 

 

1717

 

 

1755

CONSUMPTION

80/27

 

1706

 

 

1779

 

 

1803

 

 

 

 

90/32

 

1717

 

 

1830

 

 

1861

watts

 

 

 

100/38

 

1716

 

 

1837

 

 

1890

APPROXIMATE WATER

70/21

254

0.96

 

222

0.84

 

203

0.77

CONSUMPTION PER 24 HR.

80/27

230

0.87

 

181

0.69

 

174

0.66

 

 

 

 

90/32

222

0.84

 

147

0.56

 

134

0.51

gal./day

 

m3/day

100/38

185

0.70

 

144

0.54

 

123

0.46

FREEZING CYCLE TIME

70/21

 

19

 

 

20

 

 

21

 

 

 

 

80/27

 

20

 

 

21

 

 

23

 

 

 

 

90/32

 

20

 

 

22

 

 

24

min.

 

 

 

100/38

 

20

 

 

23

 

 

26

HARVEST CYCLE TIME

70/21

 

4.4

 

 

3.9

 

 

3.6

 

 

 

 

80/27

 

4.0

 

 

3.3

 

 

3.2

 

 

 

 

90/32

 

3.9

 

 

2.8

 

 

2.6

min.

 

 

 

100/38

 

3.4

 

 

2.7

 

 

2.4

HEAD PRESSURE

70/21

206

14.5

 

225

15.8

 

248

17.5

 

 

 

 

80/27

220

15.5

 

249

17.5

 

272

19.1

 

 

 

 

90/32

225

15.8

 

270

19.0

 

293

20.6

PSIG

kg/cm2G

100/38

229

16.1

 

275

19.4

 

315

22.1

SUCTION PRESSURE

70/21

36

2.5

 

38

2.7

 

41

2.9

 

 

 

 

80/27

37

2.6

 

40

2.8

 

44

3.1

 

 

 

 

90/32

38

2.7

 

42

3.0

 

46

3.2

PSIG

kg/cm2G

100/38

39

2.7

 

43

3.0

 

49

3.4

TOTAL HEAT OF REJECTION FROM CONDENSER

14,100

BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]

TOTAL HEAT OF REJECTION FROM COMPRESSOR

2,200

BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]

CONDENSER VOLUME

121

CU. IN (URC-9F)

Note:

1.Pressure data is recorded at 5 minutes into freeze cycle. The data not in bold should be used for reference only.

2.We reserve the right to make changes in specifications and design without prior notice.

49

Image 49
Contents KM-901MAH KM-901MWH Hoshizaki AMERICA, INC Contents Page Page Serious injury Important Safety InformationIndicates important information about the use and care Unit1a. KM-901MAH air-cooled Auxiliary Code T-0, U-0 Specifications Icemaker1b. KM-901MAH air-cooled Auxiliary Code U-1 and Later Water Cooled Condenser 2a. KM-901MWH water-cooled Auxiliary Code T-0, U-02b. KM-901MWH water-cooled Auxiliary Code U-1 and Later 3a. KM-901MRH remote air-cooled Auxiliary Code T-0, U-0 3b. KM-901MRH remote air-cooled Auxiliary Code U-1 and Later 4a. KM-901MRH3 remote air-cooled Auxiliary Code T-0, U-0 4b. KM-901MRH remote air-cooled Auxiliary Code U-1 and Later Condenser Unit Model URC-9F SpecificationsKM-901MAH air-cooled II. General Information ConstructionKM-901MWH water-cooled KM-901MRH/3 remote air-cooled Sequence Cycles and Shutdown Sequence of OperationControl Board Auxiliary Code T-0, U-0 Control Board Auxiliary Code U-1 and Later ShutdownOFF Cycle at Shutdown Mechanical Bin Control Activation Sequence Flow Chart Control Board Sequence Flow ChartCycle Bin FullLater Control Board Auxiliary Code U-1Minute Harvest Cycle Freeze Cycle Pump-Out Cycle Fill CycleControl Board Control Board Control Board LayoutPart Number 2A3792-01 High Temperature Safety Harvest Backup Timer and Freeze TimerLow Water Safety Maximum Water Supply Period 6 minutesNo. of Beeps Type of Alarm Every 3 sec LED Lights and Audible Alarm SafetiesSequence Step Energized Time LEDs are On Components Min Max AvgControl Board Auxiliary Code U-1 and Later Default Dip Switch Settings Controls and AdjustmentsHarvest Timer S4 dip switch 1 S4 Dip Switch S4 Dip Switch NoPump-Out Frequency Control S4 dip switch 5 Pump-Out Timer S4 dip switch 3S4 Dip Switch Setting Time seconds Inlet Factory Use S4 dip switch Bin Control Selector/Harvest Pump Timer S4 dip switchControl Board S4 Dip Switch Setting Bin Control Control Board S4 Dip Switch Setting Pump Motor Time secondsFloat Switch Control S5 dip switch 1 G Control Board Freeze Timer S4 dip switch 9Refill Counter S5 dip switch 2 through 5 G Control Board S4 Dip Switch Setting Time MinutesControl Switch Float SwitchBin Control ThermistorWater Pump Switch Discharge Line ModelCooled-AirWater-Cooled Model PressureHigh* Switch Wiring DiagramsKM-901MAH air-cooled and KM-901MWH water-cooled KM-901MRH remote air-cooled PressureSwitchHigh KM-901MRH3 remote air-cooled Cooled-AirModel High* Pressure Switch Cooled-WaterModelHigh Pressure Switch SwitchPressure Performance Data 835 9121480 1570KM-901MRH remote air-cooled KM-901MRH3 remote air-cooled Diagnostic Procedure IV. Service DiagnosisPage OFF Shutdown Thermostatic Bin Control Auxiliary Code T-0, U-0 Control Board CheckControl Correct LED Board Lighting Sequence Bin Control CheckMechanical Bin Control Check Mechanical Bin Control Cleaning Float Switch Check Float Switch Check and CleaningFloat Switch Cleaning Thermistor Check Problem Possible Cause Remedy Diagnostic ChartsNo Ice Production Problem Possible Cause Remedy Problem Possible Cause Remedy Evaporator is Frozen Up Problem Possible Cause Remedy Low Ice Production Abnormal Ice Other Service for Refrigerant Lines Removal and Replacement of ComponentsRefrigerant Recovery Evacuation and Recharge R-404A BrazingRemoval and Replacement of Compressor Removal and Replacement of Expansion Valve Page Removal and Replacement of Evaporator Removal and Replacement of Air-Cooled Condenser Removal and Replacement of Water-Cooled Condenser Removal and Replacement of Remote Air-Cooled Condenser Page Adjustment of Water Regulating Valve water-cooled model Removal and Replacement of Thermistor Removal and Replacement of Inlet Water Valve Removal and Replacement of Pump Motor Removal and Replacement of Control Board Cleaning and Sanitizing Instructions VI. Cleaning and MaintenanceCleaning Procedure Sanitizing Procedure Following Cleaning Procedure Preparing the Icemaker for Long Storage MaintenanceDrain the water tank