Scotsman Ice CME1356R, CME1656R specifications Electrical

Page 14

CME1356R and CME1656R

Electrical

All models must be installed with the correct wire size and type per the National Electric Code. Locate the nameplate on the back of the cabinet and find the numbers for Voltage, Phase, Minimum Circuit Ampacity and Maximum Fuse Size. Either fuses or HACR type circuit breakers may be used.

The ice maker is designed to operate on its own electrical circuit and must be individually fused. Voltage variation must not exceed the limits listed on page 2.

The remote condenser is designed to be powered from the ice machine. A separate knockout hole has been provided in the ice maker electrical junction box.

Remote Condenser

Power Connection

Note: Central Condensers connected to more than one refrigeration system will likely have a wiring scheme to control the fan motor. Follow those directions for condenser wiring.

Electrical connections are made in the junction box in the back of the cabinet.

1.Remove the junction box cover.

2.Knock out both holes for a field supplied strain relief.

3.Install wires and strain reliefs per code. Note: Condenser fan motor wires are tagged.

4.Connect to wires and secure ground wire to ground screw inside junction box.

All external wiring should conform to the national, state and local electrical code requirements. Usually an electrical permit and the services of a licensed electrician will be required.

Power Supply

Interconnecting

Wire

May 2001

Page 14

Image 14
Contents CME1356R and CME1656R CME1356R and CME1656R CME1356R and CME1656R Condenser and Ice Machine LayoutsPre-Installation Serial Number PlateLocation & Assembly Bin Control Installation Bin Control Mount BulbStacking Kit KSCME6-LG-B Stacking For The Installer Remote Condenser CME1356R and CME1656R Coupling Instructions Tighten Swivel NutHead Pressure Control Add-On Kit Electrical Drain PlumbingSupply Water Filters Follow all applicable codesAfter Utility Connections Final Check ListComponent Location and Function AutoIQ Controller Freeze Cycle Initial Start UpInitial Start 30 seconds Harvest CycleHow to Adjust the Amount of Water Purge AdjustmentsIf there was a problem during Initial Start Up How To Operate The AutoIQ Controller How The Electronic Cuber Works Refrigeration SystemHigh Voltage Water SystemVolt Technicians Only Freeze Cycle Sequence AutoIQ Controller Operation, Beginning freezeWater Light Refrigeration Technicians Only Harvest Cycle Sequence & Other NotesHarvest LightSanitation and Cleaning To drain reservoir if desired Additional MaintenanceTo Properly Place the Evaporator Covers Additional Maintenance Water Distributors Additional Maintenance Inlet Water Valve Screen Additional Maintenance Ice Sensors, Condenser To Clean the Remote Air Cooled CondenserService Diagnosis Diagnostic Light Analysis Problem or Symptom Possible Cause Probable CorrectionService Diagnosis Service Diagnosis Components TXV March Operational Characteristics CME1356R Operational Characteristics CME1656R Removal and Replacement Water Level Sensor/Float Stem Removal and Replacement AutoIQ Controller Removal and Replacement Water Level Sensor Removal and Replacement Refrigerant Liquid Charging Before Calling for Service Check the followingService Bulletin