Scotsman Ice CME1656R Initial Start Up, Initial Start 30 seconds, Freeze Cycle, Harvest Cycle

Page 19

CME1356R and CME1656R

Initial Start Up

1.Remove the left front panel.

2.Locate and open the liquid line valve.

Open By Turning

Stem Fully Out (Up)

Service

Port

3.Double check quick-connect couplings for leaks.

4.Locate the AutoIQ Controller.

5.Connect electrical power. All lights will blink on and off together then, for blue controllers, the two red lights will blink while the Freeze light is on.

After 20 seconds the Freeze light will go out and the Bin Full and Off lights will be on. After a few seconds only the Off light will be glowing.

6.Open the water supply valve.

7.Push and release the Freeze cycle push button (the Freeze indicator light will blink until the compressor starts).

Initial Start (30 seconds)

￿The Freeze light will begin to blink.

￿The hot gas solenoid valve will be open.

￿The purge valve will be open

￿The water pump will be on

￿After 30 seconds, the hot gas valve closes

￿The purge valve will shut and the inlet water valve will open to fill the reservoir. The inlet water valve shuts off when the reservoir is full.

￿The compressor & remote fan motor start.

Freeze Cycle

The Freeze indicator light will come on. The unit will be in a Freeze cycle for many minutes. Slush may appear in the reservoir, it is temporary and normal.

￿The pump will stop for a few seconds a few minutes into the freeze cycle

￿The freeze cycle will continue until the water level in the reservoir drops to its factory set point, the first time that happens the water valve will re-fill the reservoir. The second time it happens in a freeze cycle starts the Harvest Cycle.

Harvest Cycle:

￿The Harvest indicator light will be ON,

￿The hot gas valve will open.

￿The purge valve will be open for 74 seconds.

￿The water pump will switch off. The pump will restart part way thru the harvest cycle.

￿The purge valve closes.

￿The Inlet water valve will open for a short time

￿The Bin Full indicator light will go on and off as ice falls from the evaporators.

8.Machines are shipped from the factory with the purge level set to accommodate average water conditions. To achieve optimal machine performance, set the purge level to the minimum setting.

Note: While the amount of water purge is adjustable, only those installations with a water supply known to be excellent (very low TDS) should adjust to the minimum setting. See the next page for purge adjustment procedures.

9.After about 6 minutes (first cycle after any restart) the machine will return to a freeze cycle. Note: After the first harvest, the controller will adjusts harvest time as needed to release all ice.

10.The reservoir refills at the beginning of Freeze.

11.Fill out the Customer Evaluation and Warranty Registration. Send it to Scotsman.

12.Return all panels to their normal positions.

13.Inform the user of the location and telephone number of the local service company. Inform the user of the required maintenance of the machine.

Operational Notes:

1.The machine will only shut off on Bin Full at the end of the Harvest Cycle after the bin fills. That last harvest cycle will be about 6 minutes long.

2.After switching off on Bin Full, if ice is removed from the bin, the machine will not restart until it has been off for 4 minutes. If the Freeze button is pushed, the machine will restart immediately.

3.If the bin controls sense a bin full signal before any water is used (float stem up), the machine will shut off on bin full.

4.When shutting off, the compressor will run for 30 seconds (everything else will be off) and then switch off.

March 2003

Page 19

Image 19
Contents CME1356R and CME1656R CME1356R and CME1656R Condenser and Ice Machine Layouts CME1356R and CME1656RSerial Number Plate Pre-InstallationLocation & Assembly Bin Control Installation Mount Bulb Bin ControlStacking Kit KSCME6-LG-B Stacking For The Installer Remote Condenser CME1356R and CME1656R Tighten Swivel Nut Coupling InstructionsHead Pressure Control Add-On Kit Electrical Water Filters Follow all applicable codes PlumbingSupply DrainFinal Check List After Utility ConnectionsComponent Location and Function AutoIQ Controller Harvest Cycle Initial Start UpInitial Start 30 seconds Freeze CycleIf there was a problem during Initial Start Up AdjustmentsHow to Adjust the Amount of Water Purge How To Operate The AutoIQ Controller Refrigeration System How The Electronic Cuber WorksVolt Water SystemHigh Voltage AutoIQ Controller Operation, Beginning freeze Technicians Only Freeze Cycle SequenceLight Technicians Only Harvest Cycle Sequence & Other NotesHarvest Water Light RefrigerationSanitation and Cleaning To Properly Place the Evaporator Covers Additional MaintenanceTo drain reservoir if desired Additional Maintenance Water Distributors Additional Maintenance Inlet Water Valve Screen To Clean the Remote Air Cooled Condenser Additional Maintenance Ice Sensors, CondenserProblem or Symptom Possible Cause Probable Correction Service Diagnosis Diagnostic Light AnalysisService Diagnosis Service Diagnosis Components TXV March Operational Characteristics CME1356R Operational Characteristics CME1656R Removal and Replacement Water Level Sensor/Float Stem Removal and Replacement AutoIQ Controller Removal and Replacement Water Level Sensor Removal and Replacement Refrigerant Liquid Charging Check the following Before Calling for ServiceService Bulletin