Scotsman Ice CME1356R, CME1656R specifications How The Electronic Cuber Works, Refrigeration System

Page 22

CME1356R and CME1656R

How The Electronic Cuber Works

This section is intended for the technician. It is not necessary for the normal operation and maintenance of the machine.

Refrigeration System:

The refrigeration system is similar to that of most commercial cube ice machines. Heat is removed from the water and discharged out the condenser during the freeze cycle. As liquid refrigerant passes thru the Thermostatic Expansion Valve, it enters the top of the evaporators, and ice will form at the top first.

When cubes need to be released (Harvest) the Hot Gas Valve is opened and Hot discharge gas flows directly from the compressor to the evaporator inlets. At the same time, a Harvest Bypass Valve opens for a few seconds to add the refrigerant needed for harvest. After that the Harvest Bypass Valve and the closed Discharge Check Valve keeps the refrigerant in the condenser out of the Hot Gas Circuit.

Harvest

Bypass

Valve

Discharge Line

Receiver

Check

Valve

Remote Condenser

Head

Pressure

Control

Valve

Check

Valve

Heat

Exchange

This warms up the evaporators and the surface of the ice frozen to the evaporator surface melts. Ice then falls into the bin.

The Check Valves also prevent liquid migration during the Off cycle.

Thermostatic

Expansion

Valve

Refrigerant

Distributor

Evaporator

Suction

Process Port

Evaporator

Accumulator

 

Hot Gas

Evaporator

Valve

 

Compressor

Refrigeration Schematic

May 2001

Page 22

Image 22
Contents CME1356R and CME1656R CME1356R and CME1656R CME1356R and CME1656R Condenser and Ice Machine LayoutsPre-Installation Serial Number PlateLocation & Assembly Bin Control Installation Bin Control Mount BulbStacking Kit KSCME6-LG-B Stacking For The Installer Remote Condenser CME1356R and CME1656R Coupling Instructions Tighten Swivel NutHead Pressure Control Add-On Kit Electrical Drain PlumbingSupply Water Filters Follow all applicable codesAfter Utility Connections Final Check ListComponent Location and Function AutoIQ Controller Freeze Cycle Initial Start UpInitial Start 30 seconds Harvest CycleIf there was a problem during Initial Start Up AdjustmentsHow to Adjust the Amount of Water Purge How To Operate The AutoIQ Controller How The Electronic Cuber Works Refrigeration SystemVolt Water SystemHigh Voltage Technicians Only Freeze Cycle Sequence AutoIQ Controller Operation, Beginning freezeWater Light Refrigeration Technicians Only Harvest Cycle Sequence & Other NotesHarvest LightSanitation and Cleaning To Properly Place the Evaporator Covers Additional MaintenanceTo drain reservoir if desired Additional Maintenance Water Distributors Additional Maintenance Inlet Water Valve Screen Additional Maintenance Ice Sensors, Condenser To Clean the Remote Air Cooled CondenserService Diagnosis Diagnostic Light Analysis Problem or Symptom Possible Cause Probable CorrectionService Diagnosis Service Diagnosis Components TXV March Operational Characteristics CME1356R Operational Characteristics CME1656R Removal and Replacement Water Level Sensor/Float Stem Removal and Replacement AutoIQ Controller Removal and Replacement Water Level Sensor Removal and Replacement Refrigerant Liquid Charging Before Calling for Service Check the followingService Bulletin