Scotsman Ice CME1656R, CME1356R specifications Water Level Sensor/Float Stem

Page 39

CME1356R and CME1656R

Removal and Replacement

Purge Valve

Electrical Shock Hazard. Disconnect electrical power before beginning service.

1.Disconnect electrical power.

2.Remove left front panel.

3.Unplug wire harness from purge valve coil.

4.Locate and remove the two screws securing the purge valve to the machine.

5.Pull the inlet and outlet hoses off the purge valve and remove it from the machine.

6.Reverse to reassemble. There are no internal parts available for this valve.

Purge Valve Timer

The purge valve timer is sensitive to electrostatic discharge. Be certain to touch a grounded surface before touching this component. Do the same when handling the replacement part.

1.Touch a grounded surface.

2.Remove left front panel.

3.Disconnect electrical power.

4.Remove high voltage box cover.

5.Locate timer board at the back of the high voltage box.

6.Unplug all the wires to the board.

7.Compress each of the four stand-off posts to release the board from the stand-offs.

8.Remove the board from the unit.

Reverse to reassemble.

Water Level Sensor/Float Stem

1.Disconnect the electrical power.

2.Remove the front panel.

3.Remove 1 plastic bolt and the reservoir cover.

4.Pull float ball from float stem (it is a snap fit). Pull stem out.

5.Locate water level sensor mounting tabs, compress together to release sensor from bracket.

6.Remove harness from sensor.

7.Reverse to replace.

8.Replace front panel.

9.Reconnect electrical power.

March 2003

Page 39

Image 39
Contents CME1356R and CME1656R CME1356R and CME1656R Condenser and Ice Machine Layouts CME1356R and CME1656RSerial Number Plate Pre-InstallationLocation & Assembly Bin Control Installation Mount Bulb Bin ControlStacking Kit KSCME6-LG-B Stacking For The Installer Remote Condenser CME1356R and CME1656R Tighten Swivel Nut Coupling InstructionsHead Pressure Control Add-On Kit Electrical Water Filters Follow all applicable codes PlumbingSupply DrainFinal Check List After Utility ConnectionsComponent Location and Function AutoIQ Controller Harvest Cycle Initial Start UpInitial Start 30 seconds Freeze CycleAdjustments If there was a problem during Initial Start UpHow to Adjust the Amount of Water Purge How To Operate The AutoIQ Controller Refrigeration System How The Electronic Cuber WorksWater System VoltHigh Voltage AutoIQ Controller Operation, Beginning freeze Technicians Only Freeze Cycle SequenceLight Technicians Only Harvest Cycle Sequence & Other NotesHarvest Water Light RefrigerationSanitation and Cleaning Additional Maintenance To Properly Place the Evaporator CoversTo drain reservoir if desired Additional Maintenance Water Distributors Additional Maintenance Inlet Water Valve Screen To Clean the Remote Air Cooled Condenser Additional Maintenance Ice Sensors, CondenserProblem or Symptom Possible Cause Probable Correction Service Diagnosis Diagnostic Light AnalysisService Diagnosis Service Diagnosis Components TXV March Operational Characteristics CME1356R Operational Characteristics CME1656R Removal and Replacement Water Level Sensor/Float Stem Removal and Replacement AutoIQ Controller Removal and Replacement Water Level Sensor Removal and Replacement Refrigerant Liquid Charging Check the following Before Calling for ServiceService Bulletin