Scotsman Ice CME1356R, CME1656R specifications Bin Control Installation

Page 6

CME1356R and CME1656R

Bin Control: Installation

The bin control is a thermostat. It must be field installed after the ice machine has been placed on the bin.

Before starting, remove the left front panel and any baffle in the bin.

1.Locate bin thermostat bulb.

2.Route bulb thru routing tube (located between the compressor and the reservoir).

3.Locate bin thermostat bracket.

4.Carefully position the thermostat bulb on the bracket (see the diagram on the next page).

5.Fasten the bracket to the bottom of the ice machine with the two 3-pronged knobs supplied with the unit.

6.Pull back into the ice machine any excess capillary tubing.

7.Return the baffle to the bin and continue with the installation.

Note: If the machine is located at an altitude higher than 2,000 ft., adjust the thermostat by removing the plastic cover and rotating the adjustment screw per the table.

Thermostat Bulb Routing Tube

Bin Thermostat Altitude Correction Table

CW Turns of Range Screw (under plastic cover)

Feet

Turns

Feet

Turns

 

 

 

 

2000

55o

8000

340o

4000

160o

9000

385o

6000

250o

10000

405o

Use This Table to Adjust Thermostat

Bin Thermostat Bulb

Bin

Thermostat

Body

Thermostat Bulb

Routing Tube

Route Bin Thermostat Bulb Into Bin

May 2001

Page 6

Image 6
Contents CME1356R and CME1656R CME1356R and CME1656R CME1356R and CME1656R Condenser and Ice Machine LayoutsPre-Installation Serial Number PlateLocation & Assembly Bin Control Installation Bin Control Mount BulbStacking Kit KSCME6-LG-B Stacking For The Installer Remote Condenser CME1356R and CME1656R Coupling Instructions Tighten Swivel NutHead Pressure Control Add-On Kit Electrical Drain PlumbingSupply Water Filters Follow all applicable codesAfter Utility Connections Final Check ListComponent Location and Function AutoIQ Controller Freeze Cycle Initial Start UpInitial Start 30 seconds Harvest CycleAdjustments If there was a problem during Initial Start UpHow to Adjust the Amount of Water Purge How To Operate The AutoIQ Controller How The Electronic Cuber Works Refrigeration SystemWater System VoltHigh Voltage Technicians Only Freeze Cycle Sequence AutoIQ Controller Operation, Beginning freezeWater Light Refrigeration Technicians Only Harvest Cycle Sequence & Other NotesHarvest LightSanitation and Cleaning Additional Maintenance To Properly Place the Evaporator CoversTo drain reservoir if desired Additional Maintenance Water Distributors Additional Maintenance Inlet Water Valve Screen Additional Maintenance Ice Sensors, Condenser To Clean the Remote Air Cooled CondenserService Diagnosis Diagnostic Light Analysis Problem or Symptom Possible Cause Probable CorrectionService Diagnosis Service Diagnosis Components TXV March Operational Characteristics CME1356R Operational Characteristics CME1656R Removal and Replacement Water Level Sensor/Float Stem Removal and Replacement AutoIQ Controller Removal and Replacement Water Level Sensor Removal and Replacement Refrigerant Liquid Charging Before Calling for Service Check the followingService Bulletin