Scotsman Ice specifications CME1356R and CME1656R

Page 2

CME1356R and CME1656R

Specifications

Both of these ice machines are designed to be installed indoors, in a controlled environment. They can operate satisfactorily under a wide variety of conditions. However, Do NOT operate the machine in temperatures it has not been designed for. Do NOT operate the machine above or below the voltage limits for the particular model. Do NOT operate the machine with too little or too much water pressure.

Operational Limits

 

Minimum

Maximum

 

 

 

Air Temperature

50oF.

100oF.

Water Temperature

40oF.

100oF.

Water Pressure

20 psi

80 psi

 

 

 

Voltage (60 Hz)

197

253

 

 

 

Voltage (50 Hz)

207

253

 

 

 

 

 

 

Scotsman reserves the right to make design changes and/or improvements at any time. Specifications and designs are subject to change without notice.

Scotsman assumes no liability or responsibility of any kind for products manufactured by Scotsman that have been altered in any way, including the use of any parts and/or other components not specifically approved by Scotsman.

Bins:

All models will fit a standard, 48" wide or wider open top Scotsman Ice Storage Bin. Some examples are:

￿BH900

￿BH1366

￿BH1666

In addition, there may be other bins that can be used, check Scotsman’s sales literature for application information.

Note: Slope-front bins must have an internal baffle. Scotsman’s BH900 has the required baffle. Baffle must be approximately in the position shown in the diagram below.

Baffle

12.0" 4.0"

Side View

BASIC INFORMATION

Model Number

Dimensions

Basic Electrical

Use

Refrigerant

Minimum

Max

 

W x D x H

(volts/Hz/phase)

Condenser

Charge

Circuit

Fuse

 

(w/o bin)

 

 

R-404A

Ampacity

Size

 

 

 

 

 

 

 

CME1356RS-32H

48 ½ “ x 24" x 28

208-230/60/1

ECR411-32A

288 oz

24.9

30

 

 

 

 

 

 

 

CME1356RS-3H

same

208-230/60/3

ECR411-32A

288 oz

15.9

20

 

 

 

 

 

 

 

CME1356RS-6H

same

230/50/1

ERC411-32A

288 oz

24.9

30

 

 

 

 

 

 

 

CME1656RS-32H

same

208-230/60/1

ECR411-32A

288 oz

24.9

30

 

 

 

 

 

 

 

CME1656RS-3H

same

208-230/60/3

ECR411-32A

288 oz

15.9

20

 

 

 

 

 

 

 

CME1656RS-6H

same

230/50/1

ECR411-32A

288 oz

24.9

30

 

 

 

 

 

 

 

* The remote condenser is designed to work in temperatures from -20oF. to 120oF.

Use precharged tubing kits, RTE25 (25’) or RTE40 (40’) or RTE75 (75’). Select the length closest to the needs of the particular installation.

The stacking kit required to place two like model cubers together is: KSCME6-LG-B.The kit required to

connect this ice machine to a central condenser is: RCKCME6GX

March 2010

Page 2

Image 2
Contents CME1356R and CME1656R CME1356R and CME1656R CME1356R and CME1656R Condenser and Ice Machine LayoutsPre-Installation Serial Number PlateLocation & Assembly Bin Control Installation Bin Control Mount BulbStacking Kit KSCME6-LG-B Stacking For The Installer Remote Condenser CME1356R and CME1656R Coupling Instructions Tighten Swivel NutHead Pressure Control Add-On Kit Electrical Drain PlumbingSupply Water Filters Follow all applicable codesAfter Utility Connections Final Check ListComponent Location and Function AutoIQ Controller Freeze Cycle Initial Start UpInitial Start 30 seconds Harvest CycleHow to Adjust the Amount of Water Purge AdjustmentsIf there was a problem during Initial Start Up How To Operate The AutoIQ Controller How The Electronic Cuber Works Refrigeration SystemHigh Voltage Water SystemVolt Technicians Only Freeze Cycle Sequence AutoIQ Controller Operation, Beginning freezeWater Light Refrigeration Technicians Only Harvest Cycle Sequence & Other NotesHarvest LightSanitation and Cleaning To drain reservoir if desired Additional MaintenanceTo Properly Place the Evaporator Covers Additional Maintenance Water Distributors Additional Maintenance Inlet Water Valve Screen Additional Maintenance Ice Sensors, Condenser To Clean the Remote Air Cooled CondenserService Diagnosis Diagnostic Light Analysis Problem or Symptom Possible Cause Probable CorrectionService Diagnosis Service Diagnosis Components TXV March Operational Characteristics CME1356R Operational Characteristics CME1656R Removal and Replacement Water Level Sensor/Float Stem Removal and Replacement AutoIQ Controller Removal and Replacement Water Level Sensor Removal and Replacement Refrigerant Liquid Charging Before Calling for Service Check the followingService Bulletin