Scotsman Ice CME1356R, CME1656R specifications AutoIQ Controller

Page 18

CME1356R and CME1656R

AutoIQ Controller

Indicator Lights:

Cycle Definitions:

￿Bin Full: On when bin is full, goes on and off as ice falls during a harvest cycle.

￿Freeze: On when the unit is in the Freeze cycle, blinks when a freeze cycle is pending.

￿Harvest: On when the unit is in the Harvest cycle.

￿Clean: On when the unit is in the Clean cycle.

￿Off: On when the unit has been switched off, blinks when the machine is preparing to shut off.

￿Water: On when the controller has identified a problem with the water system.

￿Refrigeration: On when the controller has identified a problem with the refrigeration system.

LOW VOLTAGE IN/OUT

 

WATER VALVE

 

HOT GAS VALVE

8

PURGE VALVE TIMER

CONTACTOR COIL

 

STACKING and/or

7

THERMOSTAT

FUTURE USE

6

RESERVOIR & DISCHARGE

5

LINE THERMISTORS

ICE SENSOR

4

ICE SENSOR 3

RESERVOIR WATER

2

LEVEL SENSOR

FACTORY USE 1

￿Freeze: The refrigeration system is operating to remove heat from the evaporators. The compressor, remote fan motor and water pump are ON.

￿Harvest: The refrigeration and water systems are operating to harvest the ice cubes. While the compressor and fan motors are on for the full cycle, the water pump will be off at the beginning and the inlet water valve will switch off before the end.

￿Clean: Water valve opens to fill the reservoir. The Water pump starts. The Clean indicator light is switched ON. A manually initiated rinse cycle flushes the system.

HI VOLTAGE IN/OUT

WATER PUMP

9

PUSH BUTTON

CONTROL SWITCHES

INDICATOR LIGHTS:

BIN FULL

FREEZE

HARVEST

CLEAN

OFF

DIAGNOSTIC LIGHTS:

WATER

REFRIGERATION

May 2001

Page 18

Image 18
Contents CME1356R and CME1656R CME1356R and CME1656R CME1356R and CME1656R Condenser and Ice Machine LayoutsPre-Installation Serial Number PlateLocation & Assembly Bin Control Installation Bin Control Mount BulbStacking Kit KSCME6-LG-B Stacking For The Installer Remote Condenser CME1356R and CME1656R Coupling Instructions Tighten Swivel NutHead Pressure Control Add-On Kit Electrical Drain PlumbingSupply Water Filters Follow all applicable codesAfter Utility Connections Final Check ListComponent Location and Function AutoIQ Controller Freeze Cycle Initial Start UpInitial Start 30 seconds Harvest CycleAdjustments If there was a problem during Initial Start UpHow to Adjust the Amount of Water Purge How To Operate The AutoIQ Controller How The Electronic Cuber Works Refrigeration SystemWater System VoltHigh Voltage Technicians Only Freeze Cycle Sequence AutoIQ Controller Operation, Beginning freezeWater Light Refrigeration Technicians Only Harvest Cycle Sequence & Other NotesHarvest LightSanitation and Cleaning Additional Maintenance To Properly Place the Evaporator CoversTo drain reservoir if desired Additional Maintenance Water Distributors Additional Maintenance Inlet Water Valve Screen Additional Maintenance Ice Sensors, Condenser To Clean the Remote Air Cooled CondenserService Diagnosis Diagnostic Light Analysis Problem or Symptom Possible Cause Probable CorrectionService Diagnosis Service Diagnosis Components TXV March Operational Characteristics CME1356R Operational Characteristics CME1656R Removal and Replacement Water Level Sensor/Float Stem Removal and Replacement AutoIQ Controller Removal and Replacement Water Level Sensor Removal and Replacement Refrigerant Liquid Charging Before Calling for Service Check the followingService Bulletin