Scotsman Ice specifications CME1356R and CME1656R, Condenser and Ice Machine Layouts

Page 3

CME1356R and CME1656R

Condenser and Ice Machine Layouts

ERC411

CONDENSER FINS

 

 

 

 

WARNING

 

 

 

 

 

 

 

 

 

 

 

 

23.54 in

 

 

 

.562 DIA.

 

 

 

59.7 cm

 

MOUNTING

 

 

 

 

 

 

 

 

HOLES (4)

 

 

29.15 in

 

 

 

 

 

 

 

 

 

74.0 cm

 

6.00 in MINIMUM FOR

15.2 cm UTILITY CONNECTIONS

 

.88 DIA. ELECTRICAL

 

29.50 in

 

INLET

 

 

 

74.9 cm

 

 

 

 

DISCHARGE LINE

 

 

 

1/2" MALE CPLG.

 

 

2.75

 

 

 

 

38.47 in

 

 

 

97.7 cm

 

 

 

32.32 in

 

 

 

82.1 cm

 

 

35.72 in

 

 

 

90.7 cm

 

 

 

 

28.07 in

 

 

 

71.2 cm

 

 

 

24.71 in

 

 

 

62.7 cm

 

 

 

 

 

27.56 in

 

7.60 in

 

70.0 cm

 

 

 

2.84 in

19.3 cm

 

 

7.2 cm

 

11.50 in

 

 

 

29.2 cm

 

 

 

14.56 in

 

 

 

36.9 cm

29.19 in

 

 

 

 

 

 

74.1 cm

26.10in

66.3cm

MINIMUM BIN

TOP OPENING

LIQUID LINE

3/8" MALE CPLG.

AIR FLOW

.65 in

1.7 cm

6.00 in

15.2 cm

MINIMUM FOR AIR VENTILATION

 

18.75 in

ICE

PLAN VIEW

47.6 cm

OPENING

 

 

4.20 in

10.15 in

3.81 in

 

10.7 cm

25.8 cm

9.7 cm

 

ICE

OPENING

REMOTE CONDENSER DISCHARGE LINE 1/2" MALE CPLG.

 

WATER INLET

.88 DIA. KNOCKOUT

 

3/8" FLARE

 

ELECTRICAL INLET

 

 

REMOTE CONDENSER

 

2.50 in

 

6.4 cm

LIQUID LINE

 

 

.88 DIA. KNOCKOUT

3/8" MALE CPLG.

 

REMOTE CONDENSER FAN

23.87 in

23.30 in60.6 cm

59.2 cm

 

17.87 in

22.65 in

45.4 cm

 

57.5 cm

 

 

5.87 in

BACK VIEW

14.9 cm

 

2.46 in

DUMP

6.2 cm

15.77 in

VALVE

40.1 cm

DRAIN

 

3/4" F.P.T.

18.67 in

47.4cm

21.77in

55.3cm

May 2001

Page 3

Image 3
Contents CME1356R and CME1656R CME1356R and CME1656R Condenser and Ice Machine Layouts CME1356R and CME1656RSerial Number Plate Pre-InstallationLocation & Assembly Bin Control Installation Mount Bulb Bin ControlStacking Kit KSCME6-LG-B Stacking For The Installer Remote Condenser CME1356R and CME1656R Tighten Swivel Nut Coupling InstructionsHead Pressure Control Add-On Kit Electrical Water Filters Follow all applicable codes PlumbingSupply DrainFinal Check List After Utility ConnectionsComponent Location and Function AutoIQ Controller Harvest Cycle Initial Start UpInitial Start 30 seconds Freeze CycleAdjustments If there was a problem during Initial Start UpHow to Adjust the Amount of Water Purge How To Operate The AutoIQ Controller Refrigeration System How The Electronic Cuber WorksWater System VoltHigh Voltage AutoIQ Controller Operation, Beginning freeze Technicians Only Freeze Cycle SequenceLight Technicians Only Harvest Cycle Sequence & Other NotesHarvest Water Light RefrigerationSanitation and Cleaning Additional Maintenance To Properly Place the Evaporator CoversTo drain reservoir if desired Additional Maintenance Water Distributors Additional Maintenance Inlet Water Valve Screen To Clean the Remote Air Cooled Condenser Additional Maintenance Ice Sensors, CondenserProblem or Symptom Possible Cause Probable Correction Service Diagnosis Diagnostic Light AnalysisService Diagnosis Service Diagnosis Components TXV March Operational Characteristics CME1356R Operational Characteristics CME1656R Removal and Replacement Water Level Sensor/Float Stem Removal and Replacement AutoIQ Controller Removal and Replacement Water Level Sensor Removal and Replacement Refrigerant Liquid Charging Check the following Before Calling for ServiceService Bulletin