Scotsman Ice CME1656R, CME1356R specifications Removal and Replacement Water Level Sensor

Page 41

CME1356R and CME1656R

Removal and Replacement: Water Level Sensor

1.Remove front panel.

2.Push and hold the OFF button. Release it when the machine stops.

3.Trace wire harness from water level sensor to the AutoIQ Controller (#2). Unplug the harness from the controller.

4.Lift the pump and mounting plate up enough to remove the float from the stem.

5.Remove two screws holding the sensor to the pump bracket and lift the sensor up and out of the machine.

6.Reverse to reassemble.

Note: 5 evaporator models have a different float stem from the 6 evaporator machines. Do not mix the two.

￿5 evaporator (CME1356) uses a tan stem

￿6 evaporator (CME1656) uses a brown stem Discharge Line Temperature Sensor

1.Remove front panel, push and release the Off button.

2.Remove top and left side panels.

3.Locate discharge line sensor. It is attached to the discharge line of the compressor, 6" from the compressor discharge port.

4.Un-snap the clip holding the sensor to the discharge line.

5.Trace the sensor wires back to the controller, they are plugged into #5 with the water temperature sensor, and must be replaced with it.

6.Reverse to replace, be sure that the discharge line sensor is 6" up from the compressor discharge port. The discharge line sensor is marked with yellow tape.

Note: Route wires so they do NOT contact the discharge line.

Water Temperature Sensor

Note: This sensor is replaced as a set with the Discharge Temperature Sensor.

1.Remove left front panel.

2.Push and release Off button.

3.Remove 1 plastic bolt and the reservoir cover.

4.Locate water temperature sensor (inserted into pump discharge hose).

5.Pull out to remove.

6.Trace back to AutoIQ Controller, unplug from #5.

7.Remove the Discharge Line temperature sensor.

8.Reverse to reassemble.

Note: Do not push sensor tip in too far. There should be about an 1/8" gap between the tip and the inner wall of the water discharge hose.

March 2003

Page 41

Image 41
Contents CME1356R and CME1656R CME1356R and CME1656R Condenser and Ice Machine Layouts CME1356R and CME1656RSerial Number Plate Pre-InstallationLocation & Assembly Bin Control Installation Mount Bulb Bin ControlStacking Kit KSCME6-LG-B Stacking For The Installer Remote Condenser CME1356R and CME1656R Tighten Swivel Nut Coupling InstructionsHead Pressure Control Add-On Kit Electrical Supply PlumbingDrain Water Filters Follow all applicable codesFinal Check List After Utility ConnectionsComponent Location and Function AutoIQ Controller Initial Start 30 seconds Initial Start UpFreeze Cycle Harvest CycleHow to Adjust the Amount of Water Purge AdjustmentsIf there was a problem during Initial Start Up How To Operate The AutoIQ Controller Refrigeration System How The Electronic Cuber WorksHigh Voltage Water SystemVolt AutoIQ Controller Operation, Beginning freeze Technicians Only Freeze Cycle SequenceHarvest Technicians Only Harvest Cycle Sequence & Other NotesWater Light Refrigeration LightSanitation and Cleaning To drain reservoir if desired Additional MaintenanceTo Properly Place the Evaporator Covers Additional Maintenance Water Distributors Additional Maintenance Inlet Water Valve Screen To Clean the Remote Air Cooled Condenser Additional Maintenance Ice Sensors, CondenserProblem or Symptom Possible Cause Probable Correction Service Diagnosis Diagnostic Light AnalysisService Diagnosis Service Diagnosis Components TXV March Operational Characteristics CME1356R Operational Characteristics CME1656R Removal and Replacement Water Level Sensor/Float Stem Removal and Replacement AutoIQ Controller Removal and Replacement Water Level Sensor Removal and Replacement Refrigerant Liquid Charging Check the following Before Calling for ServiceService Bulletin