Operational Characteristics: CME1356R
Cycle Times (Minutes):
| 0oF. condenser air 70oF. indoor | 90oF. condenser air 90oF. indoor |
| air, 55oF. water | air, 70oF. water |
Freeze | 11 ½ - 12 ½ | 16 - 17 |
|
|
|
Harvest | 3 | 2 ½ |
|
|
|
|
|
|
System Pressures (PSIG)
| 70oF. condenser air 70oF. indoor | 90oF. condenser air 90oF. indoor | |
| air, 55oF. water | air, 70oF. water | |
Suction: End of Freeze | 29 - 31 | 30 | - 32 |
|
|
|
|
Suction: Peak in Harvest | 70 - 80 | 95 | - 105 |
|
|
| |
Discharge: 5 minutes into Freeze | 230 - 250 | 275 - 285 | |
|
|
| |
Discharge: Minimum in Harvest | 80 | 100 | |
|
|
|
|
|
|
|
|
Number of Evaporators:
5
Refrigerant Charge
288 ounces of
Typical Compressor Amps, single phase
freeze 14 - 15
harvest 17 - 18
Typical Compressor Amps, three phase
freeze 8 - 9
harvest 10 - 11
Typical Harvest Ice Weight
16.0 lb
Superheat
The TXV will control a nominal superheat point that can vary unit to unit from 11oF. to 17oF.
While controlling that point the superheat can also range + or - 4oF. without affecting performance.
Hi Pressure Control - Automatic Reset
Hi Pressure Cut Out - 450 PSIG
Hi Pressure Cut In - 350 PSIG
Headmaster Valve
Setting is 240 PSIG